Search:

Type: Posts; User: Ricky Dale

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. RUNDAWG: I need your wisdom on a Trane actuator motor operation.

    Hello: Forum

    Rundawg, I have a couple questions on the operation of Trane actuator motors installed on a four pipe Trane fan coil unit.
    The actuator motor is...
  2. Replies
    0
    Views
    298

    cycling of fan coil blower motor

    From time to time I work on four pipe Trane fan coil units. They are controlled by Trane's tracer summit software. My question is what cycles the blower motor? The best I can figure is when the space...
  3. Thank you mason

    Thank you mason
  4. Replies
    8
    Views
    611

    The spark module is integrated into the board. ...

    The spark module is integrated into the board. Situation is understood my thanks to mason and a big thanks to rundawg.
  5. Order of safety checks Trane package gas.

    I've gotten conflicting information concerning the order in which the roll out and limit switch are checked to be closed when the there is a call for heat. one person stated the pressure, roll out...
  6. Replies
    8
    Views
    611

    Right you just jarred my brain safetys are...

    Right you just jarred my brain safetys are checked first. Thanks the ignition board is bad. I appreciate you.
  7. Replies
    8
    Views
    611

    My mistake yes the limit switch location. Once I...

    My mistake yes the limit switch location. Once I can confirm the limit switch location and that it is closed i'll know if the ignition board is faulty. The connection are made from the ignitor...
  8. Replies
    8
    Views
    611

    L

    L
  9. Replies
    8
    Views
    611

    L

    L
  10. Replies
    0
    Views
    245

    Trane XL 1600 package gas.

    I have a Trane XL 1600 to look at Monday. So far I've gotten the tech. on the job to confirm the inducer motor runs then the pressure switch closes and that's there is ctrl. voltage between w1 and...
  11. Replies
    8
    Views
    611

    limit rollout switch

    Hello: I have a call to go to on a Trane XL 1600 package gas. I'm short on time with this and would like to know exactly where the limit rollout switch is located. So far I've been told the inducer...
  12. Replies
    75
    Views
    43,668

    Sticky: I didn't ask if it was rocket science i asked...

    I didn't ask if it was rocket science i asked wher is the additions tab.
  13. Replies
    75
    Views
    43,668

    Sticky: additions tab

    where do i find the additions TAB?
  14. Replies
    75
    Views
    43,668

    Sticky: I am so glad to see that members must conduct...

    I am so glad to see that members must conduct themselves verbally as professionals. Thank you very much hvac-talk.
  15. Replies
    35
    Views
    4,107

    answers for heat pum question in Pa.

    A heat pump isn't recommended for you all up there unless it has a new 16 seer plus rating. You all get to cold of weather. make sure no water can drip on your coils and make sure you have drains...
  16. Replies
    18
    Views
    6,665

    suggestion to intermitting defrost problem

    Your defrost board may have an issue which hasn't totally failed.
  17. Replies
    15
    Views
    1,234

    Your sister should have a 5 ton unit. If the...

    Your sister should have a 5 ton unit. If the service man charged me $ for a service call and to add refrigrant, i would tell him to reclaim it and put the $ towards a new unit.
  18. Replies
    10
    Views
    2,595

    This split unit is on top of a high school and...

    This split unit is on top of a high school and the personnel before me i know didn't clean any RTU coils. First stage works fine in heat as well as cool mode. Second stage will frost over on both...
  19. Replies
    10
    Views
    2,595

    I have a 2 stage, 4 compressor Trane split water...

    I have a 2 stage, 4 compressor Trane split water source heat pump that has a problem in the 2nd stage. My liquid line is frosting on both sides of my filter/dryer. I've changed the power head. The...
  20. Replies
    102
    Views
    15,405

    Happy new year! I appreciate the assistance you...

    Happy new year! I appreciate the assistance you all have given me in 09 and look forward to being a more knowledgeable therefore better technician by you alls help this year. Ricky Dale.
  21. Replies
    102
    Views
    15,405

    aren't complimented enough.

    aren't complimented enough.
  22. Replies
    102
    Views
    15,405

    Mr: jpsmith: Thank you i agree totally. People...

    Mr: jpsmith: Thank you i agree totally. People who speak in a negative tone are not happy people and create a negative environment. I personally think they are complimented enough by people...
  23. Replies
    102
    Views
    15,405

    I've bent the ears on a ballists 90 degrees when...

