Search:

Type: Posts; User: yotaman16

Page 1 of 16 1 2 3 4

Search: Search took 0.05 seconds.

  1. Replies
    3
    Views
    305

    The only thing it will let me change is the temp...

    The only thing it will let me change is the temp set point. I need to change deforst max time and termination temp. It just beeps. That's is the manual I as looking at.
  2. Replies
    3
    Views
    305

    Avantco / ascend controler

    Hey guys I just replaced a controler sf104 but I'm in able to change any settings other then the temp . Any ideas? The manual I found said hold on the down arrow for 10 seconds. I get no response
  3. Replies
    1
    Views
    242

    York drain pan part number

    Was wondering If anyone out there would have a part number for a York evap drain pan. Here's the kicker it's old no model or serial anywhere. It's a 6 ton sun line with the old tandem Bristol...
  4. Thread: Pipe size

    by yotaman16
    Replies
    9
    Views
    513

    I forgot it's r22

    I forgot it's r22
  5. Thread: Pipe size

    by yotaman16
    Replies
    9
    Views
    513

    Pipe size

    Hey guys I need to move a walkin cooler condensing unit. There are two 28000 btu evaps tied together with 7/8 then run to the condensing unit with 1 1/8. The liquid line is 1/2. The condensing unit...
  6. Replies
    6
    Views
    956

    That was my thought also. It's a strange icing...

    That was my thought also. It's a strange icing problem. I'm heading to the site now to check the superheated now that the box is at temp and we shall know for sure
  7. Replies
    6
    Views
    956

    Walk in cooler icing problem

    Gita call on Thursday cooler iced up. The customer shut the condensing unit down to deice evap coil. I arrived on site to find some ice in the center of the coil along with several paper towels...
  8. Replies
    36
    Views
    3,457

    Did ou make sure the drain is trapped

    Did ou make sure the drain is trapped
  9. Thread: Gas train

    by yotaman16
    Replies
    5
    Views
    712

    Can't find any parts is my issue no one knows...

    Can't find any parts is my issue no one knows what this is
  10. Thread: Gas train

    by yotaman16
    Replies
    5
    Views
    712

    Yep they were useless. They said hey don't keep...

    Yep they were useless. They said hey don't keep info of units older then 5 years.. Great service on there part
  11. Thread: Gas train

    by yotaman16
    Replies
    5
    Views
    712

    Gas train

    Hey guys ran into a unit with a gas train in not familiar with. The first blocking valveis leaking at the solenoid. I either nerd to replace the valve or repair. I have no clue where to start and...
  12. Replies
    15
    Views
    2,262

    I dont see any sensing bulb.. To me looks like a...

    I dont see any sensing bulb.. To me looks like a fan control on a furnace
  13. Replies
    7
    Views
    2,305

    The set up thats there is so far gone it all...

    The set up thats there is so far gone it all needs to go and start from scratch
  14. Replies
    16
    Views
    2,816

    Which capacitor is that next to the flux...

    Which capacitor is that next to the flux capacitor, run capacitor or start capacitor? Im having trouble locating it !!!!!
  15. Replies
    7
    Views
    2,305

    The hood is way to small, the exhaust fan is...

    The hood is way to small, the exhaust fan is undersized and there's no make up air
  16. Replies
    7
    Views
    2,305

    Kitchen exhaust hood install

    Hey guys never done a total install on a hood. Usually just service and replace equipment as needed. I have a account that needs everything new due to the addition of new equipment. The hood has just...
  17. i went last nov. and it was great.. i did the csr...

    i went last nov. and it was great.. i did the csr class
  18. Thread: Manitowoc

    by yotaman16
    Replies
    15
    Views
    1,730

    im with ice on this.. also check the weep holes...

    im with ice on this.. also check the weep holes on the plate.. those hpr system are tricky if your not fimilar..

    Yes if you call tech support they speak english there located in Mainitowoc...
  19. Replies
    13
    Views
    1,411

    X2

    X2
  20. Replies
    13
    Views
    2,132

    Thats what i do i use the 3lb and hit a block of...

    Thats what i do i use the 3lb and hit a block of wood so i dont dent the pan then pull it out in pieces and melt the rest
  21. Replies
    68
    Views
    8,869

    Had a similar case do this to a tech at my old...

    Had a similar case do this to a tech at my old company.. Did exactly what you did and nothing..If i were you before you do anything i would do a performance curve. but i would ave the tx and nozzle...
  22. Replies
    11
    Views
    1,255

    We had had a bunch of problems with Sporland...

    We had had a bunch of problems with Sporland solenoid valves not closing.. My company wont install them any more after like the 3rd one in a year. One of those was A flare valve too
  23. Replies
    18
    Views
    1,883

    h10 is the best but...... The newer ones seem to...

    h10 is the best but...... The newer ones seem to be pickey.. I wish i had one that was 10 years old
  24. Replies
    18
    Views
    2,039

    from the looks that trane has long done its duty...

    from the looks that trane has long done its duty and that things gotta make noise in the building
  25. Thread: etc

    by yotaman16
    Replies
    8
    Views
    844

    I like the ETCs as was stated.. I refuse to use...

