  1. Replies
    35
    Views
    2,385

    Hey Tecgeek, I service your area and my family...

    Hey Tecgeek,

    I service your area and my family run business has for the past 61 years.

    I have installed and serviced geothermal for almost 26 years now...we have installed acadia and now the...
  2. Replies
    26
    Views
    4,806

    Looks similiar to a problem we had with a...

    Looks similiar to a problem we had with a 4TWX5030 that was installed summer of 2008. The HP would constantly go in and out of defrost all winter during the coldest days. Bottom of outdoor coil would...
  3. What brand did I switch too? Trane, and as...

    What brand did I switch too?

    Trane, and as previous threads remark it is all about the distributer- customer support.

    We are very happy, enjoying our best years ever, since my father started...
  4. I dropped Lennox after 28 years of loyalty. ...

    I dropped Lennox after 28 years of loyalty.

    Looking back it started shortly after the company went public. The bean counters focused on the bottom line and not the customer.

    Inventory was...
  5. Replies
    14
    Views
    1,101

    I have no idea if they are sizing it correctly. I...

    I have no idea if they are sizing it correctly. I am not there.

    The equipment is only as good as the duct system that will deliver the energy to the space.

    It is your job to interview the...
  6. Replies
    14
    Views
    1,101

    From reading your post, I would look for a...

    From reading your post, I would look for a contractor that understands air flow. Ask for a contractor that will inspect, test and record the airflow.

    Check out the National Comfort Institute web...
  7. Replies
    8
    Views
    1,048

    We had a similair experience about 20 years ago...

    We had a similair experience about 20 years ago with a new construction job. Well was drilled and clear, clean water was found. So we installed the HP as a WSHP a 3 -ton Waterfurnace. Home was...
  8. Replies
    45
    Views
    20,050

    Do not be so quick to blame the equipment. 70% of...

    Do not be so quick to blame the equipment. 70% of a quality installation is the responsibilty of the contractor with the installation. 20% is the box and 10% the customer.

    In Glen's case, I have...
  9. Replies
    17
    Views
    1,033

    cracked coil, loss of refrigerant, system run dry...

    cracked coil, loss of refrigerant, system run dry , 6 year old HP26 = probably have "green slime" internally and causing the restriction.

    Your tech is givng you good advice to replace the whole...
  10. Replies
    875
    Views
    91,119

    I can only walk on water during the winter when...

    I can only walk on water during the winter when it is frozen- AKA ice.
  11. Replies
    875
    Views
    91,119

    One of our biggest challenges selling HVAC...

    One of our biggest challenges selling HVAC equipment is to give the customers a chance to "kick the tires".

    That is why word of mouth is so helpfull and a primary focus with our company.

    Yet...
  12. Replies
    875
    Views
    91,119

    We are now 23 pages deep, lots of good advice,...

    We are now 23 pages deep,
    lots of good advice,
    even more crap advice from others,
    system still not corrected, HO going to have to live with it and the electricity bills.



    and then people ask...
  13. Replies
    875
    Views
    91,119

    Lets review, a new vertical bore in PA.,...

    Lets review,

    a new vertical bore in PA., Questionable install practises.
    It is now late Nov, early Dec, EWT at 32F.
    Still have another 3 months of the coldest winter to go through and your loop...
  14. Replies
    875
    Views
    91,119

    Scary thought, How many more loops have they...

    Scary thought, How many more loops have they done this way?

    Hopefully they take ownership and correct the problem.

    Have you talked to the distributor yet? They should be involved and...
  15. Replies
    875
    Views
    91,119

    Jongig, Another way to say "reverse return"...

    Jongig,

    Another way to say "reverse return" would be "first off- last on".

    So, on the side of the tee #2 (first off) follow the pipe out and back and it should be connected onto the end of...
  16. Replies
    875
    Views
    91,119

    Jongig, your last pic with labels shows us...

    Jongig,

    your last pic with labels shows us that the loops are NOT piped in the required "Reverse return method" as Robo was talking about.

    Loop two will get all / majority of the flow. You...
  17. Replies
    25
    Views
    1,905

    Huck check your PM's in the other forum.

    Huck check your PM's in the other forum.
  18. Home Depot..... Lately they have been running...

    Home Depot.....

    Lately they have been running with the moto " You can do it- We can help".

    Guess it is time to ask HD for help.......but I have a hunch you will need a pro.
  19. Replies
    18
    Views
    1,580

    Have to agree with the Lennox pain. We were a...

    Have to agree with the Lennox pain. We were a Lennox dealer for 28 years. Grew up with the Pulse. Started to get some grey hair with the Complete heat. Lost my religion over the TX valves. When...
  20. Replies
    3
    Views
    1,020

    Coil in the RA drop makes a lot of sense to have...

    Coil in the RA drop makes a lot of sense to have both furnace and Heat pump working together for more efficiency/ energy savings. Most manufactures will not warranty Hx with that set up. With the new...
  21. Replies
    19
    Views
    890

    I suggest you look at all options before you...

    I suggest you look at all options before you purchase testo. I have owned 4 different sets in the past 2 years. All sets have leaked out of the service valves. 2 sets have been returned for service...
  22. Replies
    14
    Views
    1,528

    Redoing a hacks job? I will always look at it...

    Redoing a hacks job? I will always look at it and price it accordingly

    - we always make more $$$ cleaning up a mess than if we had sold and installed the job in the first place. That is when I...
  23. Replies
    2
    Views
    683

    Project starts mid to end of January, 2008. 4...

    Project starts mid to end of January, 2008.

    4 flights home per year included as required.

    Throw away the heavy coat, mitts and long johns- work in the islands where you can fish , swim and...
  24. Thread: Lennox or Not

    by jthom
    Replies
    9
    Views
    822

    You should ask other Lennox dealers face to face...

    You should ask other Lennox dealers face to face what their opinion would be- you will get a better explanation than any reply on a public forum.
  25. Replies
    2
    Views
    683

    A/C and duct Installer for Abacos Project

    18 month project for "Condo" style new construction. Starts jan. 2008. 1.5 thru to 7.5 ton split equipment with exhaust fans and controls. All Trane high end equipment.