Search:

Type: Posts; User: bohncoils

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    8
    Views
    745

    For as small as Ft. Wayne is (relatively...)...

    For as small as Ft. Wayne is (relatively...) there are some larger mechanical contractors up there, very quality outfits too. GL!
  2. Replies
    13
    Views
    1,156

    Yup -- pain in the a**. Why can't they make it...

    Yup -- pain in the a**. Why can't they make it easy like Hoshi and Scotsman?
  3. Replies
    13
    Views
    1,156

    not answering your question -- but we were...

    not answering your question -- but we were experiencing 3+ hour delays in getting a call back from tech support last week. and we're a FAS. perhaps some guys on vacation?
  4. Replies
    28
    Views
    1,732

    Manitowoc's new Kool aire line utilizes 410a....

    Manitowoc's new Kool aire line utilizes 410a. Zero zone also has done some med temp and low temp cases as 410a. May catch on..
  5. Replies
    27
    Views
    2,490

    I've dealt with fm, facility source, Cbre,...

    I've dealt with fm, facility source, Cbre, service channel, etc for about four yearsnow. In the beginning I hated them but as time goes on you get to learn their procedures and develop contacts to...
  6. Replies
    4
    Views
    496

    From my experience almost all major market chains...

    From my experience almost all major market chains employ some sort of in house refer staff. Sometimes they may be pm techs only at small chains.
  7. If you strike out with Anthony try schott gemtron...

    If you strike out with Anthony try schott gemtron out of Vincennes indiana. They are great for custom stuff.
  8. Alternative is to do the supco or Sporlan I can't...

    Alternative is to do the supco or Sporlan I can't remember which conversion chart to find another id different length to serve same capacity.
  9. Replies
    2
    Views
    532

    Not familiar but have you tried zero zones tech...

    Not familiar but have you tried zero zones tech support? They really great.. I can give you a name of the guru there if you've struck out already.
  10. Very few 502s around here, most everyone has...

    Very few 502s around here, most everyone has converted to 408a. I'd say mistake.
  11. Anecdotally I've had a lot tighter control...

    Anecdotally I've had a lot tighter control utilizing a Honeywell vp8000 or an equivalent as opposed to tranes oem baysens controls.
  12. Large in Ohio for construction. Appears they are...

    Large in Ohio for construction. Appears they are trying to infiltrate indiana.
  13. Replies
    40
    Views
    3,557

    Ironic timing.., Manitowoc announced today they...

    Ironic timing.., Manitowoc announced today they are utilizing 410a in their new line of ice machines..
  14. Thread: Info On JLL

    by bohncoils
    Replies
    32
    Views
    3,658

    Just for clarification purposes.. Cbre got jcp...

    Just for clarification purposes.. Cbre got jcp not Jll.
  15. Replies
    14
    Views
    2,434

    *cough* trane *cough*

    *cough* trane *cough*
  16. Replies
    10
    Views
    1,550

    Ditto, we have probably installed 200 Carrier...

    Ditto, we have probably installed 200 Carrier micro channel coil units in the last 3 years, probably 20 leakers. Carrier claims to not have any problems, lol.
  17. Replies
    1
    Views
    596

    Link for those who haven't got sales sheets...

    Link for those who haven't got sales sheets yet...

    http://www.emersonclimate.com/en-us/Products/Condensing_Units/Scroll/Pages/Copeland_Scroll_FFAP_Condensing_Unit.aspx
  18. Replies
    8
    Views
    1,677

    ServiceNet is a PITA to deal with.

    ServiceNet is a PITA to deal with.
  19. Replies
    16
    Views
    2,608

    Price out a helicopter, if you get the job,...

    Price out a helicopter, if you get the job, great, if you don't you're probably better off.
  20. Replies
    7
    Views
    3,355

    I'm HVAC Excellence certified, and have really...

    I'm HVAC Excellence certified, and have really seen no benefits. After I became certified, I never heard a word from HVAC Excellence.

    I am in the process of getting ready to take NATE...
  21. Replies
    93
    Views
    24,844

    Not disagreeing with your post, but you just...

    Not disagreeing with your post, but you just described most if not all mechanical contractors :) Kind of the nature of the beast, feast or famine.
  22. Replies
    27
    Views
    3,330

    I can only speak for the market we work in -- but...

