Search:
Type: Posts; User: hvacjamie
Search: Search took 0.01 seconds.
-
04-07-2012, 05:08 PM
Thread: Refrigerant Oils
by hvacjamie- Replies
- 6
- Views
- 571
:ditto:
:ditto:
-
04-07-2012, 04:59 PM
Thread: Hoshi bin thermo
by hvacjamie- Replies
- 2
- Views
- 453
Crazy. We had the exact same thing happen this...
Crazy. We had the exact same thing happen this week at a McDonald's location.
-
03-17-2012, 07:35 PM
Thread: Possible restriction or bad compressor
by hvacjamie- Replies
- 56
- Views
- 2,864
solenoid?
solenoid?
-
09-27-2011, 03:30 PM
Thread: trouble with ice o matic machine
by hvacjamie- Replies
- 17
- Views
- 992
the timer is really small, but there is also a...
the timer is really small, but there is also a low pressure initiate switch that makes in order to activate the timer sequence on some models. If that were bad, or the timer, you would get the...
-
09-23-2011, 05:29 PM
- Replies
- 21
- Views
- 1,640
if it's unable to reach a specific humidity...
if it's unable to reach a specific humidity level, it will cycle cooling well past it's cooling setpoint. Probably cutting out in the evening when trying to do this?
-
07-31-2011, 06:10 PM
Thread: hobart model am14c dishwasher
by hvacjamie- Replies
- 2
- Views
- 1,407
when you say energized, do you mean it trips? or...
when you say energized, do you mean it trips? or is there just no power coming off the switch?
-
07-27-2011, 09:24 PM
Thread: Which meter
by hvacjamie- Replies
- 49
- Views
- 4,120
really? I haven't had any problem with that. I...
really? I haven't had any problem with that. I have a few meters, but this is my main go-to all day.
-
07-27-2011, 09:16 PM
Thread: water heat 2-zone system issue
by hvacjamie- Replies
- 10
- Views
- 465
tell the plumber that your zones are gravity...
tell the plumber that your zones are gravity feeding.
-
07-27-2011, 09:11 PM
Thread: water heat 2-zone system issue
by hvacjamie- Replies
- 10
- Views
- 465
if you shock that boiler and crack it, you are...
if you shock that boiler and crack it, you are not going to be happy.
-
07-27-2011, 09:01 PM
- Replies
- 13
- Views
- 3,205
did you run a vac on this system before charging?
did you run a vac on this system before charging?
-
07-27-2011, 07:50 PM
Thread: Garmin vs TomTom
by hvacjamie- Replies
- 26
- Views
- 1,899
I have used Garmin for years, but wish I could...
I have used Garmin for years, but wish I could get the Mr. T voice like the Tom Tom.
-
07-27-2011, 07:47 PM
Thread: Which meter
by hvacjamie- Replies
- 49
- Views
- 4,120
fluke 902. I had the fieldpiece, but the thing...
fluke 902.
I had the fieldpiece, but the thing was beeping the entire time it is put to power. it was annoying as heck. it also broke on the clamp part after a couple of months. the temp input... -
07-27-2011, 07:43 PM
Thread: Widely accepted "best" multimeter?
by hvacjamie- Replies
- 50
- Views
- 6,336
pretty happy with my flukes. i use the 902 mainly.
pretty happy with my flukes. i use the 902 mainly.
-
07-27-2011, 07:34 PM
- Replies
- 13
- Views
- 3,205
what are the actual pressures?
what are the actual pressures?
-
07-27-2011, 07:22 PM
Thread: cheap restaurant owners
by hvacjamie- Replies
- 6
- Views
- 565
hahaha that's funny. good thing they saved it....
hahaha that's funny. good thing they saved it. (so you could rebuild it for more than a new one)
-
how are the other circuits' defrost cycles...
how are the other circuits' defrost cycles coinciding? once the temp climbs, does it stay in that range indefinitely or swing around?
-
07-26-2011, 07:33 PM
- Replies
- 9
- Views
- 2,110
We service a church that has about 8 mini's...
We service a church that has about 8 mini's controlled by one commercial stat. Once a call is initiated, each mini then energizes from individual relays in an electrical room. Then they react to...
-
07-25-2011, 07:57 PM
Thread: I cannot FIND THIS LEAK!!!!
by hvacjamie- Replies
- 42
- Views
- 2,423
walk-in freezer? what method of defrost? if it's...
walk-in freezer? what method of defrost? if it's hot gas, that may be your answer.
-
07-25-2011, 07:42 PM
- Replies
- 4
- Views
- 1,441
yea I recently dealt with this type of issue...
yea I recently dealt with this type of issue where I was focusing too much on the cooling setpoint, and the humidity setpoint was dragging the temp down too much and enabling heat. I would do...
-
$1.00 dawn dish soap bottle and pump sprayer as...
$1.00 dawn dish soap bottle and pump sprayer as previously suggested. you will find it.
-
07-23-2011, 07:40 PM
- Replies
- 11
- Views
- 3,535
what is your incoming voltage?
what is your incoming voltage?
-
07-23-2011, 07:36 PM
- Replies
- 19
- Views
- 3,123
sometimes, if both fans are running, and only one...
sometimes, if both fans are running, and only one has power, it will pull the other and make it appear as though it is going backwards. other than that, your problem will be in the wiring. study the...
-
07-23-2011, 05:05 PM
- Replies
- 19
- Views
- 3,123
the fan may not have the right power at all, and...
the fan may not have the right power at all, and may only be giving the illusion of running backwards. think about this, and see how you could prove that this statement does not apply.
-
05-03-2010, 09:13 PM
- Replies
- 30
- Views
- 3,202
every Mcdonald's location in the world is...
every Mcdonald's location in the world is mandated to perform certifications on the clamshell grills each year. If you can get certified by Garland, the potential for work is huge. Of course, usually...
-
04-28-2010, 07:47 PM
Thread: Coil Cleaner
by hvacjamie- Replies
- 22
- Views
- 2,112
I usually gauge how good the coil cleaner is by...
I usually gauge how good the coil cleaner is by how much the mist is stinging my face. I guess those days are fading. oh well.
Results 1 to 25 of 177