Search:

Type: Posts; User: Greend88

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    71
    Views
    3,634

    Here's some drawings to show everyone what your...

    Here's some drawings to show everyone what your talking about.
    http://sporlanonline.com/literature/10/210-60.pdf

    571901571911
  2. Replies
    43
    Views
    2,420

    https://www.youtube.com/watch?v=4SIk70l-TmE ...

    https://www.youtube.com/watch?v=4SIk70l-TmE

    Decided to search youtube after seeing your post, definitely looks a lot easier than I thought it would be.
  3. Thread: Hall effect

    by Greend88
    Replies
    14
    Views
    548

    http://www.usbr.gov/pmts/hydraulics_lab/pubs/wmm/f...

    http://www.usbr.gov/pmts/hydraulics_lab/pubs/wmm/fig/F14_08L.GIF

    http://www.usbr.gov/pmts/hydraulics_lab/pubs/wmm/chap14_06.html
    ...
  4. Thread: LASER LEVELS

    by Greend88
    Replies
    4
    Views
    441

    This is a good one if you lay out on the ground...

    This is a good one if you lay out on the ground with chalk lines. http://www.dewalt.com/tools/lasers--instruments-box-lasers-dw085k.aspx

    And this one is great for laying out vertical runs. And if...
  5. Replies
    3
    Views
    627

    Remember if the glove gets saturated with liquid...

    Remember if the glove gets saturated with liquid refrigerant you need to REMOVE it immediately to prevent frostbite. A glove will only protect you for a matter of seconds for a large spill.
  6. I agree with you and I doubt it'll ever get...

    I agree with you and I doubt it'll ever get enforced, Worst case people with High Returns won't get any tax return after a couple years when the penalty is real high. Hopefully this will help...
  7. "For the 2014 tax season, the Individual Shared...

    "For the 2014 tax season, the Individual Shared Responsibility fee for not having insurance is $95 per adult and $47.50 per child (up to $285 for a family), or 1% of your income, whichever is...
  8. I'm waiting to see what my Penalty is going to be...

    I'm waiting to see what my Penalty is going to be for last year I didn't have insurance but for a couple months because of lack of work And I wasn't going to pay the $800 month to keep my Policy...
  9. Replies
    17
    Views
    865

    I hear ya there, 3rd gen here too. I know for a...

    I hear ya there, 3rd gen here too. I know for a fact during the busy times when there's not enough guys they'll sell a card to anyone but when it dies back down none of them will be working and will...
  10. Replies
    17
    Views
    865

    I turned out at 23. I'm 26 Now and did my full 5...

    I turned out at 23. I'm 26 Now and did my full 5 years of apprenticeship. I think everyone should have to do at least one year even if you have 3-5 years experience. There are a ton of certifications...
  11. 304.3 Elevation of ignition source. Equipment...

    304.3 Elevation of ignition source.
    Equipment and appliances having an ignition source and located in hazardous locations and public garages, private garages, repair garages, automotive motor...
  12. You have to understand it's all about Liability....

    You have to understand it's all about Liability. Cell Phones are not Intrinsically Safe, Meaning that there is a chance of static or spark inside the phone (electric motor) to set off the gasoline...
  13. Here's the IMC 2012 and what I've always though...

    Here's the IMC 2012 and what I've always though it was.

    304.3 Elevation of ignition source.
    Equipment and appliances having an ignition source and located in hazardous locations and public...
  14. Replies
    39
    Views
    4,758

    Nice and Clean. I'm assuming it doesn't get below...

    Nice and Clean. I'm assuming it doesn't get below freezing there? Several things that wouldn't pass our code inspectors. First the thread protector as a Coupling, and too short of a drip leg, and No...
  15. Replies
    36
    Views
    1,687

    Concord and Armstrong are the same way. Step Bit...

    Concord and Armstrong are the same way. Step Bit is easier and faster.
  16. Replies
    15
    Views
    1,037

    http://www.rectorseal.com/index.php/rectorseal-tru...

    http://www.rectorseal.com/index.php/rectorseal-tru-blu/
  17. Replies
    148
    Views
    10,684

    I would of made it so you could put the flapper...

