  1. Replies
    6
    Views
    488

    The lineset is the metering device and the indoor...

    The lineset is the metering device and the indoor unit is compatible with 410a
  2. Replies
    5
    Views
    560

    As long as the company, person installing has...

    As long as the company, person installing has insurance, and references, I would not. I was at one time. You can use a heat pump with a zone system. Arzel zone systems have the best warranty And as...
  3. Replies
    8
    Views
    4,954

    I'm installing a 5 and a 3 Tom Geo in a house and...

    I'm installing a 5 and a 3 Tom Geo in a house and it's 7000 Sq ft. 3500 on main and 3500 in basement. I sized for the house to be 75 at 0 outside on heating and 70 when it's 100 on cooling. Allot...
  4. Replies
    5
    Views
    2,666

    I'm doing a Geo job that has a 5 ton unit on...

    I'm doing a Geo job that has a 5 ton unit on first floor and 3 zones. If the right zone system is used. Jackson systems and arzel systems, I think are some of the best. They have a modulating bypass...
  5. Replies
    6
    Views
    2,807

    If your vents are in the floor on the outside...

    If your vents are in the floor on the outside wall, install return air on the inside wall roughly across from supply. You want the air exchage to pull up and across your room.
  6. Thread: Geo help!!

    by skeller
    Replies
    9
    Views
    1,978

    The installer can go back and rerun his design on...

    The installer can go back and rerun his design on a program for the loops and set the max water in at 90 or even 85 degrees. This will add footage on the loop but will help on the heat rejection....
  7. Replies
    5
    Views
    1,766

    I install all 2 stage units and this is the way...

    I install all 2 stage units and this is the way to go. The 2 stage is for you loads. When you don't have a high load it will run on 1st stage. Thus reducing energy consumption and you get all other...
  8. Replies
    18
    Views
    7,801

    Geo for hyronics

    You can use Geo for hydronics. You just have to find one made for it. If you just use a water to water unit, you will have to have to make sure that your btu output on your unit, for heating is the...
  9. Geo system

    Every time that I've seem a heatexchanger on a Geo go out is because the loop is not done correctly. I would be more than happy to help any way. My email is kellerhvac@gmail.com. Do you know how the...
  10. One key thing I've been doing for the past 10 yrs...

    One key thing I've been doing for the past 10 yrs on stats is caulking the hole in the wall. This will not allow the heat or cold from attic to come out the hole. Digital stats are more likely to...
  11. Replies
    15
    Views
    3,446

    Even with a manual j done, if the builder doesn't...

    Even with a manual j done, if the builder doesn't seal the house proper, you can have to much air infiltration. When Sheetrock is up and taped, have a blower door test done and you can see how bad it...
  12. Replies
    15
    Views
    3,446

    Geo comfort is not a bad choice. I install hydron...

    Geo comfort is not a bad choice. I install hydron module. They have the highest heating outputs and best warranty. They have lifetime on compressor, coaxial heat exchanger and cabinet. The rest has...
  13. Unit

    Just go with a hydron module. It's stainless steel heat exchanger and cabinet and has THE BEST WARRANTY on the market today guaranteed.
  14. Thread: Loop air

    by skeller
    Replies
    8
    Views
    1,952

    Air

    If the system was not flushed by at least a flow velocity of 2 feet per second, it could still have air in the system. Shut the system down and isolate the loops and pressure check with at least 40...
  15. Replies
    2
    Views
    1,907

    Header

    I seen them on eBay and I sent the link to my dealer and they just got them in. I'm using it on my next job and it's a pond loop
  16. Replies
    19
    Views
    9,070

    Geo is the only way

    Lp prices would have to be .22cents a gallon to be competitive with geo systems. If they are installed proper, loops too, you can get up to a cop of 5.1. The ground temp is at least a constant 55...
  17. Geo

    You can put a horizontal loop in but you need to know what type of soil you are. You can alwYs put a soaker hose in with the loops. If you are real interested then email me and i can go threw my...