Search:

Type: Posts; User: kangaroogod

Page 1 of 20 1 2 3 4

Search: Search took 0.07 seconds.

  1. Replies
    4
    Views
    204

    You can look up the disassembly online at mits...

    You can look up the disassembly online at mits tech site... The first one will take an hour and then they get easier and it can be removed in 5-10 minutes


    Sent from my iPhone using Tapatalk
  2. Replies
    4
    Views
    204

    Cleaning ductless fan

    20 minutes out and in for a Mitsubishi... Funnel?? I have seen cleaning bags that you put underneath but they are foolish if you are some experience removing wheels


    Sent from my iPhone using...
  3. Replies
    4
    Views
    216

    I have several on ups. The others I sold them a...

    I have several on ups. The others I sold them a home standby generator :)


    Sent from my iPhone using Tapatalk
  4. It should be fine,,,, doesn't condense much

    596601


    Sent from my iPhone using Tapatalk
  5. I use an angle grinder with a diamond blade ...

    I use an angle grinder with a diamond blade


    Sent from my iPhone using Tapatalk
  6. Replies
    0
    Views
    354

    My first experience with stride tool

    I have a bunch of burnishing tools out there with techs. One of my techs called me and had an issue with his. The pin that hold the handle broke and the threads were stripped out. This was hardly...
  7. Replies
    12
    Views
    428

    Taking a guess you live in a manufactured home?

    Taking a guess you live in a manufactured home?
  8. Replies
    8
    Views
    1,314

    http://images.tapatalk-cdn.com/15/06/08/677617c3d9...

    http://images.tapatalk-cdn.com/15/06/08/677617c3d94f6aba2e14426de7196c65.jpg

    I would use this :)
  9. It interfaces as a dry set of contacts ...

    It interfaces as a dry set of contacts

    Generally 1

    No stages

    Generally no fan unless a hot water coil is used

    N/a
  10. Replies
    8
    Views
    482

    It is a flame sensor and has been discontinued to...

    It is a flame sensor and has been discontinued to the best of my knowledge several years ago


    Sent from my iPhone using Tapatalk
  11. If you installed a drier you will also have to...

    If you installed a drier you will also have to add for it. I 'believe' if the drier comes with the unit that it is accounted for?


    Sent from my iPhone using Tapatalk
  12. Replies
    107
    Views
    9,310

    X3 on my bluvac also. It said oil then went...

    X3 on my bluvac also. It said oil then went away.. I did the isopropyl thing and haven't tried it again yet.


    Sent from my iPhone using Tapatalk
  13. With the fuel tank cost,, I think propane sounds...

    With the fuel tank cost,, I think propane sounds like a good plan. Combo boilers have there place. What water temperature does your boiler operate at? I have worked in many kinds of wall hung...
  14. Jeepers... looking at the manual for that unit,...

    Jeepers... looking at the manual for that unit, the control board is anything but universal. Looks like a condensing oil boiler with very proprietary parts. While I have never worked on that unit, I...
  15. Replies
    6
    Views
    766

    I had mine set up in our lab. I was about 130'...

    I had mine set up in our lab. I was about 130' away, through 2 different hallways and thought 2 walls. I had my 440 and sdp2 synced and monitoring performance on a lab unit from my office.
  16. Replies
    37
    Views
    1,172

    I usually use Acid away, biflow ll and biflow...

    I usually use Acid away, biflow ll and biflow suction driers. Sporlan does make bi sol but they are special order.


    Sent from my iPhone using Tapatalk
  17. Replies
    13
    Views
    662

    I would doubt it is a panel issue and more of a...

    I would doubt it is a panel issue and more of a thermostat compatibility issue
  18. Replies
    11
    Views
    871

    R6?? Not around here you can't if it is outside...

    R6?? Not around here you can't if it is outside the thermal envelope of the home
  19. Replies
    6
    Views
    583

    Mitsubishi makes a mhk kit for use with...

    Mitsubishi makes a mhk kit for use with compatible heads. It is a wireless honeywell 6000 stat and also needs an Internet gateway (added cost) to operate the Internet portion.
  20. Your only benefit really will be at startup and...

    Your only benefit really will be at startup and shutdown to prevent slight sooting. If you are not experiencing this,, then I wouldn't bother


    Sent from my iPhone using Tapatalk
  21. Replies
    18
    Views
    1,643

    It works awesome! Very impressive app so far and...

    It works awesome! Very impressive app so far and with the developing software in the future I think it is a no brainier. Analog and paper is for the kids,, digital and technology is what allows me to...
  22. Replies
    8
    Views
    466

    Gas conversion burners.

    Gas conversions on a oil Boiler would be fairly common (I did one a few months ago). Converting a forced air Thermopride would not be recommended. Although that is the best oil furnace in the...
  23. Replies
    16
    Views
    709

    I am sure that a local contractor would hook you...

    I am sure that a local contractor would hook you up. Easy changeout and you would get a good relationship established for your future needs.
  24. Replies
    16
    Views
    709

    Yank the taco and install a grundfos. Problem...