    I would of made it so you could put the flapper on either side.
  18. Replies
    13
    Views
    954

    Big Ass Fans and Infrared.

    Big Ass Fans and Infrared.
  19. Replies
    19
    Views
    1,677

    Mueller ACR Type K and L is rated for 410A and...

    Mueller ACR Type K and L is rated for 410A and Sub-critical CO2. It has a UL Rated 700psi working pressure.

    http://www.muellerindustries.com/uploads/pdf/UL_700_psi_Announcement.pdf...
  20. Replies
    12
    Views
    551

    If its that big of a job who wrote up the...

    If its that big of a job who wrote up the contracts? I would be blaming them for any mistakes
  21. Replies
    12
    Views
    551

    Venting can be either HVAC or Plumbing.... It's...

    Venting can be either HVAC or Plumbing.... It's in both there codes. If it's not in the plumbers contract you'll have to pay more for him to do it.
  22. Thread: Used furnaces

    by Greend88
    Replies
    72
    Views
    3,565

    I see used furnaces and even new furnaces on our...

    I see used furnaces and even new furnaces on our local facebook buy sale and trade groups all the time going for $ to $ bucks all the time. Heck I bought a 92% Condensing Lennox for $ nothing wrong...
  23. Thread: quote

    by Greend88
    Replies
    5
    Views
    627

    http://www.scotsman-ice.com/ Find your Local...

    http://www.scotsman-ice.com/ Find your Local Distributor and Talk to them. Top of the Screen is the link to search for Distributors
  24. Replies
    49
    Views
    1,844

    Throw the spare on drive slower to a repair shop...

    Throw the spare on drive slower to a repair shop and buy a new tire. Hope you don't expect to be compensated for sitting on your arse doing nothing....
  25. Replies
    11
    Views
    641

    Idk but I'm betting you'll be back to replace...

    Idk but I'm betting you'll be back to replace something else soon....
  26. Replies
    18
    Views
    1,740

    Home depot sells a Cheap Ridgid one for $79....

    Home depot sells a Cheap Ridgid one for $79. Basic and No Recording though. http://www.homedepot.com/p/RIDGID-Micro-CA25-Inspection-Camera-40043/203258908
  27. Replies
    11
    Views
    694

    They Make Nitro Cars/Trucks with Reverse.

    They Make Nitro Cars/Trucks with Reverse.
  28. Replies
    34
    Views
    3,998

    They make mini-android tablets for the guys with...

    They make mini-android tablets for the guys with flip phones. About the size of a smart phone and cheap. Should work well with this and any other new testing devices coming to the HVAC market for...
  29. Replies
    17
    Views
    1,582

    Our Local Amazon did the same thing a year ago....

    Our Local Amazon did the same thing a year ago. One of the company's i've worked for tried to get them to go with a centralized system but there argument was they just lease there warehouses and...
  30. Replies
    36
    Views
    1,905

    Tip: Get rid of the manifold and long hoses. Get...

    Tip: Get rid of the manifold and long hoses. Get Vac Rated Hoses and Connect Directly Pump to System.
  31. 5 months won't even teach you the basics. Look...

    5 months won't even teach you the basics. Look into your Local Apprenticeship. 5 Years down here and all you pay for is your Books each year which is only ~$300 bucks a year. Plus you get to work and...
  32. That Running Time meter would be the cheapest but...

    That Running Time meter would be the cheapest but if you want to know the actual cycles and whether there's any water in the pit at the correct level when it runs then I would use an Arduino....
  33. Replies
    35
    Views
    4,357

    And Compared to the accuracy of the BluVac's 5% ...

    And Compared to the accuracy of the BluVac's 5%
    http://www.accutools.com/product/bluvac-digital-vacuum-gauge/#3
  34. Replies
    21
    Views
    1,658

    TXV or Piston? Could have a slight restriction....

    TXV or Piston? Could have a slight restriction. Any kinks in the line set? Hows the drier?
  35. Replies
    48
    Views
    2,589

    Cast Iron Fittings Can Be Found under IFGC:...

