Search:

Type: Posts; User: HighlandThunder

Page 1 of 2 1 2

Search: Search took 0.02 seconds.

  1. Replies
    20
    Views
    636

    Open Chrome, go to YouTube.com, scroll to the...

    Open Chrome, go to YouTube.com, scroll to the bottom of the page and click the link that says "Full Desktop Site" or something like that. Problem solved.

    The link to a video you clicked earlier...
  2. Replies
    7
    Views
    644

    For me, change out / install versus technical...

    For me, change out / install versus technical repair / diagnosis is as much a mental change as it is a tooling changed. I soooooo much prefer diagnosis & repair over full change outs but if tasked...
  3. Replies
    26
    Views
    2,034

    Yes! Good job finally getting pics up! I...

    Yes! Good job finally getting pics up! I personally have never worked on that particular model, so I can't get too technical about it which is good since we're talking about this in an open forum....
  4. Replies
    17
    Views
    1,557

    Tennessee recently (July, 2014) enacted a law...

    Tennessee recently (July, 2014) enacted a law that basically extends the "Castle" law to your personal vehicle. To summarize, there is no longer a restriction on carrying fully loaded firearms in...
  5. Replies
    26
    Views
    2,034

    I personally have never seen a residential heat...

    I personally have never seen a residential heat exchanger with any kind of opening to the living space air side unless it had failed such as rusted through or cracked, and my training has me flag any...
  6. Replies
    17
    Views
    1,557

    If the cans he gave you are Pyrodex then it is...

    If the cans he gave you are Pyrodex then it is most likely safe. Like you said, read the can and it should tell you. I always used Pyrodex in my muzzle loader as it is a lot less smoky than actual...
  7. Replies
    17
    Views
    1,557

    Yeah, I'm pretty sure the black item with the T...

    Yeah, I'm pretty sure the black item with the T handle is the percussion cap nipple removal tool / cleaner (brass handled needle thing), but I'm partially guessing as I have not seen that exact one...
  8. Replies
    4
    Views
    480

    Having a bit of trouble sleeping so I'm watching...

    Having a bit of trouble sleeping so I'm watching it now. Thanks for the suggestion, this is going to be interesting!

    Sent from my VS840 4G using Tapatalk
  9. BTW, reprogramming them requires a computer...

    BTW, reprogramming them requires a computer running special software and an interface cable.
  10. My understanding of the ol' X13 is that almost...

    My understanding of the ol' X13 is that almost every aspect of its operation is bench programmed into the motor, direction of rotation included. Even if you took one of the same horsepower and...
  11. Replies
    19
    Views
    1,928

    All I can tell you is that we've had some...

    All I can tell you is that we've had some personal experience with Chinese made black pipe that would come out just like what you've got in those pictures. We switched back to known quality pipe and...
  12. On the ones that are exhibiting the low suction...

    On the ones that are exhibiting the low suction pressure check to see if they installed the air handler in a manner where its return is tapped into the side of the cabinet instead of pulling through...
  13. Replies
    14
    Views
    3,248

    Coil looks good to me. I'm failing to see the...

    Coil looks good to me. I'm failing to see the failure. Rotting leaves can cause premature rustout on the bottom of an accumulator but this doesn't look like a heat pump.
  14. Replies
    8
    Views
    1,103

    Ooo, good catch! I didn't notice that the hoses...

    Ooo, good catch! I didn't notice that the hoses are on the blank holding nipples, not the pressure connections. Funny.
  15. Replies
    35
    Views
    2,885

    We had two Rheem / Ruud split heat pump outdoor...

    We had two Rheem / Ruud split heat pump outdoor units that had locked themselves out on low pressure, I am assuming, during the fairly harsh winter we had here in the Nashville TN area. Didn't find...
  16. Replies
    12
    Views
    1,770

    I can't imagine that exposed Romex going into the...

