Search:

Type: Posts; User: lowridemazb2200

Search: Search took 0.00 seconds; generated 59 minute(s) ago.

  1. Replies
    58
    Views
    4,144

    yeah i ran into the same problem a couple of...

    yeah i ran into the same problem a couple of months ago with the dryer vent coming loose. I was fixing a drain line between floors and seen that the dryer was disconnected.
  2. Replies
    58
    Views
    4,144

    I'm not mad he is asking the same question I was...

    I'm not mad he is asking the same question I was asking. Im not a DIY person. Im a tech waiting for them to approve my pro membership. I thougt this was a site for tech's to help out other techs,...
  3. Replies
    58
    Views
    4,144

    this sounds like a DIY Post to me. Beenthere you...

    this sounds like a DIY Post to me. Beenthere you need to close this thread.
  4. Replies
    5
    Views
    819

    all the techs on here nobody knows how the...

    all the techs on here nobody knows how the dampers wire up? Does each damper need it's own wire or can they be jumped from one damper to the next? I know all of these experts on here should know...
  5. Replies
    5
    Views
    819

    10-4. It says 30 posts so I'll go and try again

    10-4. It says 30 posts so I'll go and try again
  6. Replies
    17
    Views
    1,205

    I would buy one from a contractor that has been...

    I would buy one from a contractor that has been in business for awhile and has good reviews. All the equipment is the same, Goodman has a better warranty than York. York has problems with their...
  7. Replies
    5
    Views
    819

    Honeywell Multiple Zone damper

    Yes, I'm trying to become a pro member but I dont have enough posts yet. I have been in the HVAC field for only 5 years so I pretty new with this field. I'm working on a house that we are...
  8. Replies
    3
    Views
    393

    Refrigerant Pressure Problems

    Yes I have been doing heating and air work for only 4 yrs. I'm having some problems on a Lennox 13 seer straight air unit. Not even a year old. It has a piston and linesets are probably 30 ft long. ...
  9. Replies
    32
    Views
    1,880

    I'm going to call a different hvac company to do...

    I'm going to call a different hvac company to do a load calc on my house. My furnace does not run that long at all. Also, just to get a second opinion. You guys are making me have second guesses. ...
  10. Replies
    32
    Views
    1,880

    i just wanted to make sure that I was not going...

    i just wanted to make sure that I was not going to get an oversized furnace. The square footage is about 2000 square feet. The house was built in 1992. No additional insulation just what was...
  11. Replies
    32
    Views
    1,880

    you are talking about a 95% furnace right?

    you are talking about a 95% furnace right?
  12. Replies
    32
    Views
    1,880

    North Carolina Far as how long it has ran, it...

    North Carolina

    Far as how long it has ran, it does not run that long but it does not cycle no more then 4 times an hour.

    Can the orifices be changed on the furnace to lower the btu's? I need...
  13. Replies
    32
    Views
    1,880

    They are just going to connect it back up to the...

    They are just going to connect it back up to the original duct work using transitions. So do I go with the 90,000 btu furnace?
  14. Replies
    32
    Views
    1,880

    The company gave me a load calc and they said I...

    The company gave me a load calc and they said I needed 80,000 btu's.

    They want to put in a 95% goodman 90,000btu. I was just wondering if they was choosing the right size furnace. Just want to...
  15. Replies
    32
    Views
    1,880

    So, I dont know if I need to go to 90,000 or drop...

    So, I dont know if I need to go to 90,000 or drop down to 70,000. Any info will be great.
  16. Replies
    32
    Views
    1,880

    Yeah I need 80,000 btu's to heat my house. There...

    Yeah I need 80,000 btu's to heat my house. There is not a furnace that is in the size. I only see the 90,000 and 70,000 one's.
  17. Replies
    32
    Views
    1,880

    ok

    ok
  18. Replies
    32
    Views
    1,880

    A hvac company wants to put in a 90,000 btu 95%...

    A hvac company wants to put in a 90,000 btu 95% goodman furnace in place of the one that I have. The input that is on the old furnace is 100,000 btu. So, if they use this new furnace it well put...
  19. Replies
    32
    Views
    1,880

    NO it sure does not!!

    NO it sure does not!!
  20. Replies
    32
    Views
    1,880

    Gas Furnace

    What was the efficiency of gas furnaces about 16 years ago. What was the most efficient one and the least efficient? Just curious trying to find out what kind is in my house. I have a metal flue...
  21. Replies
    3
    Views
    742

    Coil Size?

    Yes can anyone please tell me what size coil this is? It is an ADP coil.

    Model #: HA05248C210B252284

    Also, my furnace has an input rating of 100,000 btu's I was wondering how many btu's on a...
  22. Replies
    24
    Views
    1,595

    the guys who done the trim on it were not...

    the guys who done the trim on it were not communicating well with each other. (that is a little obvious though) When I first got there they did not even use the same colors. So, I had to rework all...
  23. Replies
    24
    Views
    1,595

    You are right I have those exact ones in the odu.

    You are right I have those exact ones in the odu.
  24. Replies
    24
    Views
    1,595

    I will tell my supervisor to get me a 2 cool 1...

    I will tell my supervisor to get me a 2 cool 1 heat thermostat with dehumidification control. Then the customer will be getting what they sold him.
  25. Replies
    24
    Views
    1,595

    Yeah this is what the supervisor gave me was a...

    Yeah this is what the supervisor gave me was a one heat one cool thermostat on a 2 stage ac unit. I thought that was messed up. Why have the customer pay for a nice unit and not give them all the...
  26. Replies
    24
    Views
    1,595

    Has anyone used one of these units before? I'm...

    Has anyone used one of these units before? I'm using a honeywell vision pro 8000 with one heat and one cool.

    I do this for a living but have only been in the field for 4 years. I think I'm doing...
  27. Replies
    24
    Views
    1,595

    16 Seer Lennox unit

    I'm trying to get this 16 seer 2 stage condenser unit to run. This is in a brand new house trying to complete the start up. It has 3 wires coming out of the condenser instead of two. So it is a 2...
  28. Replies
    26
    Views
    2,464

    How are you checking for the grounded compressor?...

    How are you checking for the grounded compressor? You need to put your meter from one prong on the compressor to a clean piece of copper. If you read something then the compressor is grounded.
  29. Replies
    26
    Views
    2,464

    If your breaker is tripping as soon as you reset...

    If your breaker is tripping as soon as you reset it the compressor is more then likely grounded. If it was locked up it would not trip the breaker right away. To make sure that it is a grounded...
  30. Replies
    12
    Views
    894

    I live in North Carolina, my house is a 2235...

    I live in North Carolina, my house is a 2235 square feet. I have a 2.5 ton ac unit in my house. Mine does great. It is a track house so everything far as the insulation in house is at bear minimum.
  31. Replies
    3
    Views
    506

    Furnace size?

    Yeah I would like to replace my furnace. The gas input on the old furnace is 80,000 btu. It is a 80% furnace. Now, I was wondering if I could get a 95% two stage furnace with 70,000 btus? Will it...
Results 1 to 31 of 31