Search:

Type: Posts; User: The Reaper

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    3
    Views
    252

    I have replaced the old MicroLite panels with the...

    I have replaced the old MicroLite panels with the Triatek lighting panels. I did an upgrade of an old NCM-200 and the MicroLite's wouldn't work. They are a proprietary N2. The Triatek's were very...
  2. Replies
    1
    Views
    300

    Barber Coleman Micro Net Room Sensor

    I got a call today for a Micro Net space sensor display being blank. I removed the sensor and metered it. There was no DC voltage. I traced the wire back and found it wired to the comm bus?? Has...
  3. I just use a B&B 232 to 485 convertor right to...

    I just use a B&B 232 to 485 convertor right to the ASD bus. Works every time.
  4. Replies
    2
    Views
    200

    You will need a licensed copy of Honeywell...

    You will need a licensed copy of Honeywell Workbench and the proper Spyder tool. Are these things stand alone or are they wired into a Jace?
  5. Replies
    6
    Views
    1,702

    Sorry! Just saw the date on this! Talk about...

    Sorry! Just saw the date on this! Talk about digging up an old thread!
  6. Replies
    6
    Views
    1,702

    Where in the Northeast are you? I have one in my...

    Where in the Northeast are you? I have one in my bag of tricks. I'm in CT.
  7. Replies
    6
    Views
    366

    Thanks for all the replies. This is for a VAV...

    Thanks for all the replies. This is for a VAV system with hot water reheats. I think ASHRE has something out there about this. I'll do some more digging.
  8. Replies
    6
    Views
    366

    Percentage Of Performance

    I have a customer that wants to calculate a percentage of system performance on individual heating zones. I am at a loss as to how to do this. Has anybody done something similar? TIA.
  9. Replies
    3
    Views
    585

    NAE Point Summary

    I'm upgrading some older NAE's to FX and I was wondering if there was a way to get a summary of all the points in the system with their mappings? This place has a lot of DX's and nobody left the tag...
  10. Replies
    1
    Views
    243

    I figured it out. I needed to put the file name I...

    I figured it out. I needed to put the file name I was transferring on the destination as well.
  11. Replies
    1
    Views
    243

    American AutoMatrix Sage Question

    I'm trying to use the Sage to copy a .plb out of a controller. I go to utilities, remote copy and set all the port/peer info and I keep getting an access denied error. Any ideas? Thanks in advance.
  12. Replies
    6
    Views
    1,705

    Email sent.

    Email sent.
  13. Replies
    1
    Views
    268

    Disregard. Blonde moment is resolved. I forgot...

    Disregard. Blonde moment is resolved. I forgot that you can use a switch with analog and boolean values.
  14. Replies
    1
    Views
    268

    Alerton BACtalk Programming

    I'm having a blonde moment! I'm trying to use a BV in the BTI to hit a bunch of BV's in different controllers. When the global BV is true, I need to write a false and when the global BV is false, I...
  15. Give this a try. I've had to do this a couple of...

    Give this a try. I've had to do this a couple of times.
  16. Replies
    3
    Views
    406

    Thanks alot Cagey!!

    Thanks alot Cagey!!
  17. Replies
    3
    Views
    406

    AX User Name = 2000:00

    I see the time changing in an FX70 and it logs the change under the user name 2000:00. Anybody know what that means? TIA
  18. Replies
    2
    Views
    337

    I think you're going to have to run it in a VM....

    I think you're going to have to run it in a VM. I'm pretty sure it's not compatible with Windows 8. The cheapest adapter I found is a B&B 232/485 convertor. They are less that 100 bucks and can be...
  19. Replies
    1
    Views
    312

    AutoMatrix Emailing Alarms

    I just took over a site with 8 SageMax controllers and an AutoPilot/WebPilot front end. The customer would like to receive alarms via email. Can this be done? I haven't worked on AutoMatrix since the...
  20. Replies
    1
    Views
    383

    Station Tunnelling

    I have a customer that has 6 Jaces and a supervisor. The supervisor IP isn't exposed to the outside world, but the first Jace ( pre supervisor ) is. Can I use the exposed Jace to tunnel to another...
  21. Replies
    1
    Views
    330

    I found out that I need a USB to SD convertor to...

    I found out that I need a USB to SD convertor to properly back these up. Does anybody know the proper size SD card? I remember that older operating systems such as these will not recognize anything...
  22. Thread: AAM GC1

    by The Reaper
    Replies
    1
    Views
    260

    Here is the GC manual. You are going to need a...

    Here is the GC manual. You are going to need a copy of SoloPro and a 232/485 converter to do anything with this controller. If there is a Sage onsite, you can do everything through that. If you can...
  23. Replies
    9
    Views
    513

    Thanks for the replies. The customer wants this...

    Thanks for the replies. The customer wants this live on his graphics continually displaying usage in his central plant. This is Workbench 3.8.38.
  24. Johnson Controls does have a BACnet TEC that does...

