Search:
Type: Posts; User: DethWshBkr
Search: Search took 0.00 seconds.
-
12-12-2010, 06:22 PM
Thread: Weatherking Rooftop
by DethWshBkr- Replies
- 2
- Views
- 813
Weatherking Rooftop
Have a buddy who just asked me about heat exchanger repair on a Weatherking rooftop unit.
It is breached and needs repaired / replaced. He heard from the company that they are going to have... -
11-02-2010, 01:04 AM
Thread: Powermate stair climbing hand truck
by DethWshBkr- Replies
- 11
- Views
- 3,799
Anything new on these? I've been in contact with...
Anything new on these? I've been in contact with Powermate for many months now, but can't bite on such an expensive hunk of equipment.
I'm a 1 man operation though, and I KNOW these things would... -
06-26-2010, 12:33 AM
- Replies
- 20
- Views
- 3,478
Let me get this straight - the doctors placed his...
Let me get this straight - the doctors placed his mortality likelyhood LOWER by having an open, obviously dirty, rough cut arm bleeding everywhere, while drinking boiler water for two days, than by...
-
06-24-2010, 12:00 AM
Thread: temp at register
by DethWshBkr- Replies
- 16
- Views
- 843
Certainly colder than the house - but other than...
Certainly colder than the house - but other than that - yeah, it could be 70, it could be 50, depending on the indoor temp, and a lot of other variables.
-
06-23-2010, 09:33 PM
Thread: Strange issue in split-level home
by DethWshBkr- Replies
- 9
- Views
- 2,900
How about as a temporary thing - partially close...
How about as a temporary thing - partially close the vents downstairs, and turn your fan to "on" instead of auto. It will constantly circulate the air, at least that should help until it gets fixed...
-
06-23-2010, 01:25 PM
Thread: Too dumb for words
by DethWshBkr- Replies
- 10
- Views
- 1,864
Doh! My heating instructor, the first thing...
Doh!
My heating instructor, the first thing he said in the first class on troubleshooting
"MAKE SURE THE THERMOSTAT IS CALLING"
Yet, for some reason, everyone seems to at some point in time,... -
06-22-2010, 10:58 PM
- Replies
- 20
- Views
- 3,478
I'm sorry, but this guy is an IDIOT. From what...
I'm sorry, but this guy is an IDIOT.
From what I remember reading (and posting on my facebook rant), He started cutting his arm off after being stuck for 12 hours.
I mean, seriously? 12... -
06-20-2010, 11:14 PM
Thread: new Goodman air handler has no bottom?
by DethWshBkr- Replies
- 35
- Views
- 2,762
Ouch. Someone needs to be fired.
Ouch.
Someone needs to be fired. -
06-16-2010, 12:36 AM
Thread: The whole manual J thing
by DethWshBkr- Replies
- 21
- Views
- 1,056
Gotcha. I guess it's just more training, and...
Gotcha. I guess it's just more training, and surely, more training than I ever have even heard about before. No doubt more than anyone I've worked for before is aware of as well.
Infact, when I... -
06-15-2010, 10:58 PM
Thread: The whole manual J thing
by DethWshBkr- Replies
- 21
- Views
- 1,056
So then again, where is that threshold? Perhaps...
So then again, where is that threshold? Perhaps it's just something I have not been trained properly for, but what is the threshold that tells you an 18000 btu unit will not work on a 13000 btu...
-
06-15-2010, 09:54 PM
Thread: The whole manual J thing
by DethWshBkr- Replies
- 21
- Views
- 1,056
.
.
-
06-15-2010, 09:53 PM
Thread: The whole manual J thing
by DethWshBkr- Replies
- 21
- Views
- 1,056
I put average construction quality, design temps...
I put average construction quality, design temps 70 summer, 69 winter, 55% rh, heat pump.
Outdoor condition design at 95/11, 100 grains, medium swing.
It says just under 13,600btu sensible,... -
06-15-2010, 06:14 PM
Thread: The whole manual J thing
by DethWshBkr- Replies
- 21
- Views
- 1,056
So then what is the threshold for "too large" a...
So then what is the threshold for "too large" a system?
