  1. Replies
    12
    Views
    1,761

    I listened to a friends Ruud unit with a scroll...

    I listened to a friends Ruud unit with a scroll and it sounds about like mine so I am going to say its fine
  2. Replies
    12
    Views
    1,761

    is TEch #3 correct?? did his checks ensure a...

    is TEch #3 correct?? did his checks ensure a properly operating/healthy compressor or were there other things he should have done??
  3. Replies
    7
    Views
    1,207

    If its a Copeland Scroll then Copeland makes a...

    If its a Copeland Scroll then Copeland makes a custom blanket for it.
  4. Replies
    12
    Views
    1,761

    Tech number 3 came out this evening and said it...

    Tech number 3 came out this evening and said it was fine. Said it was quieter than his unit!!

    All he did was put an Amp gage on it and then his gauges. Said if it wasnt operating properly he would...
  5. Replies
    12
    Views
    1,761

    2 ton Ruud condenser with Copeland Scroll...

    2 ton Ruud condenser with Copeland Scroll compressor. House is nice and cool and humidity runs between 35-40%. It had no problem keeping the house at 72 when we had a 95 degree day.

    Compressor is...
  6. Replies
    3
    Views
    851

    10 vents on backside of ridge with soffit vents...

    10 vents on backside of ridge with soffit vents in the front and getting ready to add vents to new soffit on rear of house. That may cool the attic a little more
  7. Replies
    3
    Views
    851

    Here in Va today its 91 degrees and 61RH at 2:45...

    Here in Va today its 91 degrees and 61RH at 2:45 in the afternoon. Its right at 100 degrees in my attic where the the airhandler and R6 flex duct is located.

    Temp drop across the coil is return 73...
  8. Replies
    9
    Views
    1,185

    The top of the Scroll Compressor in my Ruud UAKB...

    The top of the Scroll Compressor in my Ruud UAKB 024JAZ condenser is running at 175 as measured by laser thermometer. The rest of the compressor is relatively cool to the touch.

    Is this high temp...
  9. Replies
    29
    Views
    2,954

    System Performance Update

    Here in Chesapeake Va today high 87 degrees. Currently 86 degrees and 63 RH.

    Current

    Thermostat set at 72 and inside RH is 38

    Register temp at closest to airhandler 57 degrees

    Register...
  10. Replies
    6
    Views
    3,073

    Have done a little research. Looks like a lot of...

    Have done a little research. Looks like a lot of the higher end units come with the sound blankets from the factory.
  11. Replies
    10
    Views
    1,734

    Thank you. Just like the orifice is!! Im not...

    Thank you. Just like the orifice is!! Im not sure what I was thinking. Should any competent tech be able to install a txv?? Are there any definately do's and/or anything to make sure he doesnt do...
  12. Replies
    6
    Views
    3,073

    Anybody use them? Do they provide subsatntial...

    Anybody use them? Do they provide subsatntial noise abatement?

    Any reasons not to use??

    Noisy scroll compressor.
  13. Replies
    10
    Views
    1,734

    Im still interested in how they are rated?? Do...

    Im still interested in how they are rated?? Do you buy it for the btu rating of your system or to match your evaporator coil??

    Im not doing this myself but I have learned to be a smart as I can...
  14. Replies
    10
    Views
    1,734

    Im not doing the work myself but am curious and...

    Im not doing the work myself but am curious and may get it done based on the expert opinion here.

    Can a TXV be installed on 10Seer equipment?? Is it coil specific or are TXV's rated by ton??

    2...
  15. Replies
    29
    Views
    2,954

    Todays tech says liquid line 3/8 instead of 1/4...

    Todays tech says liquid line 3/8 instead of 1/4 wouldnt cause compressor noise. Says slight kink in vapor line wouldnt cause compressor noise. Says .002 differnce in orifice size wouldnt cause...
  16. Replies
    6
    Views
    1,048

    Thank you. I appreciate the help.

    Thank you. I appreciate the help.
  17. Replies
    29
    Views
    2,954

    The systems keeping the house comfortable and dry...

    The systems keeping the house comfortable and dry but the Copeland Scroll quietest most vibration free compressor ever is making a heck of a loud Humming that vibrates thru the wall of my bedroom. ...
  18. Replies
    21
    Views
    2,240

    Im in Chesapeake just next door to Va Beach. ...

