Search:

Type: Posts; User: EliTheIceman

Search: Search took 0.01 seconds.

  1. Replies
    6
    Views
    745

    Leak test?

    How do you leak test during an install/repair? The guys I work with call it good if they pull a vacuum down past 500. I just had this fail for me so now I've been valving off the pump and making sure...
  2. Replies
    13
    Views
    1,003

    Yeah, I'm going to try this when the time is...

    Yeah, I'm going to try this when the time is right. I've seen demonstrations of brazing w/ and w/o nitrogen and the results are honestly amazing. Maybe I 'll demonstrate this to them also and give...
  3. Replies
    32
    Views
    2,382

    Yes, they use digital multi-meters. I don't know...

    Yes, they use digital multi-meters. I don't know anyone that still uses a voltmeter and an ammeter and an ohmmeter, etc. It's just outdated, I know. Look, my point was just to imply that analog...
  4. Replies
    32
    Views
    2,382

    I most definitely am being influenced by the "old...

    I most definitely am being influenced by the "old timers" that I work with because I spend 40+ hours a week w/ them. And No, I have NEVER seen any proof that the Testo 510 is off in any way. The...
  5. Replies
    61
    Views
    4,582

    Haven't been in the field for very long (I...

    Haven't been in the field for very long (I admit), but I already realize the EXTREME communication gap between engineers and those of us who work in the field. On another note it seems that Lennox...
  6. Replies
    32
    Views
    2,382

    I asked this question awhile back and got heavily...

    I asked this question awhile back and got heavily referred to the Testo 510. So I bought it and I like it for the small and simple to use aspect of it. Then my company ordered me the Dwyer U-tube...
  7. Replies
    13
    Views
    1,003

    My company uses micron guages. However, we do not...

    My company uses micron guages. However, we do not purge with nitrogen. I'm 9 months out of trade school and was taught to purge with nitrogen, but my company does not practice this, so now I don't...
  8. Thread: Magjumper

    by EliTheIceman
    Replies
    10
    Views
    2,862

    Mag jumper

    I've got 2 of these so I can test hi & lo fire w/o waiting 10 min. (or whatever the delay may be), on gas furnaces. Have ran into trouble with some screws actually having been de-magnetized, so...
  9. Replies
    14
    Views
    1,463

    M12

    I have the Milwuakee M12 impact & love it. I saw a youtube video where a guy did a pretty good comparison between the M12 and Bosch's impact http://www.youtube.com/watch?v=dx6ttcAFVM4. Hope I helped.
  10. Replies
    16
    Views
    2,093

    Some areas (including mine) require purple primer...

    Some areas (including mine) require purple primer per code. I agree w/ the visual aspect, but gotta follow the rules no matter how ridiculous.
  11. Replies
    52
    Views
    11,444

    $

    I'm in Iowa (small rural community). Completed a trade school in May & started out @ $12/hr. Busted my ass and in July was @ $13/hr. Then, took an apprecticeship placement exam and got put in the 3rd...
  12. Replies
    6
    Views
    884

    static pressure tips

    Just ordered the Testo 510 manometer. What static pressure tips do you have/suggest? Also, what lengths are they?
  13. Replies
    22
    Views
    1,073

    School

    I got out of trade school back in May and have been working for an HVAC/R, electrical, plumbing contractor ever since. I would say 1) Understand the basic mechanical refrigeration system and it's...
  14. Replies
    41
    Views
    4,403

    I was told to spray water with a simple garden...

    I was told to spray water with a simple garden sprayer up the fire-box, with the blower pulled, and then look into the heat exchanger for signs of water running down in it. I've praciticed this...
  15. Replies
    17
    Views
    2,441

    Static pressure testing tool of choice

    What tool do you use to test SP? I've yet to buy a tool for this (I'm an apprentice) and my co-workers all have a Dwyer oil manometer that can be mounted horizontal for SP readings. They laughed @ me...
  16. Thanks

    Thanks to those who replied. ACCA Manuals D & T are now on my priority "get list".
  17. Most important things to know about ducts

    1st time post, long time browser. I am an apprentice for a company that does it all (hvac, refrigeration, electrical, appliances, plumbing, geo-thermal) and have been looking for a place in the...
Results 1 to 17 of 17