    I can't imagine that exposed Romex going into the bottom of the disconnect would pass a code inspection in any county. You say he's an electrician? Scarry. Duct work looks beautiful.
  17. "Neil" should be "Heil". Dang auto-correct.

    "Neil" should be "Heil". Dang auto-correct.
  18. Oops, it looks like you already knew that. :) ...

    Oops, it looks like you already knew that. :)

    On the one Neil packaged unit I've worked on that used this type of compressor it had Y1 & Y2 and the only way to put the compressor into 100% mode...
  19. Just wanted to chime in here real quick to...

    Just wanted to chime in here real quick to hopefully prevent you from frying that solenoid there. I'm pretty sure that is a DC voltage solenoid. Hopefully someone who knows a lot more than me about...
  20. Replies
    6
    Views
    704

    Was this a Polaris dealership? I've got a buddy...

    Was this a Polaris dealership? I've got a buddy from Sunday school who owns one of those Slingshots. It's fun to watch people walk by it. They always stop and stare for at least five seconds.
  21. +1 on that. Inquiring minds would like to know. :)

    +1 on that. Inquiring minds would like to know. :)
  22. Replies
    26
    Views
    2,259

    I have a customer with this compressor and the...

    I have a customer with this compressor and the solenoid shorted to ground blowing the control fuse. I just have him in 1st stage cooling, which is 67% of full capacity, and told him a new compressor...
  23. Replies
    8
    Views
    950

    x2 on the fishy part, and yes, I had something...

    x2 on the fishy part, and yes, I had something somewhat similar happen recently actually. Customer's only complaint and reason for having me out was for no heat getting to a couple rooms. Upon...
  24. I bet whomever installed that would also...

    I bet whomever installed that would also subscribe to the logic that "two ten inch returns are just as good as one twenty inch duct on this here 5 ton A/C!". :)
  25. Replies
    26
    Views
    3,284

    Only did it once. Purchased correct size bit from...

    Only did it once. Purchased correct size bit from local supply house, held each orifice with pliers and used a black n Decker plug in drill. Used a scratch awl to "x" our the old size and scratched...
  26. Replies
    20
    Views
    4,718

    prtadco, next time try holding down the alt key...

    prtadco, next time try holding down the alt key while typing 027 on the numeric keypad (normally far right side of keyboard) but first make sure numlock is on. That is the key code for esc. As soon...
  27. Replies
    10
    Views
    3,793

    The wife brined ours overnight in a water mixture...

    The wife brined ours overnight in a water mixture with a cup of salt and a cup of sugar. Cooked a little over 2 hours at 275 foil tented and breast down, then removed foil, upped oven temp around a...
  28. 7-10 is about right for here in middle Tennessee,...

    7-10 is about right for here in middle Tennessee, but a little closer to 7. In my experience these are the shortest lived AND most expensive inducers on the residential market. 90 out of 100 will...
  29. Replies
    72
    Views
    7,666

    Heck no! More power to them if they find a...

    Heck no! More power to them if they find a legitimate contractor willing to do it but I guarantee that our small company would not. The only customer purchased item I can remember ever installing is...
  30. Replies
    7
    Views
    1,064

    Yeah, I've had LCD multi-meters not display at...

    Yeah, I've had LCD multi-meters not display at all or only partially due to extreme cold. Also had one that I had left in direct sunlight too long that I could not read until it had cooled overnight....
  31. Replies
    9
    Views
    2,328

    Wow. The flex hiding in there is probably...

    Wow. The flex hiding in there is probably marginal to begin with and then if it is actually resting on that cross member then that is cutting out an extra 20% or more.
  32. Replies
    25
    Views
    3,317

    Also make sure your blower is running in heat...

    Also make sure your blower is running in heat mode and the indoor coil is clean. Either of those will go high on head in heat.
  33. Replies
    25
    Views
    3,317

    First thing that comes to mind is the outdoor...

    First thing that comes to mind is the outdoor coil TXV, assuming it's not piston instead. Fairly common failure is the tiny capulary tube connecting the sensing bulb has been rubbing on something and...
  34. Replies
    2
    Views
    1,301

    Your question got me curious since I had never...

