  1. The Ford Transit T250-T350s are made in the...

    The Ford Transit T250-T350s are made in the USA!!! I have the Transit Wagon (family hauler 15 passenger) with the V-6 Eco Boost. Man that thing is FAST. The build quality seems to be much better...
  2. Replies
    20
    Views
    1,406

    Clean copper brazes SOOOOO much better. Clean em...

    Clean copper brazes SOOOOO much better. Clean em all! Then purge while brazing. I use CO2 and it works fine for keeping flakes of oxide and scale from building up. :)
  3. Replies
    35
    Views
    4,339

    Oh and take a look at this if you think you can...

    Oh and take a look at this if you think you can get back at them for crappy service!

    "I would never buy from this outfit. Direct from their T's and C's:

    There is a minimum fee of $119 when a...
  4. Replies
    35
    Views
    4,339

    Just a warning to all of you, I ordered the...

    Just a warning to all of you, I ordered the Knipex Wrenches from Chadstoolbox.com. BIG mistake! They have no customer service, the order does not go out for at least 3 days and if you don't get your...
  5. Replies
    28
    Views
    5,307

    Tru tech-tools are awesome! Just a warning...

    Tru tech-tools are awesome!

    Just a warning to all of you, I ordered the Knipex Wrenches from Chadstoolbox.com. BIG mistake! They have no customer service, the order does not go out for at least...
  6. Replies
    6
    Views
    561

    Well the one I worked on was high voltage.

    Well the one I worked on was high voltage.
  7. Replies
    6
    Views
    561

    No, it is on the high voltage side, ohm it out,...

    No, it is on the high voltage side, ohm it out, if in doubt, replace, they get flaky. If it electric heat only, and the customer feels cold, bypass it.
  8. Replies
    6
    Views
    561

    The watt restrictor I just saw was the same as a...

    The watt restrictor I just saw was the same as a limit, High Voltage. To the best of my knowledge they are a snap disc limit, so ohm it out.
  9. Replies
    3
    Views
    297

    Hey! From down in New Braunfels! Keep reading,...

    Hey! From down in New Braunfels! Keep reading, you can learn a lot. :)
  10. Thread: flue pipe??

    by KCJN832
    Replies
    19
    Views
    3,114

    Good, neat, work. Only hope the evap. coil is not...

    Good, neat, work. Only hope the evap. coil is not anything Lennox has touched. Their evap. coils are crap. IMHO
  11. Replies
    202
    Views
    9,025

    There is no bible verse that can change your...

    There is no bible verse that can change your mind. I'm ok with that. I only wanted to tell you guys what was on my heart, what you do with it is up to you.
  12. Replies
    10
    Views
    3,123

    Noalox, Ox-guard ect.

    Noalox, Ox-guard ect.
  13. Replies
    4
    Views
    1,355

    You have to register at goodmanmfg.com to get the...

    You have to register at goodmanmfg.com to get the "full factory warranty" and your warranty will get kicked out when it is found that you purchased online. Don't be a cheapskate. Just hire a...
  14. Replies
    202
    Views
    9,025

    I think what GA is getting at is this. Example:...

    I think what GA is getting at is this. Example: GA knows that a cond. unit you are about to touch has shorted to the chassis and the power is still on. He cares because his belief and (I will go out...
  15. Look in the return air vent if there is one under...

    Look in the return air vent if there is one under your unit, and call a good tech.
  16. Replies
    84
    Views
    6,415

    Me too, but the problem here in Texas is calcium...

    Me too, but the problem here in Texas is calcium oxide, so I need a Vac. Outside, Slugs of Water inside, chased by shots of CO2! Some times have to revers the whole process.
    My vac. rig is a dewalt...
  17. Replies
    9
    Views
    742

    Echo-chamber they are!

    Echo-chamber they are!
  18. Replies
    9
    Views
    978

    I know a company that uses Naptha as line set...

    I know a company that uses Naptha as line set cleaner. But not the cheapy Varnish Makers and Painters (low grade)
  19. Don't go into a job looking for how much $$ you...

    Don't go into a job looking for how much $$ you can make. Do it because you love it. :.02:
  20. A real gold digging tool.

    A real gold digging tool.
  21. Replies
    84
    Views
    6,415

    I lost a front tooth using CO2 to clean a drain...

    I lost a front tooth using CO2 to clean a drain line, it had a breather tube after the P trap and I had to hold the drain dawg and hose with one hand and had capped the breather tube with the PVC...
  22. Replies
    84
    Views
    6,415

    Yes Jared looks like you are squared away, just...

    Yes Jared looks like you are squared away, just do your self a big favor and get a VN-500 regulator and a Nitro to CO2 adapter, a clean refer hose and a CO2 tank and you will be all set. (I do...
  23. Replies
    84
    Views
    6,415

    The smaller jugs are rated the same, I just turn...

    The smaller jugs are rated the same, I just turn the 20lb upside down (if it doesn't have a dip tube) use the female to female adapter and extension and open both valves wide open. I don't worry...
  24. Replies
    84
    Views
    6,415

    Yay, We are wining the battle, converting more...

    Yay, We are wining the battle, converting more peeps. I have been in the trade for 21 years and the company i started/stayed with for 19 yrs. only used CO2. No burnouts, no crapped out txv's or...
  25. Replies
    84
    Views
    6,415

    I must not have been privy to the aforementioned...

    I must not have been privy to the aforementioned clover snake outbreak. Do share links, please.
  26. Replies
    84
    Views
    6,415

    You are the first I have heard of, using electric...

