  2. Replies
    4
    Views
    334

    what type of ducts? as long as not flex you...

    what type of ducts? as long as not flex you should be good just running the system fan for a day to dry things out.
  3. Thread: Lennox ac

    by t527ed
    Replies
    6
    Views
    328

    blower coil or using a furnace? only way you will...

    blower coil or using a furnace? only way you will hit 16 seer is with a v drive blower.
    upflow, downflow or horizonal??
  4. Replies
    10
    Views
    490

    cooked mine upside down the whole time, perfect...

    cooked mine upside down the whole time, perfect and juicy. :grin2:
  5. a fairly small percentage of the ones we have...

    a fairly small percentage of the ones we have installed. as long as they had the new heat ex installed during the inspection program or are the G21 models most of them are still going strong.

    main...
  6. Replies
    128
    Views
    5,796

    some mags are just tough to load to capacity....

    some mags are just tough to load to capacity.
    google Butler Creek mag loader
  7. this will work most of the time.

    this will work most of the time.
  8. why?? we have many pulse furnaces still going...

    why??
    we have many pulse furnaces still going strong and pass routine pressure tests.
    OP comes here with an obvious zoning problem and gets stomped on.

    OP get someone in there that understands...
  9. Replies
    2
    Views
    305

    that system is the ideal situation for a mister...

    that system is the ideal situation for a mister style humidifier.
    we usually install them on the a/c coil cabinet with an extension tube to put the spray nozzle below the coil.
  10. Thread: Condesate Leak!

    by t527ed
    Replies
    27
    Views
    1,072

    probably a crack in the inducer that tightening...

    probably a crack in the inducer that tightening the clamp is causing to open up.

    common?? no but stuff happens. no way a plugged drain would cause a leak that high in the system.
    let them replace...
  11. Replies
    8
    Views
    447

    never heard of a code like that, been installing...

    never heard of a code like that, been installing in NJ for 45 years.

    that 2" pipe WILL freeze.
  12. Replies
    79
    Views
    3,758

    517721 Depending on the weather PX4. .40...

    517721

    Depending on the weather
    PX4. .40 subcompact
    Sig P230. .380
  13. it was gone in the mid 70's for sure. we sold...

    it was gone in the mid 70's for sure. we sold them until they went away then went to Bryant until Carrier bought them.
    sold Bryant for probably 6-7 years before going to Lennox in 81-82, been with...
  14. pretty sure the old original westinghouse company...

    pretty sure the old original westinghouse company went out of business in the mid to late 70's.
    we were selling them at the time and they just went away.

    furnace is way over the 30 yr mark, plan...
  15. Replies
    14
    Views
    663

    to add to your problems the vent going into the...

    to add to your problems the vent going into the garage violates code. as long as there is a garage door it cannot have any duct work that ties into the house system.

    maybe a window unit or mini...
  16. Replies
    14
    Views
    663

    one problem i see is if you are exhausting air...

    one problem i see is if you are exhausting air from the garage it will be replaced with outdoor air that could be more humid, causing more condensation problems.
  17. Replies
    14
    Views
    663

    how big is the piece of equipment and how much...

    how big is the piece of equipment and how much air are you looking to move?
    maybe something like a kitchen exhaust hood over the equipment ducted out a side wall.
  18. it is not a wiring issue, it is in the setup...

    it is not a wiring issue, it is in the setup menu.

    i never liked auto changeover and always set them to manual.
  19. get another price on labor to replace the HX, G26...

    get another price on labor to replace the HX, G26 is pretty easy to do. :.02:
  20. where is the duct system? if it is an attic...

    where is the duct system?
    if it is an attic system another benefit besides air filtration would be preventing condensation from forming in the cold ducts.
    a thermostat with a circulate setting for...
  21. Replies
    3
    Views
    303

    flaring block if under 3/4"

    flaring block if under 3/4"
  22. Replies
    21
    Views
    1,216

    :ditto:

    :ditto:
  23. Replies
    6
    Views
    484

    pull the cold air off the floor. :.02:

    pull the cold air off the floor. :.02:
  24. Replies
    17
    Views
    1,005

    if the manual states it must be installed as...

    if the manual states it must be installed as direct vent then that's what needs to be done.
    we have NEVER installed a 90+ furnace as a single pipe system, i don't want contaminated house air being...
  25. Replies
    6
    Views
    321

    if they are going to use filter grills then make...

    if they are going to use filter grills then make sure ALL return ducting back to furnace is 100% air tight. if not you will be pulling dirt into system after filter.
    i prefer to use filter rack or...
  26. Replies
    11
    Views
    531

    if its a single stage unit and w915 jumper on...

    if its a single stage unit and w915 jumper on board is in place it will run blower at 2nd stage settings no matter what Y terminal it is wired to.
  27. Replies
    39
    Views
    1,553

    nobody is going to rake him over the coals for...

    nobody is going to rake him over the coals for doing it.