    I like the ETCs as was stated.. I refuse to use any of the multi stats.. We have had way to many problems with them, jc mr4, the sporland, dixle they dont seem to last..
  26. Thread: torch set

    by yotaman16
    Replies
    1
    Views
    800

    torch set

    hey guys im in the market for a new oxy-acy torch kit.. i currently run the smith quick braze kit but they dont make the good tip any more and was looking for a new setup.. I do all commercial...
  27. Replies
    10
    Views
    1,807

    IRON OUT .. dont say i said so tho.. will make...

    IRON OUT .. dont say i said so tho.. will make the machine look new in no time.. Im not sure as i would use try it on the nickel evap plate.. When i was out at the mani factory this year they...
  28. Thread: classes

    by yotaman16
    Replies
    5
    Views
    484

    classes

    Hey guys my company wanted me to take a gas class so i can run some calls out of state.. Should i be getting paid for this class thats 50 hrs long?
  29. Replies
    17
    Views
    7,616

    I charge both high and low depending on how much...

    I charge both high and low depending on how much gas. then let it sit but usually only 5-10 mins
  30. Replies
    21
    Views
    1,562

    i went 2 years ago it was good class and a hell...

    i went 2 years ago it was good class and a hell of a time haha
  31. Replies
    13
    Views
    1,921

    i like the way u think.. but that could make it...

    i like the way u think.. but that could make it more of a pain to change the dryer depending on the location of the glass..
  32. Replies
    17
    Views
    1,949

    what defrost clock is in the unit so we can start...

    what defrost clock is in the unit so we can start with a diagram for that becuase thats your first problem then u will be able to further troubleshoot the system
  33. Replies
    17
    Views
    1,949

    what exactly are u looking for info on?

    what exactly are u looking for info on?
  34. Thread: veto bag

    by yotaman16
    Replies
    76
    Views
    8,114

    Im probibly the cheepest person i know and it...

    Im probibly the cheepest person i know and it KILLED me to finally break down and spend 140 on the veto pro XL.. But the bag is awesome, plenty of room for all my junk, Its very sturdy and well worth...
  35. Thread: Super Seal

    by yotaman16
    Replies
    10
    Views
    1,202

    cap tube and tx valve plug in a can.. people r...

    cap tube and tx valve plug in a can.. people r just to lazy to find and fix the leak
  36. Replies
    7
    Views
    1,167

    would have to agree some of the danfoss tx in...

    would have to agree some of the danfoss tx in manitowoc machine MUST be mounted in a certain position.. But most it doesnt matter
  37. Replies
    23
    Views
    2,377

    like they said , front seat the reciever king...

    like they said , front seat the reciever king valve and see if it pumps down. If not do a performace curve or cheat if you have a suction service valve and front seat that and run the compressor into...
  38. Replies
    11
    Views
    905

    2 years sounds right, i have the same issue but...

    2 years sounds right, i have the same issue but they keep taking out the ignition every year ...
  39. Replies
    10
    Views
    1,109

    i install the ranco etc. Ive only seen one fail...

    i install the ranco etc. Ive only seen one fail and ive installed over 100 of them, but seen 2 of the 419s go bad
  40. Replies
    22
    Views
    4,139

    weird i had this happen about 2 months ago my...

    weird i had this happen about 2 months ago my self. We had a tech install a new solenoid valve sporland 3/8 sweat with extended connections and manual open stem on it. Next day evap all iced up and...
  41. Replies
    29
    Views
    2,542

    Your pumping this unit down and theres no...

    Your pumping this unit down and theres no reciever tank?
  42. Replies
    29
    Views
    1,666

    I would think that the walls of the walk in box...

    I would think that the walls of the walk in box would take a ton of moisture in seeing its gonna be 100% humidity. Unless u totally seal off everything with that said epoxy or something
  43. Replies
    10
    Views
    752

    2-3 psi is probibly taking your gages on and...

    2-3 psi is probibly taking your gages on and off.. llsv on a reach in?
  44. Thread: manitowoc

    by yotaman16
    Replies
    23
    Views
    1,610

    how would u even go about charging a critical...

    how would u even go about charging a critical charged system when theres still gas in it ??
  45. Replies
    7
    Views
    1,397

    i run mine till i get a good feeling about it and...

    i run mine till i get a good feeling about it and hear the pump.. who needs a micron gage anyways haha
  46. Replies
    4
    Views
    557

    just did this on a victory took about 4 from time...

    just did this on a victory took about 4 from time i got there till i was done. But it was a diffrent model.. some go easy some hard.. I love the units with the evap on the top in a seprate box like...
  47. Replies
    17
    Views
    1,202

    same here NEVER seen a leaking ranco

    same here NEVER seen a leaking ranco
  48. Replies
    11
    Views
    2,668

    i seen a guy charging his ac in his van with 409...

    i seen a guy charging his ac in his van with 409 last month lol
  49. Replies
    115
    Views
    19,145

    He might be doing thatt to get the head pressure...

    He might be doing thatt to get the head pressure up to clear the glass... I have a few systems that, is the charging procedure for those walk-ins. Makes no sense to me to raise the head then clear...
  50. Replies
    4
    Views
    605

    because theres little to no gas flowing through...

    because theres little to no gas flowing through the coil so what heat is that is there is getting added to less gas then normal
Results 1 to 50 of 792
Page 1 of 16 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event