I have replaced check valves in Trane coils to a...
I have replaced check valves in Trane coils to a spring loaded valve to prevent a banging or load knocking sound coming from the air handler in the heat mode before. Also just a couple days ago we...
-
03-01-2009, 01:46 PM
Thread: Heat Pump + Snow = ?
by dano- Replies
- 21
- Views
- 942
Because I see a lot of them driving to work in...
Because I see a lot of them driving to work in the A.M and they look to operate just like yours. Some brand frost from the bottom up and some from the middle out, it all depends how they feed...
-
03-01-2009, 01:31 PM
Thread: Question for the PROS
by dano- Replies
- 41
- Views
- 1,260
We have Certified Energy Raters in Florida that...
We have Certified Energy Raters in Florida that have to commissioned even replacement systems starting in May and duct leakage rate, before you can get final inspection. The cost of business will go...
-
03-01-2009, 01:21 PM
Thread: Heat Pump + Snow = ?
by dano- Replies
- 21
- Views
- 942
Looks like normal operation from that picture....
Looks like normal operation from that picture. The frost lines are determined by where the refrigerant feeds into the coil and how much heat it's picking up.
Where there is no frost is where the... -
03-01-2009, 11:31 AM
Thread: Apparent Defrosting Issue - Any Insight??
by dano- Replies
- 24
- Views
- 1,301
Now the boards are set by coil termination temp...
Now the boards are set by coil termination temp and no run time sensor check settings. You only have coil temp termination. 50/60/70 on some models. Trane units will average 10 defrost cycles and...
-
03-01-2009, 10:52 AM
Thread: Question for the PROS
by dano- Replies
- 41
- Views
- 1,260
Sounds like they need to check your static...
Sounds like they need to check your static pressure on the duct system, that is the only way to know if the duct system is correct or not. You design a duct system per the specs, of the a/c system...
-
03-01-2009, 10:42 AM
Thread: disappointed in NATE techs
by dano- Replies
- 56
- Views
- 2,502
Does the vibration occur all the time in the heat...
Does the vibration occur all the time in the heat mode? Or just sometimes? If it's after defrost you can change the defrost control to a soft shift model. This will bring on the condenser sooner to...
-
03-01-2009, 10:12 AM
Thread: Heat Pump + Snow = ?
by dano- Replies
- 21
- Views
- 942
Also I'm assuming that if you live in snow...
Also I'm assuming that if you live in snow country that the condenser unit is raised off the ground three feet?
-
03-01-2009, 10:10 AM
Thread: Heat Pump + Snow = ?
by dano- Replies
- 21
- Views
- 942
If it's keeping temp setting in the house don't...
If it's keeping temp setting in the house don't worry about it, it's normal to frost up to near 80-90% of the coil. Not knowing if it's a demand defrost control or not it's hard to say how much frost...
-
03-01-2009, 09:56 AM
Thread: Question for the PROS
by dano- Replies
- 41
- Views
- 1,260
Do you have a gas furnace as one of your...
Do you have a gas furnace as one of your auxiliary heat sources or is it electric? With a 3800 sg ft house it's hard to believe that you have to much air flow with a 5 ton system. The 3800 sq ft is...
-
03-01-2009, 09:10 AM
Thread: OK for Heat Pump to run continuously
by dano- Replies
- 7
- Views
- 996
No way, I was just repeating what I have had to...
No way, I was just repeating what I have had to tell customers all winter long due to our unusually cold winter so far.
" Why is my Heat pump running"- Because it can't walk.
Why does my air... -
03-01-2009, 09:03 AM
Thread: Noisy Rheem Heat Pump
by dano- Replies
- 20
- Views
- 3,283
The condenser motor support grille on RQNJA...
The condenser motor support grille on RQNJA package units is not strong enough and will cause noise especially in the heat mode when unit builds frost. Order the new replacement grille for motor and...