    I've bent the ears on a ballists 90 degrees when 208 joilted me. I don't want any more than that. I've been working around 477 volts for years and never been hit. I respect it very much. We have...
  24. Replies
    102
    Views
    15,405

    Thanks

    Yes you have
    Thank you
  25. Replies
    102
    Views
    15,405

    I work in the field m-f 6:30 to 3 pm. I also have...

    I work in the field m-f 6:30 to 3 pm. I also have my own licensed business. I keep a a800 plus high school operating and well as changing out household units and troubleshooting them. Also some duct...
  26. Replies
    102
    Views
    15,405

    I applied for pro status. I'm hvac certified,...

    I applied for pro status. I'm hvac certified, universal epa certified and will be gas certified on november 21st. We all have questions from time to time i'm just not embarrassed to ask what i need...
  27. Replies
    102
    Views
    15,405

    everything is cool guys. I'm licensed and i'm...

    everything is cool guys. I'm licensed and i'm taking my gas license test next month in gulf shores alabama. I also have my universal epa certification. May i add i'm also a certified computer...
  28. Replies
    102
    Views
    15,405

    research

    I do online rearch and am currently studing for my gas license which i will also have this month. I usuall work on single pahse and am certantly still learning. Thanks
  29. Replies
    102
    Views
    15,405

    compressors

    Ok i got it ; like i thought but always verify. I work on a lot of different water source heat pumps and also split heat pumps, dual fuel rtu's 20 tons and larger. Sometimes i get in a little of a...
  30. Replies
    102
    Views
    15,405

    info

    Thanks
  31. Replies
    102
    Views
    15,405

    New post need to ask simple questions and confirm...

    New post need to ask simple questions and confirm therories. professional well attituded people in converstation. So i would personality take an ohm reading from the l1 l2 and l3 to ground and put my...
  32. Replies
    102
    Views
    15,405

    getting the posting in to ask useful questions,...

    getting the posting in to ask useful questions, what's wrong with that?
  33. Replies
    102
    Views
    15,405

    What will my fieldpiece display when i'm checking...

    What will my fieldpiece display when i'm checking for a grounded winding to the housing if the compressor is bad?
  34. Replies
    102
    Views
    15,405

    What should the ohm reading display on my...

    What should the ohm reading display on my fieldpiece meter when the l1 l2 or l3 lines are bad?
  35. Replies
    102
    Views
    15,405

    Do i check the l1 l2 and l3 lines in for...

    Do i check the l1 l2 and l3 lines in for infinity on my ohm meter? Do i listen for a tone?
  36. Replies
    102
    Views
    15,405

    The line in l1 l2 l3 must be checked with a...

    The line in l1 l2 l3 must be checked with a megger for current draw and be within range?
  37. Replies
    102
    Views
    15,405

    attitude

    Attitude is everything and most of you all's aren't professional or welcoming. try to feel better and you will respond in a positive light.
  38. Replies
    102
    Views
    15,405

    compressor troubleshooting

    Thanks i suspected that the rod was loose from the piston slapping around, but really what is the best way to check for a a three phase compressor hat shorted to ground or has an opening winding ? I...
  39. Replies
    102
    Views
    15,405

    wasn't thinking work on all phases

    I know three phase are L1, l2, l3 with the same voltages to each. The compressor sounds like the rod came loose from the pistion if you know what i mean. I just want to prove it bad. By doing an amp...
  40. Replies
    10
    Views
    1,062

    restriction

    Thank you, i'm really very bright just new to the commerical side. Not use to members/people with such bad attitudes and dispositions. We have southern hospitality here it must not exists in some...
  41. Replies
    10
    Views
    1,062

    Thank you all

    Thank you all
  42. Replies
    102
    Views
    15,405

    professional attitude

    Thanks your attitude is good i'm still learning and am doing well. yes their are a lot of people here who must believe they were born knowing what they do today. I'll see how many amps it drawing and...
  43. Replies
    10
    Views
    1,062

    metering problem/restriction

    Hi: I have a unit that is frosting the feeder tubes to the evaporator and then thraws. I continue to have a restriction after i've replaced the power head. My low side is 50 psig it will not allow me...
  44. Replies
    102
    Views
    15,405

    3 phase compressor check

    Hi : How would i check a three phase operated compressor and prove it bad?Check each terminal s, r &c to the housing for a tone or high ohm reading? Thanks Rick.
  45. Thank you

    Thank you
  46. powerhead installation on trane heat pump

    I'm new at working on commerical systems. I have a good general idea about installing a power head on a txv. I believe i need to recover the refrigiant, take off the old head and bulb and install the...
Results 1 to 46 of 183
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event