Search:

Type: Posts; User: MeĞiC

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: SKYRIM!!!!

    by MeĞiC
    Replies
    16
    Views
    1,253

    must....resist.......... restarting.......

    must....resist.......... restarting.......
  2. Replies
    23
    Views
    1,784

    I gotta ask, why 8' tall box? Is it something...

    I gotta ask, why 8' tall box? Is it something they have?

    My concern would be the clearance under the evap drains.
  3. Replies
    23
    Views
    1,784

    77'x10'x8' box with 30 doors would have a 64,000...

    77'x10'x8' box with 30 doors would have a 64,000 btuh requirement (based on 3.5" walls & T8 lighting on the doors). Considering the length and 30 doors, I would go with eight 9,000 btuh evaps.
    ...
  4. Replies
    30
    Views
    3,033

    We recently removed one of these cases because it...

    We recently removed one of these cases because it would not hold temp on the ends.

    I agree with jp. Reduce the defrosts to 4x a day. 30min duration is plenty.

    As icemeister indicated, shelf...
  5. Thread: PMs for racks

    by MeĞiC
    Replies
    26
    Views
    3,106

    :gah:

    :gah:
  6. Replies
    6
    Views
    1,347

    I'd be more concerned with the condenser being...

    I'd be more concerned with the condenser being oversized.
  7. Replies
    24
    Views
    5,834

    Expect it to triple come February. Can't even buy...

    Expect it to triple come February. Can't even buy bulk quanities from most vendors. EPA required a 40% manufacturer reduction last week (originally was just 10% Jan 1) because the phase out isn't...
  8. Replies
    1
    Views
    562

    NRF/RCA Doors 1775 btu/door -22°F (evap temp)...

    NRF/RCA Doors
    1775 btu/door -22°F (evap temp)
    1625 btu/door -14°F

    NDD5Z - 5 deck dairy/deli
    1550 btu/ft 21°F

    NM4 - 4 deck fresh meat
    1460 btu/ft 11°F
  9. Replies
    56
    Views
    3,933

    FTW! Shut down RTUs and raise head pressure....

    FTW!

    Shut down RTUs and raise head pressure. You will find that pesky leak ;)
  10. Replies
    5
    Views
    461

    Call Carlyle on the screw. Only info I see is on...

    Call Carlyle on the screw. Only info I see is on 5T and 6T screws.
  11. Replies
    6
    Views
    350

    Maybe next year :P Go Packers!

    Maybe next year :P

    Go Packers!
  12. Replies
    5
    Views
    461

    Sure the screws are 4T? For the compound...

    Sure the screws are 4T?

    For the compound comp.:
    06CY = Compound service comp "E" size body
    8 = 30HP
    89 = 89cfm displacement
    J = 575/3/60 voltage
    103 = Single Pack, Service W/O Valves and...
  13. Replies
    10
    Views
    1,118

    Guess we are more aggressive and run a 50 degree...

    Guess we are more aggressive and run a 50 degree DP setting. I prefer a dew point sensor over a RH sensor also. Using a RH sensor, calculated DP has large swings throughout the day.

    Back to OP,...
  14. Replies
    42
    Views
    5,022

    Per my Hussmann rep: Currently, the investment...

    Per my Hussmann rep:

    Currently, the investment group has 60% interest in select manufacturing and sales groups. IR, who holds the other 40% interest, is only invested. They do not have much say in...
  15. Thread: old evap coil

    by MeĞiC
    Replies
    6
    Views
    789

    What is the evap for, cooler or freezer? Box size?

    What is the evap for, cooler or freezer? Box size?
  16. Thread: Hot Shot

    by MeĞiC
    Replies
    13
    Views
    6,254

    That rep and my Copeland rep are on two different...

    That rep and my Copeland rep are on two different pages. My rep insisted using Hot Shot would void any warranty.
  17. Replies
    13
    Views
    1,374

    +1 for the Appion G5

    +1 for the Appion G5
  18. Thread: Hussmann

    by MeĞiC
    Replies
    37
    Views
    5,198

    Press release:...

    Press release:
    http://finance.yahoo.com/news/Clayton-Dubilier-Rice-to-prnews-969972072.html?x=0
  19. Thread: Hussmann

    by MeĞiC
    Replies
    37
    Views
    5,198

    Just got word. Ingersoll Rand has entered into an...

    Just got word. Ingersoll Rand has entered into an agreement to sell a majority share of the Hussmann busniess to funds managed by Clayton, Dubilier, and Rice, LLC (CD&R). Transaction should be...
  20. Replies
    42
    Views
    5,022

    Just got word. Ingersoll Rand has entered into an...

    Just got word. Ingersoll Rand has entered into an agreement to sell a majority share of the Hussmann busniess to funds managed by Clayton, Dubilier, and Rice, LLC (CD&R). Transaction should be...
  21. You'd make more if you "order" the part. Travel...

    You'd make more if you "order" the part. Travel time on the return trip when the part comes in and more time to pull the unit apart again to change the cap.
  22. Thread: PIG ROAST

    by MeĞiC
    Replies
    26
    Views
    5,234

    I grew up down South and they have the best pig...

    I grew up down South and they have the best pig roasts aka "pig pickin'". They use hickory wood to cook. When the pig is done, it gets pulled and chopped. Best part is the cider vinger and red...
  23. Replies
    5
    Views
    1,810

    Anyone use CPC ProAct for monitoring? Good or bad...

    Anyone use CPC ProAct for monitoring? Good or bad comments on them??
  24. Replies
    10
    Views
    1,185

    First I've heard of a GFCI on Hill cases. Sounds...

    First I've heard of a GFCI on Hill cases. Sounds like a broken section of heater wire. Always a pain!
  25. Replies
    42
    Views
    5,022

    I have been told a deal has been reached with an...

    I have been told a deal has been reached with an undisclosed buyer. Lots of rumors as to whom that buyer is. I will not speculate but have good idea.

    It is important because since IR, Hussmann has...
Results 1 to 25 of 114
Page 1 of 5 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event