Search:

Type: Posts; User: J_Bridge

Search: Search took 0.01 seconds.

  1. Manitowoc has some financing options available on...

    Manitowoc has some financing options available on their web site. The new indiago units have a lot of things you can check and read out to help diagnose in the future after the three year parts and...
  2. Replies
    23
    Views
    6,822

    Guys, he jumpered the float switch. This...

    Guys, he jumpered the float switch. This eliminates any water issues and goes back to a board issue or a connection. I would agree with craig1 and check the board. You have jumped the wire...
  3. Replies
    17
    Views
    1,592

    There is also a drain for the head on the I...

    There is also a drain for the head on the I series, different from the pump out drain. There is a service communicator on it. So the heads have two different drains. The I series are a completely...
  4. Replies
    13
    Views
    1,836

    Post some pics, this would help us all on some...

    Post some pics, this would help us all on some ideas. There are many options that can be applied.
  5. Thread: Kold Draft

    by J_Bridge
    Replies
    7
    Views
    1,571

    There are a lot of the newer style kold drafts...

    There are a lot of the newer style kold drafts and the older ones that we work on. Not a big fan of them, I don't see why an ice machine manufacturer can't get their charge properly. The...
  6. Replies
    30
    Views
    3,795

    I have been doing this for over 13 years and my...

    I have been doing this for over 13 years and my company for over 35 years and we have never had a tstat in the coil on a WIC. But let me clarify what I am calling off cycle defrost. We always...
  7. Replies
    30
    Views
    3,795

    Stick a tstat of a walk in cooler in the coil?...

    Stick a tstat of a walk in cooler in the coil? What? You should never do that! Return air is where the bulb should be at, t-stat set to cut out at 32 degres in ice water(calibrate). The numbers...
  8. Replies
    9
    Views
    1,636

    Isn't this showing 4 defrost a day at 40 minutes...

    Isn't this showing 4 defrost a day at 40 minutes long? one at 6:45, 12:45, 6:45 and 12:00? Yeah that is a problem, 4th defrost needs to changed to 24:45 to be inlign with the others that are all 6...
  9. Replies
    7
    Views
    1,397

    Go TXV, it will repond better and you can know...

    Go TXV, it will repond better and you can know with a full sight glass you are properly charged. Plus you will get more precise adjustment from the valve. pump unit down, install txv, change drier,...
  10. Replies
    28
    Views
    4,024

    Just on the outlet from what was understanding...

    Just on the outlet from what was understanding from sporlan
  11. Replies
    6
    Views
    1,149

    Ok here it is. 20 degree superheat at the...

    Ok here it is. 20 degree superheat at the compressor during a load situation and no lowere. This ensures that at night under low load we still have superheat at the compressor and not a saturation...
  12. Replies
    28
    Views
    4,024

    Sporlan C052capt-tt-hh drier is specificall...

    Sporlan C052capt-tt-hh drier is specificall designed for cap tube systems with wax issues. It has carbon, solid core, strainer and felt pad. Sporlan made it for these specific issues.

    And...
  13. Replies
    10
    Views
    1,488

    I agree, if you have a compressor or evaporator...

    I agree, if you have a compressor or evaporator on a unit that is out of warranty. Highly recommend replacement, if they do repair I quote everything, txv's, head master,
    hot gas valves. You...
  14. Replies
    34
    Views
    4,755

    Oh yeah I didn't state this yet. My company I...

    Oh yeah I didn't state this yet. My company I work for is Authorized with every mfg. for commercial refrigeration, so we do a lot of warranty work. We have had in place for 5 years now a contract...
  15. Replies
    17
    Views
    2,656

    I know the customer doesn't like to remove the...

    I know the customer doesn't like to remove the ice, but to do the job right and prevent future failures this is what we require. If not it is noted and that way we aren't responsible or liable. Now...
  16. Thread: Kold Draft

    by J_Bridge
    Replies
    7
    Views
    1,571

    Kold Draft

    Has anybody else had the pleasure of working on these new style Kold Drafts that have had a surge on the market? If so how do you feel about all there issues? I wish they would figure out how to...
  17. Replies
    43
    Views
    6,253

    Thats the ones I have seen and used, thanks for...

    Thats the ones I have seen and used, thanks for the link. These are perfect, I have seem some mylar style as well. But this site looks great!
  18. Replies
    43
    Views
    6,253

    sorry for my typos, was using a smart phone and...

    sorry for my typos, was using a smart phone and it was late.
  19. Replies
    34
    Views
    4,755

    Scotsman definately has a long hold time,...