    I can only speak for the market we work in -- but PremierLink has been abandoned. The new EMS company is Gridpoint -- great to work with when you do get their roll out.
  23. Replies
    6
    Views
    1,091

    Concur. Although relatively new to ductless...

    Concur. Although relatively new to ductless splits, we've installed probably 15-20 Fujitsu's over the last 3 years and have had 0 problems. Never any install problems, never any call back problems.
  24. Replies
    17
    Views
    1,843

    Question answered. Gotcha. In my area, American...

    Question answered. Gotcha. In my area, American Standard offers up to 10-ton 230v 3ph, but nothing bigger. I understand now :)
  25. Replies
    17
    Views
    1,843

    I gotta ask, why change to 407 right now? Dry 22...

    I gotta ask, why change to 407 right now? Dry 22 units are available like crazy, atleast around the midwest. R-22 prices aren't "that" bad right now, relatively. I have yet to have a customer, albiet...
  26. Replies
    15
    Views
    2,496

    We've ran into quite a few of these. I've got...

    We've ran into quite a few of these. I've got three invoices on my desk currently where customers refuse to pay for our fix, stating that it should be under warranty. Frustrating.
  27. Replies
    47
    Views
    4,595

    I'm in the midwest, prime area for economizers....

    I'm in the midwest, prime area for economizers. They are theoretically beneficial, as explained by others a few posts back not only do they provide free cooling, but provide outside air for IAQ....
  28. Most of my technicians have went to the CSR...

    Most of my technicians have went to the CSR school, as well as Servend classes in Sellersburg -- nothing but compliments. I'd really gauge it on how much you work on their machines though. If you...
  29. Replies
    41
    Views
    12,829

    The company I worked for is geared the same way...

    The company I worked for is geared the same way -- service everything in the restaurant. however, we do handle dish machines and coffee machines also. Just out of sheer curiosity, why do yo not? I...
  30. Replies
    16
    Views
    2,996

    Seen quite a few K-Mart roofs, and I've never...

    Seen quite a few K-Mart roofs, and I've never seen a chiller. All package RTUs.
  31. Replies
    6
    Views
    1,364

    They ditched Marvel quite a few years ago (3-4?)...

    They ditched Marvel quite a few years ago (3-4?) around here. They now use Sanyo Biomedical.
  32. Replies
    11
    Views
    1,275

    If you're going to recover anyway, why not...

    If you're going to recover anyway, why not nitrogen?
  33. Thread: best books

    by bohncoils
    Replies
    5
    Views
    762

    Get signed up for Trane's Comfortsite and read...

    Get signed up for Trane's Comfortsite and read their IOM and service manuals, some pretty good explanations in there of operations.
  34. Replies
    24
    Views
    3,730

    A DuPont guy came into my company and touted MO99...

    A DuPont guy came into my company and touted MO99 as a complete drop-in, no oil change, no flush necessary AT ALL. Went to a seminar put on by National Refrigerants(NRI) and they claimed that there...
  35. Replies
    9
    Views
    1,214

    Our local Carrier distributor does Sanyo in my...

    Our local Carrier distributor does Sanyo in my area. This may just be local, but you may try your Carrier distributor.
  36. Replies
    4
    Views
    1,657

    Anthony is a challenge to deal with. I can tell...

    Anthony is a challenge to deal with. I can tell you now, make sure you have their BM#, dimensions, what side its hinged, etc. Overkill all your information before you call.
  37. Replies
    8
    Views
    927

    If you ever decide to drop south to Indy, drop a...

    If you ever decide to drop south to Indy, drop a line.
  38. Replies
    7
    Views
    3,209

    Hobart guards their literature like gold, good...

    Hobart guards their literature like gold, good luck.
  39. Dry 22 units are all over here. Gone through 4-5...

    Dry 22 units are all over here. Gone through 4-5 of them this summer. Carrier distributor, Bryant distributor, and the cheapos all have them. Trane and Lennox do not, here anyway.
  40. I'm amazed every day Ice-O-Matic stays in...

    I'm amazed every day Ice-O-Matic stays in business. Maybe its just around here, but it seems as if no restaurant chains use them, maybe one in a hundred.