  1. Replies
    3
    Views
    299

    Nest and variable speed

    We installed three Trane 16i 2 speed systems and the owner of the new home owner provided us with the Nest thermostats he wanted to use and they have been running good but we had one system start...
  2. Replies
    11
    Views
    505

    Yes I knew the mini port was text only but he...

    Yes I knew the mini port was text only but he wanted to see if the ip address that is labeled on the panel was correct. We have the ip listed but still it wont connect, am wandering if the windows 7...
  3. Replies
    11
    Views
    505

    Okay, new delimma, I`ve gotten several different...

    Okay, new delimma, I`ve gotten several different connectors. We have tried the usb to 9 pin to rj12 cable to the summit board and it would not connect. Then a friend said he uses an ethernet cable...
  4. Replies
    11
    Views
    505

    Thanks very much guy`s that puts me in the right...

    Thanks very much guy`s that puts me in the right direction so i`ll see what I can come up with.
  5. Replies
    11
    Views
    505

    I was told that windows 7 took a different usb...

    I was told that windows 7 took a different usb connecter butt my contact is out of town and no oneelse seems to know that. Even a computer guy told me that different items you are trying to connect ...
  6. Replies
    3
    Views
    255

    Clunks in the outdoor unit could be animals...

    Clunks in the outdoor unit could be animals getting into the fan blades or you could have some hard starting issues in the fan or compressor.
    Best to have a tech come out and service the equipment...
  7. Replies
    11
    Views
    505

    Tracer Summit connection

    Hi guy`s, just a quick question: can someone tell me the proper USB connection I need to connect our laptop with windows 7 installed so we can access the summit system. I have the 9 pin to RJ12...
  8. Replies
    2
    Views
    339

    In a typical system set up you would have an air...

    In a typical system set up you would have an air handler which would sit on top of a plateform which would be sealed with a return air grille that allows the air to inter the system and your fiter...
  9. Replies
    5
    Views
    431

    Honeywell PRO 6000 is battery operated and...

    Honeywell PRO 6000 is battery operated and programmable. You have an installers guide that you will have to be able to understand what type system you have and how to configure it to operate your...
  10. Thread: Brand???

    by mlc1955
    Replies
    7
    Views
    733

    is luxaire v/s model # for the blower. To get...

    is luxaire v/s model # for the blower. To get tonnage you need to get the model # of the coil that is installed.
  11. Replies
    2
    Views
    304

    Sounds like there may be freon issues, will need...

    Sounds like there may be freon issues, will need to have system serviced.
  12. You are not styck with the contractor, even if...

    You are not styck with the contractor, even if you have a 10 year parts and labor warranty you can still use another Trane deater for warranty issues. And I also am well pleased with the reliability...
  13. Replies
    10
    Views
    566

    What mode of operation are you asking for, cool...

    What mode of operation are you asking for, cool or heat and are these heat pump systems. If you are asking for the system to cool in the cooler weather this could drive the suction pressure down...
  14. Replies
    7
    Views
    444

    Whatever beand you use if you are concerned about...

    Whatever beand you use if you are concerned about power consumption then the higher the SEER rating the les the power useage. Bear in mind the higher the SEER rating the higher the cost. Stick to...
  15. You said the thermostat was on emergency heat...

    You said the thermostat was on emergency heat which will also prevent the outdoor unit from coming on. It should be in the heat mode to operate properly, the auxilary heat may not be big enough to...
  16. Replies
    1,144
    Views
    111,586

    Sticky: Good to have you guys here. We all need advise...

    Good to have you guys here. We all need advise from time to time so ask away and hope you can help us to.
  17. Replies
    15
    Views
    1,015

    I agree on looks like a crack. Normally heat...

    I agree on looks like a crack. Normally heat exchangers last quiet awhile but who s willing to take the chance of not waking up tomorrow?
  18. #1, If you have a 2 speed system you should...

    #1, If you have a 2 speed system you should alresdy have a variable speed blower but that doesnt mean it will speed up or slow down to match how many zones are calling. It only means it will match...
  19. I am not familiar with the crestron stat but the...

    I am not familiar with the crestron stat but the xl20 is a communicating system so the stat has to be communicating and im sure you would want that to be a matching communicating stat for proper...
  20. Replies
    3
    Views
    386

    Do you have a serial #

    Do you have a serial #
  21. I`m not a big fan of zoneing, but if I were to do...

    I`m not a big fan of zoneing, but if I were to do that and had plenty of room to get the dampers and extra return air from basement in I beleive i would go with 2 stage equipment so that I could set...
  22. Thread: ok what is it?

    by mlc1955
    Replies
    17
    Views
    1,055

    I think I would rule out low airflow across the...

    I think I would rule out low airflow across the indoor coil because if that was driving the high up usually the suction would go up also. Generally a refrigerant flow restriction makes the head go go...
  23. Replies
    3
    Views
    780

    Your 16 seer is a 2 step system which means at...

    Your 16 seer is a 2 step system which means at 1st call you have about 80% capacity come on and fan speed should level out at same. if it gets the second call it will speed up to full capacity and...
  24. Thread: New Heat Pump

    by mlc1955
    Replies
    6
    Views
    391

    I agree they will all work but there are...

    I agree they will all work but there are diferences in the units so do some homework. some are more noisy than others and some are put together better. Carrier, Lennox better than the others....
  25. Replies
    3
    Views
    778

    Agreed! you need to utillize the extra btus from...

    Agreed! you need to utillize the extra btus from that unit. You can install a mortorized damper and thermostat in that area but it would only open and close the damper and not control the system on...