    Scotsman definately has a long hold time, Manitowoc has after hours help to on warranty calls. you just have to wait a long time. but so do the other 4 companies. And I haven't had to wait to long...
  20. Should have posted this in the ice machine forum,...

    Should have posted this in the ice machine forum, what are you trying to calibrate? I have worked on several of them, new and old. The gentlman at the factory is very knowledgable. I printed a...
  21. Replies
    34
    Views
    4,755

    Never had issues out of Manitowoc either, we are...

    Never had issues out of Manitowoc either, we are a csr and our regional service manager is great. You have to communicate with them, especially your regional service manager about special...
  22. Replies
    6
    Views
    1,149

    I will find out. I know this is to ensure all...

    I will find out. I know this is to ensure all the refrigerant is boiled off, but will get more details.
  23. Replies
    28
    Views
    4,024

    Last I checked sporland doesn't use a pad. I...

    Last I checked sporland doesn't use a pad. I have never had an issue with that, I will check with my rep tomorrow on that though.
  24. Replies
    6
    Views
    1,149

    Welling service is correct, box needs to close to...

    Welling service is correct, box needs to close to temp. 8-10 frz and 10-12 on coolers, but make sure that at your comp you are no lower than 25 degrees. That is a coprland spec, you can go 20 but...
  25. Replies
    10
    Views
    1,488

    Why would you ever use a used compressor? I...

    Why would you ever use a used compressor? I work on 7 or cubers a week and woukd never jeporadize my customer by installing used parts, not worth the hassel of unloading my van, recovering...
  26. Replies
    28
    Views
    4,024

    I don't care, True mfg also sends out bullet...

    I don't care, True mfg also sends out bullet driers. If you stop using a drier that sounds like it has sand in it you will nevet have an issue. My company always uses solid core driers, even if we...
  27. Replies
    43
    Views
    6,253

    I don't know whay brand your cas is. Look...

    I don't know whay brand your cas is. Look online, i have seen them on structural concepts cases and many other brands. I will look as well to see what i can find. The usually call the "night...
  28. Replies
    15
    Views
    2,248

    Cody is correct, you can hammer them back in and...

    Cody is correct, you can hammer them back in and put an x on the cross poins of the grid. This burs the metal to hold the grids in place. The cost of a new plate only justifies a new unit. But...
  29. On the indigo, use a 9/32 drill to set the...

    On the indigo, use a 9/32 drill to set the thickness. That is all it needs to obtain a 1/8 bridge, There is also new books with the diagnostic info in them, last years books are trash. The new books...
  30. Replies
    17
    Views
    2,656

    Where I work we ask the customer to remove and...

    Where I work we ask the customer to remove and store the ice. This allows cleaning and sanitizing of the bin. In the instance they forget and we show up, I usually use trash bags to cover the ice...
  31. 336301

    336301
  32. Replies
    28
    Views
    4,024

    I am not trying to push one brand over another...

    I am not trying to push one brand over another but you need to install a co52capt drier, its sporlan. Solid core with access ports, you can check your pressures. Those bullet driers aren't even...
  33. Replies
    43
    Views
    6,253

    Ok, Number one issue with open air case is that...

    Ok, Number one issue with open air case is that enviroment around it. That door that swings open around it is a problem, no vents, doors or even product not being put in correctly will cause issues....
  34. Don't worry about the heat if you are using an...

    Don't worry about the heat if you are using an oxy/acet rig. get in with the heat and get out. I wouldn't worry about a purge gas either, doesn't hurt but I wouldn't worry about it. Use a wet rag...
  35. Get box to temp with txv at mid point, set...

    Get box to temp with txv at mid point, set superheat to 10-12 degrees and ensure not below 25 degrees at compressor. Also a side note, we always add a timeclock and pump system down. 4 x 30 min,...
  36. Replies
    2
    Views
    1,351

    Call scotsman, this sounds like it is in a...

    Call scotsman, this sounds like it is in a programming mode.
  37. Replies
    8
    Views
    1,179

    The hobart R/I/F had a heater safety to drop out...

    The hobart R/I/F had a heater safety to drop out the heaters. The OEM mounts on the coil and one leg to heater and the other out of the clock. Set for a 20 min. defrost originally. The R/I...
  38. Thread: True Doors

    by J_Bridge
    Replies
    7
    Views
    738

    True also offers a kit for caster units and...

    True also offers a kit for caster units and possible leg units. It has new front to back braces that you have to bolt up and the casters are welded on. Had a 3 section freezer that had a door...
  39. Replies
    12
    Views
    2,058

    ....And don't use one of the spun/bullet driers, ...

    ....And don't use one of the spun/bullet driers, solid core ones are better and help to catch some of the trash.
Results 1 to 39 of 39
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event