-
03-01-2009, 08:35 AM
Thread: OK for Heat Pump to run continuously
by dano- Replies
- 7
- Views
- 996
Call me when it stops running.
Call me when it stops running.
-
03-01-2009, 08:31 AM
- Replies
- 14
- Views
- 2,287
It sounds like the tubing near the TXV valve in...
It sounds like the tubing near the TXV valve in the coil is vibrating against the coil. They should insulate the tubing near the TXV and strap or support it better, this might help. The over sized...
-
12-24-2008, 10:08 AM
Thread: Noisy Rheem Heat Pump
by dano- Replies
- 20
- Views
- 3,283
Sorry I thought we were talking about a split...
Sorry I thought we were talking about a split system. This model indicates a package unit. 13 seer.
We have had issues with complaints on those units that it sounds like a helicopter when it... -
12-24-2008, 09:50 AM
Thread: Noisy Rheem Heat Pump
by dano- Replies
- 20
- Views
- 3,283
I hope that works out. This will help if it is in...
I hope that works out. This will help if it is in deed the Defrost cycle causing the noise or start up. If it continues to be a problem. Take more notes on when it happens as far as weather...
-
12-24-2008, 09:39 AM
- Replies
- 38
- Views
- 1,614
Sounds like the old 2.5 was over sized also? You...
Sounds like the old 2.5 was over sized also? You must of had problems before and did not know. Go to www.rheem.myvirtualhvac.com and find out what size unit you should have.
Make sure what ever is... -
12-19-2008, 11:24 PM
Thread: Lennox HP- Hard Start- Need Advice
by dano- Replies
- 24
- Views
- 2,212
Adjust the lock out temp for a higher temp..I...
Adjust the lock out temp for a higher temp..I hope we are capalable of doing that. The shuttle just landed.
3 Degree's is not reasonable. -
12-19-2008, 11:17 PM
Thread: Lennox HP- Hard Start- Need Advice
by dano- Replies
- 24
- Views
- 2,212
All Trane boards are considered soft shift....
All Trane boards are considered soft shift. Meaning they bring on the condenser fan to lower the pressure before they shift the valve...Aren't they nice....
This stops the swishing noise... -
12-19-2008, 11:11 PM
Thread: Lennox HP- Hard Start- Need Advice
by dano- Replies
- 24
- Views
- 2,212
I was born in West Des Moines, live Florida now...
I was born in West Des Moines, live Florida now it's 82 today>>>>>>
-
12-19-2008, 10:57 PM
Thread: Trane XL13i Heat pump?
by dano- Replies
- 8
- Views
- 957
I hope so....
I hope so....
-
12-19-2008, 10:51 PM
Thread: Noisy Rheem Heat Pump
by dano- Replies
- 20
- Views
- 3,283
It can only be a RPN_ 30JAZ if it's a 2.5 ton 15...
It can only be a RPN_ 30JAZ if it's a 2.5 ton 15 seer matched with a RHL-HM3617JA air handler.
That was a Rheem fishing trip in Costa Rica so I hope I can help. -
12-19-2008, 10:45 PM
Thread: Noisy Rheem Heat Pump
by dano- Replies
- 20
- Views
- 3,283
Thanks...It was out of site!@!
Thanks...It was out of site!@!
-
12-19-2008, 10:39 PM
Thread: Trane XL13i Heat pump?
by dano- Replies
- 8
- Views
- 957
I'm sorry for I have sinned...I did not read your...
I'm sorry for I have sinned...I did not read your complete blog. It is a heat pump but the model# indicates a XL16i not XL13i. If so it's 2-stage R-410A refrigerant Heat Pumper...
-
12-19-2008, 10:19 PM
Thread: Trane XL13i Heat pump?
by dano- Replies
- 8
- Views
- 957
Xl13i could be a heat pump or a cool only. This...
Xl13i could be a heat pump or a cool only. This is only the style of unit not the model number. The XL13i is a single stage unit. Not knowing how many heat stages you need need it could mean 2H/1C or...