Obviously, if we have a 25,000btu need, a 1.5 ton system is too small. In theory, so is a 2 ton system during max load. At what point is it... -
06-15-2010, 07:40 AM
Thread: The whole manual J thing
by DethWshBkr- Replies
- 21
- Views
- 1,056
Oh, the system keeps temp in the house at any...
Oh, the system keeps temp in the house at any outdoor ambient. We did have humidity issues, again, to where I blocked off 1/2 of my filter. Now, we hit 50-55% easy.
And no, I did not... -
06-15-2010, 12:41 AM
Thread: The whole manual J thing
by DethWshBkr- Replies
- 21
- Views
- 1,056
The whole manual J thing
I wonder how often it is used, and really, what is the major necessity. I know it makes it "better", but really?
I had a few posts a while back, saying how I had blocked off half my 20x20 filter... -
06-12-2010, 12:49 AM
Thread: new grads...what do employers want?
by DethWshBkr- Replies
- 26
- Views
- 2,270
Exactly. Everyone can say "It was a little low...
Exactly. Everyone can say "It was a little low on freon last year" and so they figure they are making sure you know what to do....
-
06-12-2010, 12:47 AM
Thread: new grads...what do employers want?
by DethWshBkr- Replies
- 26
- Views
- 2,270
Most schools. If not, they wouldn't use HVAC/R...
Most schools.
If not, they wouldn't use HVAC/R as the "fallback" course, in case a student can't hack it in something else, they should then check out hvac.
It's not a statement that has ever... -
06-09-2010, 12:41 AM
Thread: new grads...what do employers want?
by DethWshBkr- Replies
- 26
- Views
- 2,270
I think a lot of it is just a lack of good...
I think a lot of it is just a lack of good candidates.
Anyone can be trained properly, but are they a good candidate?
I graduated from YTI in York, PA.
Well, I recently found out that they are... -
06-05-2010, 11:17 PM
Thread: Oh jeez.
by DethWshBkr- Replies
- 17
- Views
- 780
Correct, I have not been to the house yet. I...
Correct, I have not been to the house yet.
I again, did tell them not to run it, but I was pretty much told that is probably not going to happen.
Unless it was an absolute safety hazard, I... -
06-05-2010, 08:06 PM
Thread: Oh jeez.
by DethWshBkr- Replies
- 17
- Views
- 780
How am I to do that!? I did tell them to not...
How am I to do that!? I did tell them to not use it....
I did get the model, serial, and mfg, and approximate diameter of the blade, and blade angle. But yeah, United should be able to... -
06-05-2010, 06:17 PM
Thread: Oh jeez.
by DethWshBkr- Replies
- 17
- Views
- 780
Oh jeez.
I just had a customer call me, their AC isn't working.
OK, not a big deal, I can fix it!
Well if it survives.
They said that one of the two fan blades broke off, so they duct taped it on. ... -
06-02-2010, 01:15 PM
Thread: Coil Cleaners
by DethWshBkr- Replies
- 13
- Views
- 1,030
So now, would it be a bad idea to use the green...
So now, would it be a bad idea to use the green Kleen Coil stuff, which is for evaps on an outdoor unit? I am not talking about paint removal and such, as more than likely, especially with what I...
-
06-01-2010, 11:51 PM
Thread: Coil Cleaners
by DethWshBkr- Replies
- 13
- Views
- 1,030
Probably not even necessary, but I know we can...
Probably not even necessary, but I know we can get a lot of mud and junk buildup on the coil if the homeowner is careless (which some are more of rather than less) combine that with spider webs,...
-
06-01-2010, 11:13 PM
Thread: Offer help and they run!!
by DethWshBkr- Replies
- 6
- Views
- 645
I guess when you feel like you get screwed by...
I guess when you feel like you get screwed by contractors left and right, it's hard to imagine otherwise. So, it's a shame, but a shame on which end though?
-
06-01-2010, 11:08 PM
Thread: Coil Cleaners
by DethWshBkr- Replies
- 13
- Views
- 1,030
Coil Cleaners
What is everyone's favorite pick for coil cleaners?
Concentrate? Foamy no rinse? Evaporator specific? Condenser specific?
I purchased some of the green concentrated Kleen Coil from United...
Results 1 to 25 of 96