Search:
Type: Posts; User: hobbit
Search: Search took 0.01 seconds.
-
03-24-2013, 08:52 AM
Thread: Heating airflow theory Q
by hobbit- Replies
- 7
- Views
- 587
Thanks for the responses so far! The end goal,...
Thanks for the responses so far! The end goal, really, is simply
determining whether to run my HP system on high fan or low fan
in heating mode, and have broader perspective on the advantages
or... -
03-21-2013, 11:05 AM
Thread: Heating airflow theory Q
by hobbit- Replies
- 7
- Views
- 587
Heating airflow theory Q
In the tradition of my little headscratchers which are either
thought-provoking or totally stupid, I'm not sure which, here's
another theory question. This would be a purely heating scenario,... -
Wet duct
Hopefully this doesn't tread too far toward DIY territory, but
I've got a little problem with a cold-air intake that someone
might have some insight into. You guys must deal with
fresh-air inlet... -
01-04-2013, 09:00 AM
Thread: cold weather operation
by hobbit- Replies
- 19
- Views
- 1,579
beenthere, that's awesome; a quick look at a...
beenthere, that's awesome; a quick look at a psych chart makes
it make sense, except that the chart I usually use only goes
down to 20F. Still, clearly not a whole lot of grains to be
had in air... -
01-02-2013, 08:43 AM
Thread: cold weather operation
by hobbit- Replies
- 19
- Views
- 1,579
I'm aware of how the indoor and outdoor coils...
I'm aware of how the indoor and outdoor coils have to swap functions,
and even know exactly where my reversing valve is... what I'm trying to
understand is what happens to subfreezing *air* when it... -
01-01-2013, 01:09 PM
Thread: cold weather operation
by hobbit- Replies
- 19
- Views
- 1,579
cold weather operation
I've got a couple of general questions about heat-pump operation
in cold ambients. One practical, one more theory.
Most units either have a crankcase heater or use the inverter to
bleed about... -
11-07-2012, 03:23 PM
Thread: heat pump fan high or low?
by hobbit- Replies
- 0
- Views
- 293
heat pump fan high or low?
Swinging into heating season here, I'm wondering if it's better
to run a heat pump's AHU blower at a higher or lower speed?
While lower is better for summer dehumidification, if we're only... -
09-21-2012, 06:23 PM
Thread: careless commissioning?
by hobbit- Replies
- 16
- Views
- 1,295
Trust me, the second company will be who gets...
Trust me, the second company will be who gets called next [unless
I have an actual warranty issue] but really, with periodic simple
care/cleaning that I can do myself I'm hoping to not have to call... -
09-21-2012, 05:11 PM
Thread: careless commissioning?
by hobbit- Replies
- 16
- Views
- 1,295
I don't know if it's better to follow up on a...
I don't know if it's better to follow up on a really old thread
or start a new one; I'll try it this way first.
I finally had another service company come out and eyeball my
Daikin setup and... -
09-10-2012, 02:03 PM
Thread: EXV forced closure?
by hobbit- Replies
- 4
- Views
- 303
Yup, the Daikin FTQ type air handler. Quoting...
Yup, the Daikin FTQ type air handler. Quoting from the
install manual description for option block terminals 9,10:
"Receives input: Forced closure of indoor unit Electronic
Expansion Valve during... -
09-10-2012, 10:05 AM
Thread: EXV forced closure?
by hobbit- Replies
- 4
- Views
- 303
EXV forced closure?
I recently noticed that my air handler / indoor coil has a pair
of dry-contact input terminals to force its EXV to CLOSED during
cooling mode.
When/why would you want to do this, and/or why... -
08-07-2012, 06:35 AM
Thread: Daikin: no emergency operation??
by hobbit- Replies
- 0
- Views
- 214
Daikin: no emergency operation??
I've run into what might be the first notable downside of a two-wire
digital 'stat interface, as opposed to the typical W1/W2/Y/G/etc bundle
of wires between a typical stat and an indoor unit. ... -
07-22-2012, 11:56 PM
Thread: when does emergency/backup heat kick in
by hobbit- Replies
- 6
- Views
- 603
That would all likely be true *IF* this rig had a...
That would all likely be true *IF* this rig had a traditional stat.