    Cast Iron Fittings Can Be Found under IFGC: 403.10.4 - 5
    http://publicecodes.cyberregs.com/icod/ifgc/2000/icod_ifgc_2000_4_par042.htm

    Cast Iron Pipe is Prohibited.
  36. Replies
    48
    Views
    2,589

    The IFGC 2006 has the exact same thing under...

    The IFGC 2006 has the exact same thing under section 403.9
    http://publicecodes.cyberregs.com/icod/ifgc/2000/icod_ifgc_2000_4_par034.htm?bu2=undefined
  37. Replies
    48
    Views
    2,589

    http://www.detroitnippleworks.com/merchant-couplin...

    http://www.detroitnippleworks.com/merchant-couplings/

    Straight threads make them easy to loosen up with any type of vibration.

    The UPC 2003 Says For Fuel Gas Piping: "1209.5.7 Metalic Pipe...
  38. Replies
    15
    Views
    1,215

    Your Missing Something.... You make a loop...

    Your Missing Something.... You make a loop between the two heaters.
  39. Replies
    15
    Views
    1,215

    You can do it either Parallel or Series, both...

    You can do it either Parallel or Series, both have there pros and con's google it. And make sure to check with your Local Inspector as said above.
  40. Replies
    6
    Views
    434

    Yes you do need to be certified....

    Yes you do need to be certified. http://codes.ohio.gov/oac/1301:3-7-02

    And if you get caught here's the fine: http://codes.ohio.gov/orc/3703.21
  41. Replies
    10
    Views
    810

    Havn't Tried this but couldn't you take a dual...

    Havn't Tried this but couldn't you take a dual port manometer and cap off one port with a piece of plastic tubing with a valve. You can get them at aquarium shops. Place this tube on the manometer...
  42. Replies
    16
    Views
    1,411

    Oil Separator, and get it back to the compressor....

    Oil Separator, and get it back to the compressor. As long as it's not running 24/7 it won't hurt it. Seen Fridge Compressors last forever as airbrush compressors.
  43. Replies
    13
    Views
    1,478

    What did you set the Ice Thickness Probe? Should...

    What did you set the Ice Thickness Probe? Should be 9/32"

    http://www.manitowocice.com/asset/?id=pnvoq

    See Page 100 for setting Probe.

    "During the first 6 minutes of the freeze cycle the ice...
  44. Replies
    14
    Views
    1,108

    You could rewind a couple used 1200 watt...

    You could rewind a couple used 1200 watt microwave transformers (MOT's). I've seen it done to make cheap arc welders before. Just make sure there in phase and do the math to figure your winding size...
  45. Replies
    33
    Views
    3,892

    HS36 Gets my Vote Have had mine for over 2 years...

    HS36 Gets my Vote Have had mine for over 2 years and no problems at all.
  46. Replies
    19
    Views
    1,993

    Service Wrench and Extension Like everyone else...

    Service Wrench and Extension Like everyone else said ^
  47. Thread: Pulley puller

    by Greend88
    Replies
    33
    Views
    2,391

    Harbor Freight has a couple Hydraulic Pullers for...

    Harbor Freight has a couple Hydraulic Pullers for less than a $100

    http://www.harborfreight.com/catalogsearch/result?q=Hydraulic+Gear+Puller
  48. Replies
    45
    Views
    3,150

    Dont worry bout the teflon tape. I use it on all...

    Dont worry bout the teflon tape. I use it on all gas pipe never had a problem. As long as its put on correctly itll never get in the pipe.
  49. Replies
    22
    Views
    2,871

    The reason for no staybrite8 in commercial...

    The reason for no staybrite8 in commercial buildings on pipe systems would be to keep the joints from melting in a fire and introducing a ton of refrigerant.
  50. Replies
    45
    Views
    3,150

    All Appliances should be isolated, and the meter...

    All Appliances should be isolated, and the meter should be isolated before any pressure tests are done.
Results 1 to 50 of 417
Page 1 of 9 1 2 3 4

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine