  1. Replies
    11
    Views
    2,708

    I just bought that From RSD it is well built. I...

    I just bought that From RSD it is well built. I keep mine on the top shelf in the van and I have not used it yet. SOLID BUILD.
    Hope this Helps.
  2. Thread: PSI

    by N2fords
    Replies
    22
    Views
    886

    and move all lines around. i had a r-22 that I...

    and move all lines around. i had a r-22 that I could see oil everywhere yet 450 psig and still no leak until I moved a line and heard hisssing ... it was at the compressor on a discharge line factory...
  3. Replies
    33
    Views
    1,175

    also meters are sensitive to battery condition,...

    also meters are sensitive to battery condition, low battery gives false readings.
  4. putty knive to scrape the grease off. towels...

    putty knive to scrape the grease off. towels around the bottom to keep drips from running into the chase for wiring. also a shop vac, degreaser and hot water from a pump sprayer. then remove the fan...
  5. Replies
    8
    Views
    467

    Also check all wiring going to pressure controls....

    Also check all wiring going to pressure controls. Wires rubbing against copper tubing, pinched, or across the blower like carrier did. Inspect all Wires chances are there is a rub through. Also make...
  6. Replies
    42
    Views
    1,318

    had to ask! Alot of times it is overlooked. Glad...

    had to ask! Alot of times it is overlooked. Glad to hear that it was cleaned and checked . Carry on
  7. Replies
    42
    Views
    1,318

    are you sure the compressor valves are not weak....

    are you sure the compressor valves are not weak. you say the box is the problem it might be in the evap txv setting or weak compressors. coils clean you say, did you clean them or they look clean....
  8. Replies
    10
    Views
    544

    mid to upper 90's in Tucson Arizona.

    mid to upper 90's in Tucson Arizona.
  9. Replies
    28
    Views
    1,753

    Make sure the transformer on tranes are grounded...

    Make sure the transformer on tranes are grounded on the common side this will cause issue with Heat side of things seen it before. just saying!
  10. Replies
    18
    Views
    1,348

    does it have a reversing valve on it might be...

    does it have a reversing valve on it might be bleeding past!
  11. Replies
    29
    Views
    1,337

    Make sure the condenser coil is clean might not...

    Make sure the condenser coil is clean might not be rejecting enough heat!
    Can you pump it down and does it hold?
  12. Replies
    9
    Views
    714

    do a u tube search on tearing abart and cleaning...

    do a u tube search on tearing abart and cleaning your old vacuum pump you might be surprised at how well it will work again? congratulations on your new purchase.
  13. Replies
    35
    Views
    1,812

    My low side knob has peeled but still works...

    My low side knob has peeled but still works great...
  14. Replies
    35
    Views
    1,812

    Have had my digi- cool AK900 for over two years...

    Have had my digi- cool AK900 for over two years now and I replaced the velcro Straps for the clamps and love them.
    Highly Recomend them. I also Have 4 other Analog gauges but my go to is always the...
  15. Replies
    24
    Views
    1,440

    It has nothing to do with the manifold leaking it...

    It has nothing to do with the manifold leaking it has to do with the quickness of evacuation using just the hose and the APpion South core remover tool if you are how about course that's that's the...
  16. Replies
    17
    Views
    1,177

    All I use period

    All I use period
  17. Replies
    17
    Views
    1,177

    You are mistaken as paragon digital have...

    You are mistaken as paragon digital have desperate duration and if the power goes out it will keep the time.. best time clock out there..
  18. Replies
    24
    Views
    1,440

    I have pulled through my ak900 for small ric or...

    I have pulled through my ak900 for small ric or rif systems but I also own the Blu Vac Micron Gauge and appion core removal tool and Evacuation hose as well. it depends on the system and how dry it...
  19. Replies
    17
    Views
    1,177

    Replace those POS with a Paragon and be done with...

    Replace those POS with a Paragon and be done with them. The fail within a year. I am not impressed with Grasslin
  20. Replies
    16
    Views
    1,014

    Make sure to check drawer gaskets and rollers to...

    Make sure to check drawer gaskets and rollers to ensure proper sealing.
  21. Replies
    18
    Views
    1,038

    I only asked the question. so I could go even...

    I only asked the question. so I could go even deeper Into detail but you seem to have a grasp..
  22. Replies
    18
    Views
    1,038

    Side port can be used for micron gauge or to...

    Side port can be used for micron gauge or to attach charge hose.. are you new to this?
  23. Replies
    18
    Views
    1,038

    Want to see a big difference get the appion ...

    Want to see a big difference get the appion evacuation kit. I have one and I use two valve core removal tools. I hook up my appion to the big flare on my robinair 6 cfm 2 stage and the smaller...
  24. Replies
    5
    Views
    292

    Testo is a good camera

    Testo is a good camera
  25. Replies
    5
    Views
    292

    I have a testo but its old but works good for...

    I have a testo but its old but works good for checking it tight places.
    how much you want to spend determines quality
  26. Replies
    25
    Views
    1,379

    when was the last time you replaced the battery?...

    when was the last time you replaced the battery? Just a thought!
  27. Replies
    1
    Views
    272

    i like the H10 pm

    i like the H10 pm
  28. Replies
    2
    Views
    468

    I bet Positive and Neutral where reversed and you...