It doesn't. Daikin's big thing WRT control is two-wire data
links -- one two-wire shot to the stat, and another one from the... -
07-22-2012, 11:10 PM
Thread: another silly psych question
by hobbit- Replies
- 13
- Views
- 1,460
It finally got warm enough again that I was able...
It finally got warm enough again that I was able to get the coil loaded
up and try to take a CFM measurement. The filter slot opening is
about the same dimension as the main return duct, so I pull... -
07-21-2012, 09:24 AM
Thread: when does emergency/backup heat kick in
by hobbit- Replies
- 6
- Views
- 603
I did have that thought ... except that OAT can't...
I did have that thought ... except that OAT can't be measured if the
outdoor unit doesn't have power anyway. The scenario I'm thinking
is indoor AHU powered, outdoor unit dead ... I should still... -
07-21-2012, 07:45 AM
Thread: when does emergency/backup heat kick in
by hobbit- Replies
- 6
- Views
- 603
when does emergency/backup heat kick in
This is kind of a general question and the specifics for particular
brands/units might be all over the place. I'm in New England, where
we have ice storms and weird "snowpocalypse" events and... -
07-21-2012, 07:14 AM
Thread: another silly psych question
by hobbit- Replies
- 13
- Views
- 1,460
That's about what I was thinking, re: COP. The...
That's about what I was thinking, re: COP. The outdoor unit was
drawing all of 3 or 4 amps at 240V, less than a kilowatt for several
hours. This particular experiment went on fairly far into the... -
07-19-2012, 06:06 PM
Thread: another silly psych question
by hobbit- Replies
- 13
- Views
- 1,460
another silly psych question
No, this isn't about my "macguyvered" windowshaker-turned-dehum; that's
been put away for the moment because the real system is doing so much
better at water removal. So I've been studying that a... -
07-10-2012, 11:13 PM
Thread: inverter unit pumpdown
by hobbit- Replies
- 10
- Views
- 950
Sorry, it probably came out a little wrong as can...
Sorry, it probably came out a little wrong as can often happen in
email. And yes, the spam-filters are pretty strict over here, but
the rejection should have indicated something about why it... -
07-07-2012, 10:23 PM
Thread: inverter unit pumpdown
by hobbit- Replies
- 10
- Views
- 950
Hmm. That's one of the issues, finding someone...
Hmm. That's one of the issues, finding someone who is willing to
do all that due diligence. The guy who installed this rig for me
apparently isn't.
It probably seems like I'm going too hard on... -
07-07-2012, 03:26 PM
Thread: inverter unit pumpdown
by hobbit- Replies
- 10
- Views
- 950
Okay, good to know about the PVE -- the Daikin...
Okay, good to know about the PVE -- the Daikin doc never mentions
anything about oil type one way or the other, and I just assumed it was
POE. Having studied automotive coolant and brake-fluid... -
07-07-2012, 09:30 AM
Thread: inverter unit pumpdown
by hobbit- Replies
- 10
- Views
- 950
inverter unit pumpdown
In the process of fixing my flare leak (see the end of
my other thread ) my tech did something I thought was
... not necessarily impossible, but made somewhat difficult
on the newer systems. He... -
06-27-2012, 03:56 PM
Thread: careless commissioning?
by hobbit- Replies
- 16
- Views
- 1,295
Oh, and now the bad news. I just observed that...
Oh, and now the bad news. I just observed that the lineset
is leaking, right at the vapor-line flare nut.
Argh.
My guy is back here tomorrow anyway, and I guess he's
going to have a bit... -
06-27-2012, 02:37 PM
Thread: careless commissioning?
by hobbit- Replies
- 16
- Views
- 1,295
Sorry, was away over a long weekend... Outdoor...
Sorry, was away over a long weekend...
Outdoor unit is RZQ18PVJU9 inverter type,
indoor is FTQ18PAVJU upright ducted air handler,
remote-controller is BRC1E71 "Navigation" panel.
AHU will have... -
06-21-2012, 07:07 AM
Thread: careless commissioning?
by hobbit- Replies
- 16
- Views
- 1,295
Is it effective to throw in questions on a...
Is it effective to throw in questions on a slightly different issue
onto an older thread? After playing with the system for a few
days now, I've found that the blower *always* runs when the...
Results 1 to 25 of 38