    EVERYONE is going to rake him over the coals for talking about doing it. :whistle:
  28. Replies
    7
    Views
    433

    what tonnage?

    what tonnage?
  29. Replies
    5
    Views
    318

    water was leaking out of t instead of backing up...

    water was leaking out of t instead of backing up into pan to trip safety.
    drain lines get dirty and need to be maintained, yours is undersized and should be replaced with full size 3/4" pvc.
  30. Replies
    22
    Views
    1,502

    to use a 13 seer unit with an old cap tube evap...

    to use a 13 seer unit with an old cap tube evap coil it will have to be grossly overcharged to get the liquid pressure up high enough to feed thru the cap tube.
    it will work but it won't be right...
  31. in over 40 years i have never seen them for...

    in over 40 years i have never seen them for residential use.
    a true split system would be much more efficient.
  32. it may work with no problems, could be nothing...

    it may work with no problems, could be nothing but a big headache.
    depending on the system, coil location, ease of changing line set etc.. smart money would be replacing complete system.
  33. Replies
    6
    Views
    407

    could not find exact model # but every amana...

    could not find exact model # but every amana model with a 5 in it was a 5 ton unit.

    any #s you can read on compressor?
  34. i don't understand why you keep referring to...

    i don't understand why you keep referring to Trane as a "premium" brand ???

    you may have paid a lot for it but price alone does not equal quality.
  35. any part on that system could fail, it's a...

    any part on that system could fail, it's a machine.
    not worth worrying about.
  36. #1

    #1
  37. Lennox had some weird serial #s up until the...

    Lennox had some weird serial #s up until the 70's, that looks like one of them.

    i would plan on changing the lines.
  38. Replies
    128
    Views
    5,796

    i sent a loose dog on his way yelping the same...

    i sent a loose dog on his way yelping the same way once.
  39. as the installer and the guy who has to go back...

    as the installer and the guy who has to go back and fix it when it breaks i have always been in the habit of looking for stuff that could be a problem.
    lines touching and rubbing through each other...
  40. Replies
    4
    Views
    349

    package unit will be fully charged from factory....

    package unit will be fully charged from factory.
    needs to be checked on start up in case of a leak.
  41. Replies
    4
    Views
    349

    most units ship with charge for 15' of lineset...

    most units ship with charge for 15' of lineset and matching coil.
    installer must balance charge at start up.
  42. Replies
    1
    Views
    247

    with what it would cost to run the well it would...

    with what it would cost to run the well it would never pay for itself unless you are already watering landscape as much as a/c runs.

    it would not harm a/c as long as you are not restricting air...
  43. contact Trane directly as the consumer and give...

    contact Trane directly as the consumer and give them that argument.
    stop back and let us know how you make out.
    i don't disagree with you and i really don't like Trane equipment so i'm not...
  44. did you close off the vent when you sucked out...

    did you close off the vent when you sucked out with shop vac?
  45. installer should have checked for any rub points...

    installer should have checked for any rub points at start up.

    Trane's obligation is to provide a replacement part.
  46. Replies
    5
    Views
    384

    low speed for heat, high speed for cooling. it...

    low speed for heat, high speed for cooling. it starts on whatever speed it is going to run on.
  47. Replies
    12
    Views
    866

    change the filter/ drier again and cut back on...

    change the filter/ drier again and cut back on the cap tube.
    make sure the cap tube is clear where you cut it back to. had a true beer box wax up the cap tube all the way to the evap.
  48. Replies
    33
    Views
    5,572

    are you required to have the 120v service outlet...

    are you required to have the 120v service outlet on every job now? only time we are required to have it is new construction or if house did not have A/C before.
  49. Replies
    10
    Views
    516

    in 40 years we have never anchored a unit to the...

    in 40 years we have never anchored a unit to the pad, that's what gravity is for. :whistle:

    some codes do require it depending on where you live, give your location and maybe someone local will...
  50. Replies
    7
    Views
    592

    Lennox CBX25 blower coils 52.5" for 5 ton, ...

    Lennox CBX25 blower coils 52.5" for 5 ton, shortest Lennox makes
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event