    I bet Positive and Neutral where reversed and you where see potential voltage always verify positive to ground to see which is in fact positive.
  29. Replies
    14
    Views
    1,002

    I had a store that ran propane floor buffers and...

    I had a store that ran propane floor buffers and when they changed tanks in the same area of the Walk-ins it would alarm. for about 2 minutes. just a thought!
  30. voltage can kill compressors as well. how are...

    voltage can kill compressors as well. how are they failing?
  31. Replies
    18
    Views
    1,176

    a crane is about 150. an hour so why would you...

    a crane is about 150. an hour so why would you need to throw out your back carrying a comp up a ladder. that said I have roped up compressors to roofs where its not going to get their any other way....
  32. Thread: NATE Exam

    by N2fords
    Replies
    22
    Views
    807

    congratulations on passing. Remember to write...

    congratulations on passing.
    Remember to write down the # of the questions that you don't know and skip them go on answering the ones you are positive about.
    then later go back and I bet you can...
  33. Replies
    13
    Views
    1,039

    someone might of done it out of meanness

    someone might of done it out of meanness
  34. Replies
    13
    Views
    1,039

    someone closed it they do not close themselves.

    someone closed it they do not close themselves.
  35. Replies
    20
    Views
    1,503

    was it sideways and the unit was supposed to be...

    was it sideways and the unit was supposed to be up? if the relay is not mounted correctly it can do this.
  36. Replies
    11
    Views
    1,126

    Digicol AK900 I love it get the clamp on sensors...

    Digicol AK900
    I love it get the clamp on sensors as the velcro ones are a pain.
    Hope this Helps,
    Bruce
  37. Replies
    10
    Views
    1,097

    I ordered my Digicool AK900, BluVac (more costly...

    I ordered my Digicool AK900, BluVac (more costly one, Nylog, Appion Evac hose and core tool, &FieldPiece SPD2.
    All From TTT they always deliver the best. I Have been Pleased and would recommend them...
  38. Replies
    51
    Views
    2,985

    I am Assuming everyone here know never adjust a...

    I am Assuming everyone here know never adjust a txv until the box is within 5 degrees of set-point, right?
  39. the H-10 is without a doubt an awesome detector...

    the H-10 is without a doubt an awesome detector but so is my ultrasonic. I use both it I cant find it with these then I need to different job.
    Fix your H-10 and adjust your heaters, change the...
  40. If he is a good customer then I would Charge a...

    If he is a good customer then I would Charge a trip charge to cover time and fuel. if its a first time caller then I would charge him full price.
  41. Replies
    13
    Views
    1,280

    is the blower close to it rated amps? whats your...

    is the blower close to it rated amps? whats your return and supply air temps? where did you take the superheat to achieve the 18 degrees?
  42. Replies
    15
    Views
    1,247

    TruTechTools,I just did another order with them...

    TruTechTools,I just did another order with them and wont use anyone else.
    I have done 3 large orders already and have never regretted any of it.
    Great Shipping Service and its a Brother HVAC....
  43. Replies
    28
    Views
    1,970

    real simple measure the temperature of the inlet...

    real simple measure the temperature of the inlet water of both units. water source could be two separate lines where only one is bleeding do to mixing valve in plumbing gone bad, ohm out the sensor,...
  44. Replies
    16
    Views
    1,521

    I own the Blue Vac and I have not had a problems...

    I own the Blue Vac and I have not had a problems with mine but then again I never pressurized mine! just saying
  45. Replies
    81
    Views
    7,432

    Thank you sir! it always surprises me how little...

    Thank you sir! it always surprises me how little some people do! think of every job as if your boss will be the next guy working on it. Should change how some people do things.
  46. Chrismartian1978 We are mostly U.S. Technicians...

    Chrismartian1978 We are mostly U.S. Technicians so we don't know your countries requirements. So take that into consideration before slamming others for viewing your post.
    Also talk to people who...
  47. Replies
    81
    Views
    7,432

    another Rookie Mistake is hooking up your gauges...

    another Rookie Mistake is hooking up your gauges and seeing a low suction pressure and thinking its low on charge.
    Check your fan is on. check the evap is it frozen? filter Dirty, Evap or Condenser...
  48. Replies
    81
    Views
    7,432

    I had the power off on a self contained unit to...

    I had the power off on a self contained unit to check A liquid line solenoid I used a magnet to cycle the liquid line.. forgot to put the solenoid on and plugged the unit in. I was inside the 1 door...
  49. Just want to say if the hole is not in the right...

    Just want to say if the hole is not in the right spot after drilling use a wooden dowel to fill the hole and then finish it with whatever your drilling threw..
  50. Replies
    24
    Views
    1,435

    this is just me, but I always Change capacitors...

    this is just me, but I always Change capacitors with new motors. Cond may look clean and still be dirty.
    Whats your Voltage, any drop across the contactor. all wires tight. Fan located in the well...
Results 1 to 50 of 126