    Your question got me curious since I had never tried saving other people's pictures viewed in Tap-a-Talk, so I gave it a try. If you tap on any particular picture to view it full screen you should...
  35. I have installed many of these with great success...

    I have installed many of these with great success when the flat part has rusted off the compressor terminals. It's called Term-Lok. Takes some time and patients to do properly, especially if you...
  36. Replies
    40
    Views
    4,566

    Three seasons ago we tried Super Seal on a...

    Three seasons ago we tried Super Seal on a handfull of residential systems and had the same results as many of you - half of the compressors locked rotor to where even a hard start would not get it...
  37. Replies
    48
    Views
    3,482

    Geodan, do you know about how hot your attic gets...

    Geodan, do you know about how hot your attic gets during the hottest part of summer in the afternoon?
  38. Replies
    21
    Views
    1,896

    Readings look great! If you're still on the call...

    Readings look great! If you're still on the call then be sure to double-check the tightness of the main voltage connections both in the disconnect and at the contactor and beware the contactor screws...
  39. Replies
    41
    Views
    4,497

    x2 We have a residential customer who has an...

    x2

    We have a residential customer who has an old Apollo AHU which has a slab evap coil in the bottom at an angle and if we don't clean that thing each spring with foaming coil cleaner (the brown...
  40. Replies
    7
    Views
    1,633

    You know, we had a customer years ago that...

    You know, we had a customer years ago that claimed another tech had cleaned the condenser coil with compressed nitrogen!?! Coil was still getting poor heat release. I dunno about types of dirt...
  41. Replies
    23
    Views
    2,708

    Don't want to get too technical in an open forum....

    Don't want to get too technical in an open forum. Suggestion, study your wiring diagram to get a good mental picture of the circuit then start testing at the beginning. If that gives a good voltage...
  42. Good example of how vacuum alone is not a...

    Good example of how vacuum alone is not a definitive leak eliminator. I like the idea of blocking off that part of the circuit if it is for sure only 10%, which will most likely not cause freezing.
  43. It'll cause slightly elevated humidity and grow...

    It'll cause slightly elevated humidity and grow all kinds of weird bacteria if it doesn't drain properly.

    My personal unit, mid 90's Trane packaged heat pump, had been slowly sinking on the...
  44. God bless you for not penetrating the furnace...

    God bless you for not penetrating the furnace cabinet with the yellow flex gas pipe. I cringe every time I see that around here.
  45. All automotive A/C systems I have worked on have...

    All automotive A/C systems I have worked on have to have continuous airflow across the condenser via fan-clutch mechanical or relay controlled electric fan and continuous airflow across the...
  46. That's pretty close to what I did. All joints...

    That's pretty close to what I did. All joints were glued and the threads so rusted around the fitting that it wouldn't budge without most likely breaking the threaded part off so I cut it about 3/4"...
  47. Replies
    7
    Views
    3,405

    Stupid reply reply, Florida heat pump - is that...

    Stupid reply reply, Florida heat pump - is that the brand and not the state?
  48. Replies
    7
    Views
    3,405

    Stupid reply time: You say this is a Florida...

    Stupid reply time: You say this is a Florida install so I may be way off base as it might not even have axillary heat, but if it does make sure you don't have a strip powered. And be sure to test for...
  49. Replies
    47
    Views
    4,717

    That's what I get for using a cheap meter to test...

    That's what I get for using a cheap meter to test caps. :D

    Guess I'll look into getting one a bit higher in quality like your sc76.
  50. Replies
    47
    Views
    4,717

    That's a good point, Solstice, a good start...

    That's a good point, Solstice, a good start capacitor can get a compressor going even when the run capacitor has severely weakened or gone bad, so that is a good reason to check those run caps while...
Results 1 to 50 of 75
Page 1 of 2 1 2

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech 365