02-15-2013, 10:28 PM
- Replies
- 8
- Views
- 693
Sorry just try http://csicubed then open...
Sorry just try http://csicubed then open products..
-
02-14-2013, 12:29 PM
- Replies
- 8
- Views
- 693
TenantEye by Csi3 is popular and easy to set up.....
TenantEye by Csi3 is popular and easy to set up.. Free 2 hr trial.. http://csicubed.com/portofolios/tenant-eye/
-
02-08-2013, 12:12 AM
Thread: CCN AX
by EMPadvocate- Replies
- 17
- Views
- 1,123
Thanks for the response. The serial device I'm...
Thanks for the response. The serial device I'm looking at also does TCP/IP (B&B-elec VESR901) also so I'm going to have to play with it.
Evidently the CCN workstation has to be setup for a... -
02-06-2013, 11:54 AM
Thread: CCN AX
by EMPadvocate- Replies
- 17
- Views
- 1,123
I have a customer with CCN and multiple bldgs...
I have a customer with CCN and multiple bldgs connected to the 0 network. They have issues with the underground between buildings and my thought was using serial RS485/ethernet converters with the...
-
02-06-2013, 10:49 AM
Thread: Metasys closed N2 protocol.
by EMPadvocate- Replies
- 9
- Views
- 702
Maxline (who picked up Infocon driver line) has...
Maxline (who picked up Infocon driver line) has an N2 driver for Tridium (ibmsN2.jar) that works very good.. I would add the external RS485 comm port card though to the JACE and add separate networks...
-
08-01-2012, 10:46 AM
Thread: controls tech, no truck?
by EMPadvocate- Replies
- 24
- Views
- 2,041
Current US IRS defines mileage expense as...
Current US IRS defines mileage expense as .55/mile; sorry for you guys getting paid .50/mile; your company is making .05/mile on you and maybe the IRS needs to know about that.. I always thought...
-
08-01-2012, 10:20 AM
Thread: Trane LCI-R Bacnet
by EMPadvocate- Replies
- 11
- Views
- 964
If you're using Tridium you can change the out of...
If you're using Tridium you can change the out of service attribute using the virtual gateway; this will stay in the BCI config unless its blown out back to default..
-
01-18-2012, 11:10 AM
Thread: CCN to Modbus
by EMPadvocate- Replies
- 5
- Views
- 363
Thanks, I dont have a variable SCHEDNUM or MODE...
Thanks, I dont have a variable SCHEDNUM or MODE in the printout.. There are no jumpers on the terminal block.. I am starting to believe RMTOCC is addressed wrong in the printout. I need to look at it...
-
01-17-2012, 11:06 AM
Thread: CCN to Modbus
by EMPadvocate- Replies
- 5
- Views
- 363
Thanks, RMTOCC (0x400F) is at 1 and is not...
Thanks, RMTOCC (0x400F) is at 1 and is not responding to a write command; I have set OCCPC01S (0x9000) to 0 and also cleared all registers to 0x9008 which I believed cleared all three events...
-
01-16-2012, 05:32 PM
Thread: CCN to Modbus
by EMPadvocate- Replies
- 5
- Views
- 363
CCN to Modbus
I have a 33CNTRAN485 in modbus mode on a 50EJ RTU. The printout from the Comfortview SW had "C48/50E Standard Tier Rooftop" in the status display pages and "C48/50E Standard Tier Rooftop -0,2" in...
-
08-15-2011, 02:15 AM
- Replies
- 13
- Views
- 1,536
After integrating a few server farms I feel that...
After integrating a few server farms I feel that some IT managers pushed into facilities/sustainability aren't qualified or experienced enough to actually make the initial correct decisions as to an...
-
04-27-2011, 12:25 PM
Thread: Reliatel Analog DAT control
by EMPadvocate- Replies
- 0
- Views
- 254
Reliatel Analog DAT control
Anyone have experience doing VAV supply air cooling setpoint on the RTRM board using an analog DCV? The literature also says that this can be accomplished on the RTAM board.. What will yield the best...
-
04-27-2011, 11:20 AM
Thread: Anyone use the new BCI-R yet?
by EMPadvocate- Replies
- 13
- Views
- 1,103
You need the software from Trane to talk to it...
