    Now that my friend is quite an impressive...

    Now that my friend is quite an impressive document.
    Thanks you.
  2. Replies
    22
    Views
    1,799

    L99H0313M Is that serial # correct. I could not...

    L99H0313M
    Is that serial # correct. I could not find that #.
  3. Replies
    22
    Views
    1,799

    Lift is the difference between the evap. ref....

    Lift is the difference between the evap. ref. pres. and the cond. ref. pres.
  4. Replies
    22
    Views
    1,799

    I would have to guess by the size that the...

    I would have to guess by the size that the machine is fairly old (don't see to many small machines being commisioned now days) Need the first three digits of the serial #.

    But if it is a current...
  5. Replies
    10
    Views
    985

    Good point. I hope that it was a misprint,...

    Good point.
    I hope that it was a misprint, because the one that I did with those instructions I called it done at 9.
  6. Replies
    10
    Views
    985

    check this out.

    check this out.
  7. Replies
    12
    Views
    1,589

    Check your email.

    Check your email.
  8. 60872 Or try this you said that you are in the...

    60872

    Or try this you said that you are in the 8th grade??????????/
    Maybe the first was a little to simple for you.
  9. 60862 Check this out. If you put your email...

    60862

    Check this out.
    If you put your email in your profile bigger things can be sent.
  10. Thread: CVHF ???

    by triggerhappy
    Replies
    15
    Views
    1,501

    Carrier Mech, I got my motor out yerterday and I...

    Carrier Mech,
    I got my motor out yerterday and I took some good pics. of the discharge volute flange surface that where the oring seats.
    Purposely I took the pics. very big aprox. 2 meg. so that...
  11. Thread: CVHF ???

    by triggerhappy
    Replies
    15
    Views
    1,501

    Glad to hear that the job went well. It is bad...

    Glad to hear that the job went well. It is bad that the kit was misleading with the extra parts.

    I will have my next motor out by Wed. or Thurs. of this week and it is an 97 and I am sure that it...
  12. Thread: CVHF ???

    by triggerhappy
    Replies
    15
    Views
    1,501

    You should be able to push the motor up to the...

    You should be able to push the motor up to the flange by hand if it is floating on the guide bolts. The fit is not that tight it should push up right against the flange. Expecially with that small of...
  13. Thread: CVHF ???

    by triggerhappy
    Replies
    15
    Views
    1,501

    There is not a grove on the motor you just slide...

    There is not a grove on the motor you just slide the oring over the end of the motor and there is a lip on the discharge volute that the oring goes up into.

    That is to say that there is a lip that...
  14. Thread: CVHF ???

    by triggerhappy
    Replies
    15
    Views
    1,501

    From what I see this machine does in fact have an...

    From what I see this machine does in fact have an oring for the motor to discharge volute.
    It is # 29 in the lit. that came in the motor change out kit. There should be 2 different orings in the kit...
  15. I am not sure what you are asking. My example...

    I am not sure what you are asking.
    My example was with the pump off.
    Still the pump only has to have the head to overcome the resistance in the loop like piping losses, coil drops, chiller drop....
  16. For every 2.307 ft of head in the water pipe...

    For every 2.307 ft of head in the water pipe equals 1 psi.
    The pump is mearly overcoming the resistance in the loop.
    If you turn off the pump you will get your standing static pressure.
    It could...
  17. Thread: Helium?

    by triggerhappy
    Replies
    9
    Views
    950

    There are companies that you can get to rent...

    There are companies that you can get to rent their equiptment and operator.
    The one we use is from up north somewhere, we have used a couple of times on absorbers.

    I have also seen it used on...
  18. Replies
    3
    Views
    565

    It does not come standard with either Comm4 or...

    It does not come standard with either Comm4 or Comm5.

    It is and option and you have to select if you want the Comm module to be 4 or 5 when you order.

    You can bind and program either one in.
    ...
  19. Replies
    5
    Views
    579

    That's right..... of course you can pay an arm...

    That's right..... of course you can pay an arm and leg from Trane and it will have a cool little logo on it. :)
  20. Replies
    5
    Views
    579

    I would suggest that you get the Literature on...

    I would suggest that you get the Literature on Techview and CH530.

    They will tell you step by step how to do what you want to do.

    It is pretty involved if you are starting from scratch.(way to...
  21. Replies
    7
    Views
    868

    I hope that what I replied was not confusing. ...

    I hope that what I replied was not confusing.

    The KIT07957 is the splice kit that contains two connectors, tube of glue, several end caps and about 12 inches of cable.

    That is what I buy in...
  22. Replies
    7
    Views
    868

    kit07957 that is the # for the kit you need to...

    kit07957
    that is the # for the kit you need to splice in a llid.
  23. Replies
    10
    Views
    709

    Wtih the $ amounts that you described. My...

    Wtih the $ amounts that you described.

    My suggestion would be to take it to the motor shop and let them remove the impeller.
  24. Replies
    2
    Views
    391

    My guess is that you need to update the software....

    My guess is that you need to update the software.

    There was a version of software that would loose configuration and both machine start and hours along with purge pumpout time on power failure
  25. Replies
    2
    Views
    577

    I assume you are talking about this in relation...

    I assume you are talking about this in relation to Commissioning of a controls job.

    If so maybe you would get more response out of the Controls Forum.