  1. well right now I just want to replace the outdoor...

    well right now I just want to replace the outdoor unit but is r22 and all the contractors iv spoke with are hell bent on selling a package unit and tying into the existing duct work.
  2. single

    single
  3. yes the duct is 4 x12" x 70 feet long. what do...

    yes the duct is 4 x12" x 70 feet long. what do you mean by return ducting? I clean the A coil filters once a month even if they don't need it.

    the duct is in r19 insulation in the floor joist...
  4. time to replace a/c condenser advice please

    So I live in a mobile home and I hate it. its so hard to keep cool in the summer when its 95+ F and with 80+ humidity yep south GA. The ac struggles to keep below 80 F by 3:00 pm and will use window...
  5. Replies
    15
    Views
    1,335

    I live in south GA the ac runs all year long even...

    I live in south GA the ac runs all year long even in the winter and it cant keep up in the hot humid summer months so i have to run 2 8,000 btu window ac units. So it takes 4.5 tons of cooling to...
  6. Replies
    15
    Views
    1,335

    Its fine now the yellow wire didn't connect to...

    Its fine now the yellow wire didn't connect to anything. The cap was reading 9 so i replaced it too. It runs much smother now.

    one other thing if i decide to replace my outside unit that's 13...
  7. Replies
    15
    Views
    1,335

    Hey i pulled the blower motor out it was hard to...

    Hey i pulled the blower motor out it was hard to turn the shaft so im in the process of replacing the motor but there is only 6 wires on the new motor and the old one had 7.

    black to Hi
    blue to...
  8. Update i tested the sequencer and it was bad...

    Update i tested the sequencer and it was bad replaced it and fixed the problem.
  9. Replies
    15
    Views
    1,335

    the label is very hard to read the diagram on the...

    the label is very hard to read the diagram on the panel i cant see it. Does any one have a diagram.
  10. Replies
    15
    Views
    1,335

    Suction line icing up

    The central Fan unit is shutting off but the outside unit keeps on running till the line freezes. The central fan does work for about a minute befour it shuts off after the thermostat is reset.

    I...
  11. I did but cant run the a/c now. Everyone is...

    I did but cant run the a/c now. Everyone is closed around my area.
  12. NORDYNE heater elements glowing red hot when thermostat set to off.

    Nordyne E2EB-015HA elements are coming on when the thermostat is set to off or even set to A/C. It glows red hot for a few seconds then the limit switch kicks it off, then on again and so on.
    I...
  13. Replies
    7
    Views
    1,062

    i found a leak. its the small suction line that...

    i found a leak. its the small suction line that connects to the indoor evap. i tried to tighten it down with line wrenches but it started leaking even more so i backed down and the leak slowed down....
  14. Replies
    7
    Views
    1,062

    there are no flashing green lights.

    there are no flashing green lights.
  15. Replies
    7
    Views
    1,062

    the temp coming out of the indoor unit is 80F...

    the temp coming out of the indoor unit is 80F when the condenser is running.
  16. Replies
    7
    Views
    1,062

    mini split cutting off and on

    i have 14k mr. slim and it keeps cutting off and on. it stays on for 5 mins and than back on for 5 mins. is this normal? also the condenser fan speed starts out slow and picks up to high speed...