    Johnson Controls does have a BACnet TEC that does this. The part number is TEC2613-4.
  25. Replies
    9
    Views
    513

    AX History Pie Chart

    I had a customer ask me if I could display several central plant Kw's in a pie chart on a px. Any idea if this is possible? Thanks in advance.
  26. Replies
    1
    Views
    330

    AAM Sage Backup

    I just took over a large AutoMatrix system with 7 Sages. I went to back them up with a box of floppy disks and 2 of the Sages had USB ports only. I figured out that it was seen as B drive, but...
  27. Replies
    10
    Views
    2,374

    Acronis has a universal restore feature that I...

    Acronis has a universal restore feature that I have used before with different hardware . It saved me a lot of headaches.
  28. Replies
    10
    Views
    2,374

    Check out a program called Acronis. It makes a...

    Check out a program called Acronis. It makes a mirror image of any machine and restores it to any other machine. Very easy to use.
  29. Replies
    6
    Views
    726

    The pass through is a component that allows you...

    The pass through is a component that allows you to use the NAE as a router to upload/download controllers. It needs to be installed separately on any machine that you will be using for this purpose.
  30. Check out Flexim. They are pricey but good. I...

    Check out Flexim. They are pricey but good. I just put a dual channel ultrasonic BTU meter on a chilled water loop and it is awesome! You can get all data via Modbus out of the meter.
  31. Replies
    2
    Views
    511

    That was it. Thanks!

    That was it. Thanks!
  32. Replies
    2
    Views
    511

    RTD Question

    I have an RTD that I need to reuse on an AHU. This reads the discharge temp on a gas burner. There is no part number in it. There is some info on the sensor that says RTD CO 1000 ohms @ 0 C 79457-1....
  33. Replies
    32
    Views
    5,029

    That wouldn't be in a public school in northern...

    That wouldn't be in a public school in northern Connecticut would it?
  34. Replies
    2
    Views
    419

    Sorry for the delayed response. That was it....

    Sorry for the delayed response. That was it. Thanks for the help!
  35. Replies
    2
    Views
    419

    Ax BACnet Export Write Fail

    I have a customer that is putting some demand based energy software into his facility and he wants to use it to command points in the Jace via BACnet IP. He can see all of my points and I have all...
  36. Replies
    0
    Views
    217

    Flexim AMD-7407 Modbus Integration

    Trying to figure out the registers on a Flexim AMD-7407 BTU meter. The factory was no help at all. Has anybody integrated to these before? Thanks in advance.
  37. Thanks

    Thanks
  38. You are correct. This is a Contemporary Controls...

    You are correct. This is a Contemporary Controls router. The problem is, I can't get it to scan into my device manager. I made sure I can get into the config through a browser, so I know the IP side...
  39. Alerton BACtalk Programming with IP to mstp Router

    Does anybody know if you can set up an IP to mstp router to be able to upload/download BACtalk controllers through Envision for BACtalk? I'm running a copy on my laptop with a valid key and I can't...
  40. Replies
    8
    Views
    529

    Sent you an email.

    Sent you an email.
  41. Replies
    8
    Views
    529

    I found the 1.8 disks. Is it on the auxiliary...

    I found the 1.8 disks. Is it on the auxiliary disk? What is the name of the program? Never throw anything away!!
  42. Replies
    8
    Views
    929

    You've got mail.

    You've got mail.
  43. Replies
    7
    Views
    660

    Got it! Thank You!

    Got it! Thank You!
  44. Replies
    8
    Views
    529

    I have a set of 1.8 utility disks somewhere in my...

    I have a set of 1.8 utility disks somewhere in my many piles of crapola. I'll look around and if I find it, I'll post it.
  45. Replies
    7
    Views
    660

    Thanks for the response. I like the way you...

    Thanks for the response. I like the way you think! Always striving to do things better. I'd like to see an example of the program object if possible. If not, I totally understand. I've been trying to...
  46. Replies
    7
    Views
    660

    BQL Information

    Does anybody have some good information on setting up BQL summaries? Thanks in advance.
  47. Replies
    8
    Views
    929

    Do you have access to the JCI FX site? One of the...

    Do you have access to the JCI FX site? One of the JCI FX guys posted a PWM module.
  48. Replies
    1
    Views
    352

    Never mind. Figured it out.

    Never mind. Figured it out.
  49. Replies
    1
    Views
    352

    Metasys GGT Question

    I have a customer that would like me to change all of the room names on the graphics and in the tree structure of the NAE's. How do I re bind the points in the GGT? I think they are using aliases....
  50. Replies
    1
    Views
    260

    Carrier Aquasnap BACnet Communications

    Does anybody have a list of BACnet points available for a 180 ton Aquasnap? I need to know what is writeable. Thanks in advance.
Results 1 to 50 of 957
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech365 Virtual Event