    You are the first I have heard of, using electric arc to "braze" copper tubing together.
  27. Replies
    84
    Views
    6,415

    CO2 IS Better

    447521447541447551447561447571Ok, guys. Since the weather is really nice in Texas right now, I went out to the workshop and did a CO2 Braze Job with my new CO2 Reg. VN-500...
  28. Replies
    28
    Views
    4,586

    You aren't the only one

    During inclement cold weather here in South Texas we have a number of those type of problems
  29. Replies
    3
    Views
    1,202

    Thanks, good idea. :)

    Thanks, good idea. :)
  30. Replies
    28
    Views
    4,586

    I had the same problem 2 weeks ago with Lennox...

    I had the same problem 2 weeks ago with Lennox and Goodman HP CU's, I set the defrost termination to 90 deg. and got the homeowners to pour hot water on the blades and shroud. It was freakish weather...
  31. Replies
    5
    Views
    754

    Well any tech worth his salt should be able to...

    Well any tech worth his salt should be able to isolate the problem/miss wire/or faulty board/t-stat.
    Look up a tech I your area on Hvac-talk

    Cheers,
    And yes the quick fix is turning off the...
  32. Replies
    3
    Views
    1,202

    Gas Closet to Attic Heat Pump conversion

    Took me 2.5 days, but they now have 300% better airflow, a big closet, and a safe heater, (old furnace would roll out and CO)
    Sent from my HTC One using Tapatalk 2
  33. Replies
    8
    Views
    890

    Goodman CTK-03 is what you want. The previous...

    Goodman CTK-03 is what you want.
    The previous pic posted was the CTK01, avoid the CTK02.
  34. Replies
    33
    Views
    4,743

    [QUOTE=John8385;16289711] I thought goodman...

    I thought goodman was crap as well, but then I started into the 06-12 Lennox Evap. Coils OH MY!!!!
    I don't even need a leak detector, I look for oil on the steel plates, then if it is mixed with a...
  35. I would start looking at the cond. fan motor,...

    I would start looking at the cond. fan motor, those emerson motors can run but not give enough air flow to cool the compressor and it will go off on a high temp overload. Have your tech check the...
  36. Replies
    18
    Views
    1,681

    Angle iron

    We always made our own L brackets with an angle connector making the bracket a tri-angle. In your case the L will be facing the ground. Pre drill the 1/4" 2x2 angle iron with a drill press for the...
  37. SQ Ft. Rule

    On average here in Texas, I'm using 670sq ft. per ton! But you have to remember that I strictly use heat pumps.
  38. Replies
    6
    Views
    635

    Yeah, I have noticed that it is harder to flow,...

    Yeah, I have noticed that it is harder to flow, but it has made me a better brazer.
  39. Replies
    6
    Views
    635

    To use silver or not?

    Has anyone had experience using this Harris 0 silver Phos for brazing?
  40. As a Company Owner I have tried to find the...

    As a Company Owner I have tried to find the balance of value vs. quality, and I encourage the customer to only go with the companies that have all aluminum evaporators in their heat pumps....
  41. The video show a 4th leg on the motor which I...

    The video show a 4th leg on the motor which I believe is the "shipping" bolt connection. I would get the installer back out there to verify that it was removed properly. Don't do it your self....
  42. Don't even mention disconnecting and redoing the...

    Don't even mention disconnecting and redoing the connection! If they know anything, they will handle it, no sweat. :) pun intended. It will move the unit out from the wall a little to accommodate...
  43. I've heard of one AC company using Naptha as a...

    I've heard of one AC company using Naptha as a solvent to clean the lines, but they had to be very careful to get the pure stuff because many brands have oils in them. I recently heard that they are...
  44. Are you sure it is worth your time and labor to...

    Are you sure it is worth your time and labor to go extreme labor just to change the condenser? I would Strongly suggest you change the cond. unit with a newer used 1.5 ton, that way you will be...
  45. Replies
    8
    Views
    1,418

    Don't be too hard on your self, we all have had...

    Don't be too hard on your self, we all have had our share of butt kicking intermittent shorts. I don't have a diagram, but I have seen the contactor give trouble before, or more likely in the wiring...
  46. Thread: Restriction

    by KCJN832
    Replies
    7
    Views
    1,006

    The Suction Pressure went up about #3-4 and the...

    The Suction Pressure went up about #3-4 and the Liquid went up about #10-20
  47. Thread: Restriction

    by KCJN832
    Replies
    7
    Views
    1,006

    Ok, great help guys, thx! I will certainly check...

    Ok, great help guys, thx! I will certainly check that out if they call me back. (Previous hacker was going to be called back) :(
  48. Thread: Restriction

    by KCJN832
    Replies
    7
    Views
    1,006

    Restriction

    Got a weird one yesterday. 95' trane 1.5ton HP with S#40, SH 45, L#315, SC 60,
    Looked like a major restriction to me, and when i was connecting the suct. gauge got foaming oil both times. Possible...
  49. Replies
    15
    Views
    2,097

    Don't do the job if they won't have a 4-5"...

    Don't do the job if they won't have a 4-5" filter. They would be dropping 3 filters a month with all the RA's and a 4-5" goes 6-12 mo down here in Texas. Cost savings, air flow/ volume, cleanliness...
  50. Replies
    2
    Views
    475

    I have used it a few times to double check my...

    I have used it a few times to double check my rule of thumb in downsizing equip, and satisfy power companies rebate program requirements. It is pretty easy to run a block load calc., wish it could...