Search:

Type: Posts; User: Clocker

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    4
    Views
    341

    A/C Efficiency on 1st Stage vs. 2nd Stage

    Hi-

    Saw another post that made me wonder about A/C units.

    If you have a 2-stage AC unit, at what speed is the SEER rating at? The speed of the first stage or the speed of the second stage? ...
  2. Exchange Original Evolution Control for Evolution Connex

    Hello-

    Is there good place to get one of these Evoluation Connex controllers for a good price? It has some cool features. Is it an easy drop in replacement for my current Evolution controller?
    ...
  3. Replies
    4
    Views
    630

    It has been a while since I logged in here & I...

    It has been a while since I logged in here & I just saw the reply here.. Just wanted to say thank you for the feedback, motoguy!

    I don't believe my outdoor unit is communicating but I have...
  4. Replies
    4
    Views
    630

    Evolution Airflow with Single Stage AC

    Hello Gents-

    I have an Evolution 3 stage 80K BTU gas furnace with the Evolution Controller. My AC unit is a single stage 2.5ton Bryant unit.

    On the Evolution controller under Furnace settings...
  5. I was thinking white vinegar rather than bleach. ...

    I was thinking white vinegar rather than bleach. Wha-do-ya think?
  6. Long Flexible Brush for Cleaning Condensate Trap/Line

    Hi- I have a condensate trap coming off the air handler for my AC as well as a condensate drain line coming from my high efficiency furnace. The two drains end up connecting and drain into 3/4" PVC...
  7. Exhaust Pipe Loose, Condensate Leaked Into Furnace

    I noticed water collecting underneath my Bryant Evolution 3-stage natural gas furnace. Popped her open and noticed that the installers had not tightened up the hose clamp at the exhaust pipe...
  8. Replies
    12
    Views
    1,401

    Tech was out. My unit is operating normally. He...

    Tech was out. My unit is operating normally. He said he called Bryant and their tech. support told him that on cooler days (<63F) there's an imbalance of pressure in the system somehow related to...
  9. Replies
    12
    Views
    1,401

    Thanks. One thing I have found is that the...

    Thanks.

    One thing I have found is that the line-set is rigidly connected to the outside wall (concrete used to fill the hole) instead of the method shown in Fig. 1 page 1 of the install manual...
  10. Replies
    12
    Views
    1,401

    Sent the video to my installer last night prior...

    Sent the video to my installer last night prior to them coming out today. He said it sounded like the 'valves are shutting'. Not sure what that means though! :confused:

    Tech will be out...
  11. Replies
    12
    Views
    1,401

    I'm working on getting my contractor out but...

    I'm working on getting my contractor out but wondering if any of you guys want to take any guesses as to what the sound is:

    http://www.youtube.com/watch?v=GuYsDH6QSog

    It's at about 8-9 seconds...
  12. Replies
    12
    Views
    1,401

    Loud Click/Clunk when Condenser Shuts Off

    I have only heard my newer (2-month old) Bryant 116B do this twice. And it only seems to do it when it is cool outside like I describe below.

    Last night it was about 65F outside, the...
  13. Replies
    9
    Views
    1,932

    My installer told me to use white vinegar, not...

    My installer told me to use white vinegar, not bleach.
  14. What about one of these for the intake (if not...

    What about one of these for the intake (if not bent over 90-degrees) and/or exhaust?

    http://savepipey.net/
  15. Replies
    6
    Views
    581

    ~43% SE Michigan Thanks!

    ~43%

    SE Michigan

    Thanks!
  16. Replies
    6
    Views
    581

    FWIW: Air Handler: Bryant CAC/BDP CNPVP3617ACA...

    FWIW:

    Air Handler: Bryant CAC/BDP CNPVP3617ACA
    Outside Unit: Bryant 116BNA036000

    Thanks!

    Clocker
  17. Replies
    6
    Views
    581

    Thanks for your feedback. Would the...

    Thanks for your feedback.

    Would the 350CFM/ton setting be more efficient at cooling that the 325CFM/ton setting for my 3ton unit (assuming the difference in humidity is negligible)?
  18. Replies
    6
    Views
    581

    Evolution AC Airflow Setting

    Howdy guys-
    I have an Evolution furnace (355CAV 80K BTU) with Evolution control. My AC unit is just a single stage 3-ton (non-Evolution) Bryant 116B.

    I have 4 settings on the stat for airflow...
  19. I ended up mounting my own box on the N side of...

    I ended up mounting my own box on the N side of the house and running a 2-wire from it to the furnace myself. My installers electrician came over this AM and pulled the sensor out of the AC unit and...
  20. Replies
    11
    Views
    2,140

    Intake & Exhaust Pointing Down

    Hey guys-

    Just wondering...why not have a downward fitting so the exhaust points down similar to the intake? Seems like that would be a good way to prevent crap from getting into the exhaust...
  21. Replies
    11
    Views
    2,140

    I think my Evolution controller said my static...

    I think my Evolution controller said my static number was 0.42...? Is that the number you're looking for?

    The furnace is a 355CAV 80K BTU (95%).

    AC is a Bryant 116B 3-ton (up to 16.5 SEER).
  22. I think I'll run my own wires and mount the...

    I think I'll run my own wires and mount the sensor on the N side of my house. But I'll ask my installer to connect the wire to the control board. I'm nervous about going inside the furnace if I...
  23. The sensor is inside the upper section of the AC...

    The sensor is inside the upper section of the AC cabinet clipped to the vertical wall inside the compartment where the big relay and other connections are made. I agree it can never give an accurate...
  24. Thanks for posting! Wish I knew what to look...

    Thanks for posting! Wish I knew what to look for. How big are they? Is it located somewhere near where the lines go into the condenser unit on the Evolution units?

    Thanks!
  25. Kinda though so. But was also thinking that it...

    Kinda though so. But was also thinking that it probably gets shade inside the air condition unit. However, it probably gets hotter inside that confined area nonetheless. Guess I'll give it a week...