    Yank the taco and install a grundfos. Problem solved (the flanges are opposite
  25. Replies
    16
    Views
    752

    I will store that away in the i will need that...

    I will store that away in the i will need that someday section of the brain... like it lots
  26. Replies
    9
    Views
    544

    Recirculation or gas/air adjustment. Call navien

    Recirculation or gas/air adjustment. Call navien
  27. Replies
    3
    Views
    249

    Hw focuspro 6000 is rated for mv pretty sure

    Hw focuspro 6000 is rated for mv pretty sure
  28. Replies
    87
    Views
    13,392

    Whistle Sent from my iPhone using Tapatalk

    Whistle


    Sent from my iPhone using Tapatalk
  29. Adding insulation to the piping can only be a...

    Adding insulation to the piping can only be a benefit to you. Removing it can only hurt your situation. If space in a concern then removing the boxes and insulating with 3" fiberglass pipe insulation...
  30. Replies
    10
    Views
    521

    The inspector is partially correct. His theory is...

    The inspector is partially correct. His theory is that since the heat of the furnace no longer exists and the water heater is the only appliance in the vent, condensation could form in the vent. This...
  31. Hot water and adding a booster fan to increase...

    Hot water and adding a booster fan to increase the volume of air across the humidifier pad will work wonders. You have a 2 stage furnace which is good but long run times on low stage with a variable...
  32. Replies
    8
    Views
    625

    It called motor cogging,, I am fighting one...

    It called motor cogging,, I am fighting one myself. It is an inherent noise of vs motors. When voltage is applied to to motor, it can spin backwards depending on where the magnets are. It sometimes...
  33. Replies
    9
    Views
    1,231

    Field controls makes a combustion air intake kit...

    Field controls makes a combustion air intake kit called a fan in a can.. they work great. It will add a motor and potential repair costs down the road but it has an interlock switch to ensure the air...
  34. Yank the motor and a little diluted calclean HD...

    Yank the motor and a little diluted calclean HD and good as new
  35. Replies
    1
    Views
    361

    I scanned one on a Rheem and was depressed to see...

    I scanned one on a Rheem and was depressed to see a parts section.. seriously? We install your product and you pimp others???? It was a whole Lotta nothin...
  36. Replies
    11
    Views
    709

    I would check out arzel... disclaimer that I have...

    I would check out arzel... disclaimer that I have never used Jackson as I have never seen a need to
  37. If the space Is wide open it would be fine with 1...

    If the space Is wide open it would be fine with 1 head
  38. Easily Sent from my iPhone using Tapatalk

    Easily


    Sent from my iPhone using Tapatalk
  39. Adams is a horror show. Thermopride just came out...

    Adams is a horror show. Thermopride just came out with a condesing oil.. haven't seen one in person but love the company.
  40. Replies
    7
    Views
    644

    I live 30 miles east and got 38", no good...

    I live 30 miles east and got 38", no good stories. My 4wd on my plow truck took a dump that day...


    Sent from my iPhone using Tapatalk
  41. Replies
    35
    Views
    3,098

    Could easily sleeve the control wire in 3/8 Vinal...

    Could easily sleeve the control wire in 3/8 Vinal tubing


    Sent from my iPhone using Tapatalk
  42. Replies
    3
    Views
    2,252

    Around here, an oil filter is never installed...

    Around here, an oil filter is never installed outdoors. I prefer. Tiger loop ultra


    Sent from my iPhone using Tapatalk
  43. The home has a tag depicting the heat loss at a...

    The home has a tag depicting the heat loss at a given temperature. It would be located by your electrical panel or in some cases in the master closet


    Sent from my iPhone using Tapatalk
  44. I would go with the 8523 though. The rubber boot...

    I would go with the 8523 though. The rubber boot is great as it is magnetic. Just slap it on the side of the unit. The hard case will help if it gets banged around in the van


    Sent from my iPhone...
  45. Field replaceable "b-smart" sensors. They send...

    Field replaceable "b-smart" sensors. They send you a new sensor and you return the old in a package they send you


    Sent from my iPhone using Tapatalk
  46. I have ordered and have about 15 of them in the...

    I have ordered and have about 15 of them in the field. (ordered 2 from ttt yesterday). They are good units but it seems the oxygen sensors are prone to dying pretty quick. I have had 3 fail within a...
  47. Replies
    15
    Views
    918

    Could go with (2) 600's? Sent from my iPhone...

    Could go with (2) 600's?


    Sent from my iPhone using Tapatalk
  48. Replies
    30
    Views
    9,331

    I ordered a dozen from my local vendor. Part...

    I ordered a dozen from my local vendor. Part number in the link.
    http://herchem.net/specs/UnPurple.pdf


    Sent from my iPhone using Tapatalk
  49. Love it! Sent from my iPhone using Tapatalk

    Love it!


    Sent from my iPhone using Tapatalk
  50. Replies
    28
    Views
    2,049

    I am going to follow this thread. I have seen...

    I am going to follow this thread. I have seen numerous goodman Gmh with co In the 200-300. I spend many many hours Testing one from orifice sizing, clocking the meter, delta. T , venting to come to...