Search:

Type: Posts; User: Senior1

Search: Search took 0.00 seconds.

  1. What were your pressures? Air cooled? Cycling...

    What were your pressures? Air cooled? Cycling cond fan? Headmaster?

    Head pressure change? We're you measuring at the comp leads or breaker?
  2. Replies
    6
    Views
    787

    Agree

    Agree
  3. Replies
    54
    Views
    3,853

    You are reading a voltage drop across a load like...

    You are reading a voltage drop across a load like a CCH, wired to line side of contactor. Meter making the circuit, or grounded side of control transformer.
  4. Replies
    10
    Views
    1,624

    Old rule of thumb! RA=, 1 sq ft/ton@400cfm/ton

    Old rule of thumb! RA=, 1 sq ft/ton@400cfm/ton
  5. Replies
    42
    Views
    2,745

    Nail head, meet hammer, ;-)

    Nail head, meet hammer, ;-)
  6. Replies
    35
    Views
    2,484

    Thought we were talking a/c, my bad.

    Thought we were talking a/c, my bad.
  7. Replies
    35
    Views
    2,484

    Remember, more moisture removal=less dry blub...

    Remember, more moisture removal=less dry blub temp split. (latent vs sensible stuff)

    That said, generally, slightly low sub cooling and slightly high superheat
    = slightly low freon. Ya, need wet...
  8. Replies
    35
    Views
    2,484

    Does not compute........ Adding heat to evap...

    Does not compute........ Adding heat to evap increases subcooling?
  9. Replies
    42
    Views
    2,745

    newbie here, common suction? How is the oil...

    newbie here, common suction? How is the oil separator piped and is the oil pressure switch wired correctly? Unloading? Staged? Pump down or selinoid drop? Just thinking out loud.
  10. Manufactures could care less how hard it is for...

    Manufactures could care less how hard it is for you to get that info. They would rather you sell a unit.

    Careers are made at the factory level by saving a nickel per unit.

    Another question,...
  11. Replies
    34
    Views
    4,384

    high superheat an low SC,,, add two lbs and get...

    high superheat an low SC,,, add two lbs and get back to us. Remember a txv is a constatant superheat device, if you add freon and the SH starts going down, you were flashing in the LL . 40 ft is...
  12. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    7,704

    feast and famine, nature of the beast, did it for...

    feast and famine, nature of the beast, did it for decades, save in the summer, hunt n fish in the spring fall.

    We even hade one tech that would go to job sites and let freon out systems so he...
  13. Walmart window unit in the bedroom is your...

    Walmart window unit in the bedroom is your friend. I keep an old one in the garage, same price as putting wifey up in a motel for one night.
  14. Replies
    15
    Views
    2,141

    Hygroscopic =hyDroscopic, damn computer!

    Hygroscopic =hyDroscopic, damn computer!
  15. Replies
    15
    Views
    2,141

    Which is the reason I recommend HOs that have a...

    Which is the reason I recommend HOs that have a good r22 system keep them. POE are bad juju with moisture. Did anyone mention POEs are 5 times more hygroscopic as mineral oil. (or was that 10 times)
  16. Replies
    27
    Views
    1,707

    You are correct, same in the south. Clean the...

    You are correct, same in the south.

    Clean the cond/evap/blower wheel of an old system, you just saved the same amount as new system. (all else being same, correct charge, air flow,etc.)

    I have...
  17. Replies
    16
    Views
    1,506

    LOL,,that made me laugh, I remember a GE RTU,...

    LOL,,that made me laugh, I remember a GE RTU, about 50 ton HP in the 80's or so, opened the panel and all black wires with 30 relays:gah:
  18. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    7,704

    Yep, big company I worked for had high school...

    Yep, big company I worked for had high school kids doing PMs, and polishing the OD unit so it looked like they did something. Old people, I do many for free on my time.
  19. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    7,704

    Heating,,, gas,,,,PM? Yes, Have a good night ;-)

    Heating,,, gas,,,,PM? Yes, Have a good night ;-)
  20. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    7,704

    Delta t CHANGE on a known working system is good...

    Delta t CHANGE on a known working system is good info for the home owner to monitor THEIR system, any change, call me.

    The problem is we techs have been pushed to SELL, SELL,SELL! The high seller...
  21. Replies
    16
    Views
    1,187

    LOL,,, I have seen leaving the txv bulb hanging...

    LOL,,, I have seen leaving the txv bulb hanging out in the attic considered a fix by some:gah:
  22. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    7,704

    Forgot to add, I have seen just as many new...

    Forgot to add, I have seen just as many new system failures as old.
  23. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    7,704

    You just stated the problem, most RESIDENTIAL...

    You just stated the problem, most RESIDENTIAL PM's are for cash flow only. I'm sorry to jump in late, but I agree with Flash, I also have over 20 yrs exp.

    If you have an old draft type gas...
  24. Replies
    25
    Views
    3,190

    Heat rise is good for ele heat fan coils except...

    Heat rise is good for ele heat fan coils except in the summer. If its 95 outside and you are troubleshooting, last I want to do is heat the customers already hot house up more. I have a electronic...
  25. Replies
    21
    Views
    1,546

    Carrier heating check chart, model will change...

    Carrier heating check chart, model will change info of course.

    http://www.xpedio.carrier.com/idc/groups/public/documents/techlit/38ydb-1xa.pdf


    Ps, read small print
  26. Replies
    47
    Views
    6,016

    Can it count towards CE credits I am required by...

    Can it count towards CE credits I am required by state to pay someone for?
  27. Replies
    16
    Views
    1,187

    He said another tech had been out last summer......

    He said another tech had been out last summer... Just saying
  28. Replies
    16
    Views
    1,187

    Cycling on low pressure switch?, there is a...

    Cycling on low pressure switch?, there is a screen on thr inlet of the txv, this can clog with trash causing your problem. If txv can be removed, clean it, if it's brazed in, you are going to need (a...
  29. Replies
    53
    Views
    3,823

    No insult intended, if you know this, but check...

    No insult intended, if you know this, but check your Gauges against a known pressure, (check temp of near full bottle of freon, convert to pressure, attach gauges
  30. Replies
    53
    Views
    3,823

    Is this a matched system? (3 ton cond/evap,...

    Is this a matched system? (3 ton cond/evap, etc)Measure CFM at R/A and it sounds like oversized metering device plus low air flow in evap and Gage's/thermometer may be off.
  31. Replies
    11
    Views
    2,394

    Review on amazon : 3.0 out of 5 stars...

    Review on amazon :


    3.0 out of 5 stars disapointed
    book not what I anticipated, not much on refrigerated systems, good if you want to learn the overall operation on normal hvac systems....
  32. Replies
    40
    Views
    3,147

    If you are not using a digital thermometer as...

    If you are not using a digital thermometer as basic tool, you are a shade tree.
  33. Replies
    21
    Views
    1,546

    This is for when charge is questioned. Dirty...

    This is for when charge is questioned. Dirty coils, non condensibles, etc will make all else guess work.
  34. Replies
    21
    Views
    1,546

    Name plate charge, recover, weigh in said amount...

    Name plate charge, recover, weigh in said amount plus any for lines over 15 feet. Old units, unit charge was figured using 25 foot line set.
  35. Thread: New Member

    by Senior1
    Replies
    15
    Views
    3,684

    Just saying hi

    I remember working on R500 residential units.
Results 1 to 35 of 40