You need the software from Trane to talk to it with USB cable; SW is actually pretty well done.. The MAC addresses mean nothing to BACnet MS/TP you actually have to enable it to use it (checkbox);...
-
02-16-2011, 12:49 PM
Thread: PLC
by EMPadvocate- Replies
- 30
- Views
- 2,985
The base DL06 has 3 slots open for analog I/O...
The base DL06 has 3 slots open for analog I/O since one is used for the ECOM100 ethernet device. You can add another modbusTCP device in the ECOM100 configuration or another DL06 or a gateway and...
-
02-16-2011, 12:34 PM
Thread: Alerton Integration
by EMPadvocate- Replies
- 9
- Views
- 998
You need to license BACnet IP and everything...
You need to license BACnet IP and everything BACnet is out on eth1 which you designate as part of the configuration. I just did a HW job with the new BACnet spyders using 3 of the Contemporary...
-
02-16-2011, 01:39 AM
Thread: PLC
by EMPadvocate- Replies
- 30
- Views
- 2,985
I use the Automation Direct DL06 for central...
I use the Automation Direct DL06 for central plant work using Turbocors and VSDs. I use the com2 port for direct compressor control and the ECOM100 card for modbusTCP talking to a JACE.. For the VSD...
-
02-16-2011, 01:10 AM
Thread: Alerton Integration
by EMPadvocate- Replies
- 9
- Views
- 998
Doing MS-TP using onboard RS-485 on a large...
Doing MS-TP using onboard RS-485 on a large network distributed over 4 com ports??? Well good luck with that.. Thats something I wouldn't consider with a JACE. JAVA is built on top of IP and is most...
-
12-15-2010, 11:09 AM
Thread: touch screen (text) interface
by EMPadvocate- Replies
- 14
- Views
- 694
Engenuity.com is also picking up a lot of BACnet...
Engenuity.com is also picking up a lot of BACnet product.. They had a new display product I wanted to look at
-
12-15-2010, 10:46 AM
Thread: NCM Battery
by EMPadvocate- Replies
- 8
- Views
- 1,099
Interstate Batteries has these.. Try #NIC0088...
Interstate Batteries has these.. Try #NIC0088 which I took off the package..
They were the JCI suppliers; -
12-14-2010, 01:02 PM
Thread: Webs Bacnet Class
by EMPadvocate- Replies
- 4
- Views
- 588
If you know Spyders you should'nt have much of a...
If you know Spyders you should'nt have much of a problem.. just blow out all the nvi, nvo, nci lon network points before you pull in a app off the palette and then re-add - for boolean I used...
-
08-03-2010, 12:57 AM
Thread: AX tunnelling for Metasys CCT
by EMPadvocate- Replies
- 9
- Views
- 1,504
I am thinking the AX/FX JACE product can't tunnel...
I am thinking the AX/FX JACE product can't tunnel over the serial port. Perhaps you can use a usb to ms/tp (BASRTP-B from ccontrols.com) from the OWS you have. Don' t have a copy of CCT yet so I...
-
02-28-2010, 01:15 AM
Thread: Turbocor Help:Ask Questions
by EMPadvocate- Replies
- 58
- Views
- 7,178
OPC, sounds like your machine is upside down with...
OPC, sounds like your machine is upside down with evap temp higher than cond side; compressor is in demand limit and won't take off. Hot gas bypass (HGB) will help with these situations.. Use the TC...
-
08-23-2009, 12:42 PM
- Replies
- 34
- Views
- 1,774
I might be mistaken but I did'nt see anything in...
I might be mistaken but I did'nt see anything in the this discussion about the issues with duo-core PCs and USB serial port devices. Personally I had issues with the off-shore devices (Frys) with my...
-
04-09-2009, 09:45 PM
- Replies
- 3
- Views
- 405
If you find a clean way to read the compressors...
If you find a clean way to read the compressors individually please share it.. I had to write the comp selector as a numeric write and the exec a program object on a numeric point using the same...
-
10-13-2008, 04:08 PM
Thread: Trane LciDac Issue
by EMPadvocate- Replies
- 6
- Views
- 595
I solved the issue by taking Willf650's advice...
I solved the issue by taking Willf650's advice and wrote a value of the average space temp to nviSpaceTemp and setting occupied space temp setpoints. Writing nviAplicMode would not trigger the heat....