Search:

Type: Posts; User: lynden

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    5
    Views
    329

    I believe that you can select if you want to use...

    I believe that you can select if you want to use the furnace during defrost in the advanced settings of the UI. I would not think that the furnace running during defrost would cause your indoor coil...
  2. Replies
    2
    Views
    311

    You will learn something every time you come...

    You will learn something every time you come here, welcome.
  3. Replies
    21
    Views
    1,478

    Maybe I should go back on the one I had and look...

    Maybe I should go back on the one I had and look for a hamster!
  4. Replies
    21
    Views
    1,478

    I had a piece of aluminum foil land on top of the...

    I had a piece of aluminum foil land on top of the primary limit after falling off the underside of the evaporator coil, causing a short to the heat exchanger. I still have no idea where the foil came...
  5. Thread: Tinner

    by lynden
    Replies
    10
    Views
    860

    We make everything ourselves, or I should say,...

    We make everything ourselves, or I should say, they make everything ( our tinners). The only thing I've perfected when it comes to sheet metal, is bleeding.
  6. Replies
    15
    Views
    1,459

    Won't the jumper from aux to G bring the heat on...

    Won't the jumper from aux to G bring the heat on with a cooling call also??
  7. Thread: Hiel H9mpd075

    by lynden
    Replies
    18
    Views
    1,445

    Could the manifold be cocked, or twisted, not...

    Could the manifold be cocked, or twisted, not allowing the orifices to point straight into the burners? Just a thought, let us know what you find!
  8. Thread: dog food

    by lynden
    Replies
    30
    Views
    4,076

    Nutro, natural choice. Our lab has ate it since...

    Nutro, natural choice. Our lab has ate it since she was a pup, will be 14 in July. It's about 40 bucks for 30# here. She goes though 1 bag every weeks.
  9. Yeah, they don't give up as long as they get...

    Yeah, they don't give up as long as they get alittle attention every now and then.
  10. George, was the other name chippawah? We...

    George, was the other name chippawah? We installed truck loads of the aprilaire 224, that's all our company put in, along with all those orange door Chryslers!! That was a few years ago though,...
  11. Replies
    14
    Views
    3,887

    Ahhh.....well...... Yeah? No, I didn't pay...

    Ahhh.....well...... Yeah? No, I didn't pay attention to dates, sorry. Still, nice job!
  12. Replies
    283
    Views
    30,019

    It's probably too late for us, after all the bad...

    It's probably too late for us, after all the bad habits we've picked up over the years
  13. Replies
    14
    Views
    3,887

    Very clean, sure makes trouble shooting easier...

    Very clean, sure makes trouble shooting easier down the road. Nice work, I like the labels as well.
  14. Replies
    283
    Views
    30,019

    With his electrical back ground, of course...

    With his electrical back ground, of course they're safe.
  15. Replies
    283
    Views
    30,019

    I hope for his sake when he has that humbling...

    I hope for his sake when he has that humbling experience it is not at the expense of someone's well being.
  16. Replies
    9
    Views
    1,485

    I have never seen it done before, but have found...

    I have never seen it done before, but have found quite a few evap. Coils sitting on top of counterflows over the years. Destroys a heat exchanger pretty quickly.
  17. Replies
    27
    Views
    5,999

    Very nice work!! As a service tech, I appreciate...

    Very nice work!! As a service tech, I appreciate seeing all the manuals left where they will do the next guy some good. We started installing a metal file box for all paperwork on the drop of our...
  18. Thread: Broke my finger

    by lynden
    Replies
    35
    Views
    3,862

    Looks like your doc does good work, sucks that...

    Looks like your doc does good work, sucks that its your driving finger!
  19. Thread: Broke my finger

    by lynden
    Replies
    35
    Views
    3,862

    I fell and torn it originally, but think I...

    I fell and torn it originally, but think I finished it off picking up our 16 month old son.
  20. Replies
    15
    Views
    2,079

    I would check for s spider nest in the manifold....

    I would check for s spider nest in the manifold. It sounds like that burner is starving for some reason.
  21. Replies
    19
    Views
    3,494

    DeltaT, Depending on your model #, most...

    DeltaT,
    Depending on your model #, most Lennox units have the capability of selecting what type of thermostat Is being used (single, or multi-stage) in your dip switch settings. If single stage...
  22. Thread: Broke my finger

    by lynden
    Replies
    35
    Views
    3,862

    I wish you a speedy recovery! I too am in the...

    I wish you a speedy recovery! I too am in the same boat, had rotator cuff surgery Friday. I have been assigned the couch for the next 8 weeks!
  23. Replies
    5
    Views
    1,006

    I'm not sure if there is a difference between...

    I'm not sure if there is a difference between infinity and evolution( Bryant's version), but they did have a problem with the UI loosing its memory. I believe it was on the version 16 and older. If...
  24. Replies
    13
    Views
    2,310

    I have seen this happen with w/r thermostats when...

    I have seen this happen with w/r thermostats when the batteries go dead. I also had a humidistat bringing on the heat due to being miswired. Maybe something to check, good luck!
  25. Replies
    14
    Views
    2,312

    Is this unit on LP? I think carrier had an add-on...

    Is this unit on LP? I think carrier had an add-on lock out timer, and gas pressure switch that tied into in incoming pressure tap of gas valve. I have changed many lock out timers for this problem...
  26. Thread: Apps

    by lynden
    Replies
    4
    Views
    856

    Thanks for the replies!

