Search:
Type: Posts; User: hw chiller man
Search: Search took 0.02 seconds.
-
10-22-2012, 09:12 PM
Thread: Chiller Failure
by hw chiller man- Replies
- 26
- Views
- 5,760
It was rebuilt, with eddy current testing, both...
It was rebuilt, with eddy current testing, both by York. York gave a 90 day warranty knowing the chiller hardly runs and this satisfied the customer. As you can see its been running for 7 years now...
-
10-22-2012, 03:35 PM
Thread: Chiller Failure
by hw chiller man- Replies
- 26
- Views
- 5,760
Here are some pictures of different chiller...
Here are some pictures of different chiller failures319641319651319661319671
-
04-11-2011, 08:22 PM
Thread: Replacement for copper
by hw chiller man- Replies
- 8
- Views
- 866
Schedule 10 stainless, I got approval to use from...
Schedule 10 stainless, I got approval to use from Trane on an air cooled remote evaporator installation. Project did not happen. the pipe was going to be welded and cleaned as required. The weight is...
-
09-16-2010, 08:09 PM
Thread: UA QUESTION
by hw chiller man- Replies
- 36
- Views
- 1,931
This may or may not help you AC. I officially...
This may or may not help you AC. I officially retired from the UA on January 1, 2010. I received all my pension money and rolled it into an RRSP as required under Canadian law. I now have control...
-
03-01-2010, 02:01 PM
Thread: York Ycas Chiller Failures
by hw chiller man- Replies
- 153
- Views
- 27,106
Tried to send the form but was rejected by your...
Tried to send the form but was rejected by your server
-
09-03-2009, 05:05 PM
Thread: York Ycas Chiller Failures
by hw chiller man- Replies
- 153
- Views
- 27,106
Hi Abs Would you be kind enough to email me...
Hi Abs
Would you be kind enough to email me the form, I tried getting it
from JCI directly, no luck. My email is Email Address Removed
best regards..........wayne -
06-28-2009, 09:54 PM
Thread: McQuay Chiller Low Temp Shutdown
by hw chiller man- Replies
- 10
- Views
- 958
Thanks for the reply. I don't have a diagrahm in...
Thanks for the reply. I don't have a diagrahm in front of me but I thought the unload signel came directly from the compressor controller. This is a Microtech II retrofit.
-
06-28-2009, 06:06 PM
Thread: McQuay Chiller Low Temp Shutdown
by hw chiller man- Replies
- 10
- Views
- 958
Low evap temp
Low evap temp
-
06-28-2009, 03:42 PM
Thread: oil level switch-30GX chiller
by hw chiller man- Replies
- 4
- Views
- 819
You can get the most oil out of the vessel by...
You can get the most oil out of the vessel by closing the valve upstream of the internal oil filter and front seating the service valve upstream of the inline filter. Remove the oil from the service...
-
06-28-2009, 03:26 PM
Thread: oil level switch-30GX chiller
by hw chiller man- Replies
- 4
- Views
- 819
Be careful with that switched. I replaced one...
Be careful with that switched. I replaced one this week because we had oil at the schraeder on the bottom of the vessel but the switch would not make. Replaced switch, inspected old one and it worked...
-
06-28-2009, 03:20 PM
Thread: McQuay Chiller Low Temp Shutdown
by hw chiller man- Replies
- 10
- Views
- 958
Set point is 44F Flow is at design Not sure on...
Set point is 44F
Flow is at design
Not sure on liquid level
Sensor reads correctly when the chiller is running properly and when this issue happens.
Perhaps I didn't explain thoroughly. As the... -
06-28-2009, 06:58 AM
Thread: McQuay Chiller Low Temp Shutdown
by hw chiller man- Replies
- 10
- Views
- 958
McQuay Chiller Low Temp Shutdown
We have a site with two McQuay PEH067 chillers. The micros were changed out a few years ago by McQuay service and have operated flawlessly since then. Recently one of the chillers started shutting...
-
06-15-2009, 09:37 PM
- Replies
- 22
- Views
- 1,121
Thanks for the info
Thanks for the info
-
06-14-2009, 09:58 PM
- Replies
- 22
- Views
- 1,121
I remember that picture. Also thought the Vacinol...
I remember that picture. Also thought the Vacinol was great. Mine always seemed to crack around the plastic casing and the numbers would wash off. The idea was great, the apparatus was not so good,...
-
06-14-2009, 06:46 PM
- Replies
- 22
- Views
- 1,121
Is this the picture with the wet bulb indicator...
Is this the picture with the wet bulb indicator attached to the chiller?
-
06-14-2009, 05:57 PM
- Replies
- 22
- Views
- 1,121
I believe the 5000 microns comes from the days...
I believe the 5000 microns comes from the days when York and Carrier used a wet bulb indicator to measure vacuum. If I remember correctly, we tried to achieve a reading of -12F (methyl alcohol)...
-
05-09-2009, 07:28 PM
- Replies
- 5
- Views
- 504
Haven't seen that York in over a year, they...
Haven't seen that York in over a year, they stopped paying there bills and we were outa there like mice jumping off a sinkin ship. I thought for sure you guys were doing it.
The McQuay is no big... -
04-28-2009, 05:08 PM
- Replies
- 5
- Views
- 504
That was indeed the problem. I went to a...
That was indeed the problem. I went to a different site to check that line and saw the 250 followed by 0000 which is the actual current. Went to my site and there was no 250, all 0's, I entered the...
-
04-28-2009, 06:21 AM
- Replies
- 5
- Views
- 504
Thanks Rick I will try that today.
Thanks Rick
I will try that today. -
04-27-2009, 06:37 PM
- Replies
- 5
- Views
- 504
HELP!!! Microtec II motor current troubles
I installed a Microtec II panel last winter on a PEH 087 chiller. The weather has finally warmed so that the micro can be comissioned. All operation appears satisfactory except for the motor current...
-
11-10-2008, 05:23 PM
Thread: McQuay Microtech 100
by hw chiller man- Replies
- 5
- Views
- 735
I believe the panel is 1996 vintage according to...
I believe the panel is 1996 vintage according to the serial number.
-
11-08-2008, 12:36 PM
Thread: McQuay Microtech 100
by hw chiller man- Replies
- 5
- Views
- 735
I'll have to check the year on monday, I removed...
I'll have to check the year on monday, I removed the model and serial number plate and installed it on the new micro. I will break it down as I have already stated but I want to sell all components...
-
11-08-2008, 10:40 AM
Thread: McQuay Microtech 100
by hw chiller man- Replies
- 5
- Views
- 735
McQuay service quoted to do the job of installing...
McQuay service quoted to do the job of installing the new panel and was offering a credit of $3000.00 for the old panel. I'd say $500 plus shipping costs would be a good starting point. I'll remove...
-
11-04-2008, 09:11 PM
Thread: McQuay Microtech 100
by hw chiller man- Replies
- 5
- Views
- 735
McQuay Microtech 100
This panel was recently removed from a PEH 087 chiller and was completely operational. Best offer
-
11-01-2008, 12:58 AM
Thread: Help with McQuay touch screen
by hw chiller man- Replies
- 4
- Views
- 523
Thanks Abs, I will be back at the site on monday...
Thanks Abs, I will be back at the site on monday and give it a try. The only calibration that I could see was the buttons to the bottom right of the screen....but they all seemed to only deal only...
Results 1 to 25 of 323