    Im in Chesapeake just next door to Va Beach.

    I will add that I noticed yesterday after we evacuated, vacuumed to 350microns...while charging I noticed the compressor ran really quiet for a while...
  19. Replies
    29
    Views
    2,954

    Per ARI the coil and condenser combination are...

    Per ARI the coil and condenser combination are rated 10seer. I assume they are therefore fine to use as a system. Apollo air handlers are all matched to somebody elses condenser.....Apollo doesnt...
  20. Replies
    21
    Views
    2,240

    Its been set on 72 all day. Its ran a total of...

    Its been set on 72 all day. Its ran a total of 6.5 hrs since midnight last night.
  21. Replies
    29
    Views
    2,954

    I have better air flow from my vents than I did...

    I have better air flow from my vents than I did before system change??
  22. Replies
    21
    Views
    2,240

    3/4 by 3/8 line set with very slight kink in the...

    3/4 by 3/8 line set with very slight kink in the 3/4 line right where it enters foundation.

    At noon today the register air was about 16 degrees cooler than room temp. This evening the register air...
  23. Replies
    21
    Views
    2,240

    Correct problems and compressor runs fine or is...

    Correct problems and compressor runs fine or is this a condition that destroys the compressor in short order???
  24. Replies
    21
    Views
    2,240

    System is cooling and dehumidifying my house...

    System is cooling and dehumidifying my house great. The scroll compressor is too noisy and the noise is being transmittred into the wall thru the lineset.

    Maybe liquid slugging?? maybe just bad...
  25. Replies
    6
    Views
    1,048

    condenser and air handler same brands and same...

    condenser and air handler same brands and same capacities as old units. ducts replaced with new R6 but all same size.
    72 degree return air into airhandler and 55 degree air from air handler four...
  26. Replies
    6
    Views
    1,048

    air handler in attic sweating a little around the...

    air handler in attic sweating a little around the drain nipples and dripping into drain pan under handler and the first couple feet of condensation line drains are sweating?

    Normal???

    [Edited...
  27. Replies
    8
    Views
    1,617

    I've had a lot of stress trying to determine if...

    I've had a lot of stress trying to determine if my Apollo SA3024 airhandler and RUUD UAKB 024JAZ were compatable and whether or not I needed to change the orifice in the airhandler.

    Supposed...
  28. Replies
    10
    Views
    1,327

    If scroll is starting in reverse and causing...

    If scroll is starting in reverse and causing noisy operation.....

    1. would the system still cool the house normaly as mine does??

    2. how do you make it stop starting in reverse??

    3. does it...
  29. Replies
    10
    Views
    1,327

    Im told by tech that he's seen vapor lines kinked...

    Im told by tech that he's seen vapor lines kinked pretty good without really affecting performance.

    Once again this kink has definately been there for 18 years since the house was new.

    Whats...
  30. Replies
    10
    Views
    1,327

    less than 1/4 the thickness of the line and of...

    less than 1/4 the thickness of the line and of course it caused it to be slightly wider so wouldnt think total flow is affected that much but did change the shape of line at that point.

    at kink...
  31. Replies
    10
    Views
    1,327

    Kink in the large line of the lineset right where...

    Kink in the large line of the lineset right where it comes out of the foundation. Im sure its been there since the lineset was installed 18 years ago.

    What would this kink cause?? With the new...
  32. Thread: Duct Mastic

    by mikeinva
    Replies
    12
    Views
    1,201

    I will be sure to let you know if the piston...

    I will be sure to let you know if the piston changeout, vacuum and recharge results in a quiet compressor. I have been told the copelands can take some abuse so hopefully a couple days running loud...
  33. Thread: Duct Mastic

    by mikeinva
    Replies
    12
    Views
    1,201

    so the oil in the compressor is isolated and...

    so the oil in the compressor is isolated and remains in the system during a vacuum to 500 micron??

    Vacuum doesnt remove any of the oil?
  34. Thread: Duct Mastic

    by mikeinva
    Replies
    12
    Views
    1,201

    Thank you. You have been a great help :) Can...