    Thanks for the replies!
  27. Replies
    11
    Views
    1,069

    I'm not sure, but I think this is a Chrysler ...

    I'm not sure, but I think this is a Chrysler air temp. I think it is a model 1260?
  28. I would tell him thank you, and i finally get...

    I would tell him thank you, and i finally get it!! My dad died about a month before our first child was born, always used to tell me "just wait until you have one of your own, then you'll get it". I...
  29. Replies
    12
    Views
    1,125

    I think carrier has always been .58oz per foot, I...

    I think carrier has always been .58oz per foot, I think Lennox says 3oz for every 5 additional feet. this is on 3/8 liquid line
  30. Replies
    6
    Views
    1,474

    I screw a Schradder tee on, then you fix the...

    I screw a Schradder tee on, then you fix the leak, and still have an access
  31. Thread: Apps

    by lynden
    Replies
    4
    Views
    856

    Apps

    Hello to all. Finally got an I phone, can anyone suggest some good apps for our trade. I work for a primarily residential company, with some lite comm. thanks!
  32. Replies
    25
    Views
    2,533

    I would guess only the bottom of the coil froze...

    I would guess only the bottom of the coil froze from not being fed evenly, but just a guess. Let me know what your Tech support guy has to say.
  33. Replies
    25
    Views
    2,533

    I will also take a wild guess, maybe you have a...

    I will also take a wild guess, maybe you have a floating restriction and when you shift system into heat mode to thaw coil ,it is flushed back out into the system again. Is the drier installed at the...
  34. Thread: ICP 4 Way Valve

    by lynden
    Replies
    6
    Views
    1,052

    I have used large bolt cutters before ,If you...

    I have used large bolt cutters before ,If you have the room, and cut all four lines at the body of the rv. Then, you can unsweat the stubs individually. Since yours is under warranty though, may not...
  35. When in the cooling mode, the reversing valve is...

    When in the cooling mode, the reversing valve is suppose to direct discharge to the outdoor coil
  36. I would tend to agree with dr. Phil, sounds like...

    I would tend to agree with dr. Phil, sounds like a indoor txv problem. I would think if the reversing valve wasn't shifting completely in the cooling mode you would have a higher suction pressure if...
  37. Replies
    65
    Views
    5,367

    Yes i know, just thought it was silly of me to...

    Yes i know, just thought it was silly of me to comment on posts made so long ago as far as determining which side is which
  38. Replies
    65
    Views
    5,367

    My bad!!!! Still getting used to this site,...

    My bad!!!! Still getting used to this site, didn't realize this thread was a year old. I'm sure everyone with a veto has figured out a good marking system. I still love the bag though!
  39. Replies
    65
    Views
    5,367

    I bought an LC about 4 months ago. I agree at...

    I bought an LC about 4 months ago. I agree at first, damn it was heavy, but the shoulder strap, and how it rides on your shoulder, makes it very comfortable. I too had trouble remembering what side...
  40. Replies
    37
    Views
    2,598

    Poll: I have worked for a lennox dealer for going on 20...

    I have worked for a lennox dealer for going on 20 years. I have to say that lennox has definately had their ups and downs, but they seem to always get the bugs worked out. That said, i would rather...
  41. Replies
    28
    Views
    2,029

    Just a thought, could you replace reversing valve...

    Just a thought, could you replace reversing valve coil with a 230 volt coil, and power it off the line side of contactor?
  42. Replies
    6
    Views
    2,616

    If installing the original board and wiring the...

    If installing the original board and wiring the blower hot gained u heat, then that is telling me the voltage, ignitor, ignitor circuit and ground are ok. Sure makes me wonder what is causing this...
  43. Replies
    6
    Views
    2,616

    Chris, I have seen the same error code many times...

    Chris, I have seen the same error code many times before. The 63k89 was really bad about it. I did the same thing you have, checked voltage, polarity, ignitor, and ground...all ok. If it is not the...
  44. Replies
    52
    Views
    4,240

    Medic, good point. that would make you an honest...

    Medic, good point. that would make you an honest tech that the customer is going to call again. Our company has given several second oppinions and gained many customers by fixing equipment that...
  45. Replies
    7
    Views
    791

    "Hey chicago whata ya say", Cubs or Sox

    "Hey chicago whata ya say", Cubs or Sox
  46. Replies
    52
    Views
    4,240

    the ability to put yourself in the customers...

    the ability to put yourself in the customers shoes, if it can safely be fixed, then fix it. If the customer wanted new equipment, they would of scheduled an estimate, not a service call
  47. Replies
    49
    Views
    3,892

    I thought lennox were the only one's to use rfc...

    I thought lennox were the only one's to use rfc line , did carrier too?
  48. Replies
    39
    Views
    2,356

    this forum is unbelivable!! It's not enough that...

    this forum is unbelivable!! It's not enough that i have already learned more than i thought i knew about hvac, but now this. My dad had suffered with gout for years and i was blessed with my first...
  49. Sticky: Mikeybow, welcome! New here myself, look forward...

    Mikeybow, welcome! New here myself, look forward to learning from you, and hope somewhere along the line maybe I can return the favor
  50. Thread: Furnace barking

    by lynden
    Replies
    10
    Views
    2,530

    you might verify your incoming gas pressure, had...

    you might verify your incoming gas pressure, had a g71 act the same way, like something in the intake, It would lite ok, but when dropped to low fire the burners would surge. this was due to incoming...