    Thank you. You have been a great help :)

    Can you help on my question about the Scroll Compressor and whether vacuuming the sytem pulls the oil out of the compressor?
  35. Replies
    5
    Views
    5,788

    My new 2 ton Ruud UAKB 024JAZ condensor copeland...

    My new 2 ton Ruud UAKB 024JAZ condensor copeland scroll compressor is making a loud hum that comes and goes but is there most of the time. My installer and 3rd party tech believe its because we used...
  36. Thread: Duct Mastic

    by mikeinva
    Replies
    12
    Views
    1,201

    Is the mastic messy or does it pretty much stay...

    Is the mastic messy or does it pretty much stay where its put?? Mastic right over tie wraps, tape, duct board, anywhere there is a duct or plenum connection?
  37. Replies
    21
    Views
    2,240

    My only concern with changing piston from 59 to...

    My only concern with changing piston from 59 to 57 is why did the compressor run quiet as a kitten for 4-5 days before it started the loud humm?? Seems like if the .002 difference in piston size is...
  38. Replies
    21
    Views
    2,240

    Thank you Duct Dr. Gonna put in a .57 and...

    Thank you Duct Dr. Gonna put in a .57 and vacuum to 500 microns and recharge.

    Will that really need a new filter dryer??
  39. Replies
    4
    Views
    831

    If my contractor does a piston swap (from 59 to...

    If my contractor does a piston swap (from 59 to 57) and then vacuums system to 500 microns does he also need to change filter dryer??

    week old system
  40. Replies
    21
    Views
    2,240

    going to change piston from .059 to .057 vacuum...

    going to change piston from .059 to .057 vacuum and recharge the system.
  41. Replies
    21
    Views
    2,240

    RUUD 2 ton UAKB 024JAZ condenser with Appolo SA...

    RUUD 2 ton UAKB 024JAZ condenser with Appolo SA 3024 air handler. Air handler came with .059 piston. Condenser compressor ran quiet as a mouse for 4 days and now its making a racket.

    RUUD manual...
  42. Replies
    4
    Views
    819

    Humidity reading based on Radio shack and...

    Humidity reading based on Radio shack and Bionaire gauge. Indoor RH yesterday ranged from 38 to 41.

    :)
  43. Replies
    4
    Views
    819

    1100 sq foot home in Va beach Va area. Faces SW....

    1100 sq foot home in Va beach Va area. Faces SW. Lots of lowE argon filled glass front and back. Black roof. Attic airhandler and duct work. 1 tree that really doesnt provide much shade.

    Yesterday...
  44. Thread: Duct Mastic

    by mikeinva
    Replies
    12
    Views
    1,201

    So the mastic can be applied right over the tape??

    So the mastic can be applied right over the tape??
  45. Replies
    5
    Views
    1,932

    If I close the ball valves to prevent hot water...

    If I close the ball valves to prevent hot water from migrating to the heating coil during Cooling season will condensation form on the heating coil as it cools and then fall under which there is no...
  46. Thread: Duct Mastic

    by mikeinva
    Replies
    12
    Views
    1,201

    My attic duct consists of 9ea 6" Silver R6 ducts...

    My attic duct consists of 9ea 6" Silver R6 ducts running off a 12 foot plenum made from Owens Corning 1 1/2 ductboard. The return is a 14" silver R6 flex.Everything is taped with the extra sticky...
  47. Replies
    11
    Views
    2,257

    Thank you sir :)

    Thank you sir :)
  48. Replies
    9
    Views
    1,270

    My RUUD UAKB 024JAZ condenser did not come with...

    My RUUD UAKB 024JAZ condenser did not come with an orifice?? The installer looked, I looked and there was none.

    The .059 orifice came with the Apollo SA3024 air handler.

    Can any of the pros...
  49. Replies
    11
    Views
    2,257

    Not to doubt you but is 1.5 H or J in fig 3???

    Not to doubt you but is 1.5 H or J in fig 3???
  50. Replies
    9
    Views
    1,270

    TXV valves arent unit/Brand specific?? A 2 ton...

    TXV valves arent unit/Brand specific?? A 2 ton txv valve can be used in any 2 ton system??
Results 1 to 50 of 77
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event