02-23-2005, 12:30 AM
Thread: On site programming
by floating point- Replies
- 13
- Views
- 1,845
Byer folding wood rocking chair....
Byer folding wood rocking chair. 24"x36"x2"....... Oh yea and my lap. And a bunch of cables and adapters!
It would be nice if I could use the Palm for more than the VMA's
Somebody needs to... -
02-22-2005, 11:37 PM
Thread: 4 Ton Process Chiller
by floating point- Replies
- 3
- Views
- 802
I have been trying to find a small water-to-water...
I have been trying to find a small water-to-water chiller. So far I am going to bid it with a Drake, or a Trane WPWD heat pump. According to the reps the Drake is a bit more than the Trane. Any...
-
02-18-2005, 11:51 PM
Thread: Chilled water valve action
by floating point- Replies
- 6
- Views
- 1,261
2-10 or 4-20, only use floating if you have to,...
2-10 or 4-20, only use floating if you have to, and don't use on/off, IMHO
-
02-03-2005, 11:36 PM
Thread: trane bcu display
by floating point- Replies
- 11
- Views
- 2,321
I also have dealt with this situation. You do...
I also have dealt with this situation. You do need a version of summit that is = to or newer than the version on site if you are dialing in to the BCU.
I proposed using VNC to connect to the... -
01-29-2005, 01:52 AM
Thread: Visual Test Shell for BACNET
by floating point- Replies
- 10
- Views
- 2,159
I know BACnet has a ways to go still but I think...
I know BACnet has a ways to go still but I think that tools such as VTS, BACnet4linux, and SCADA Engine's RDK help to advance it.
I also agree that there needs to be a common setup tool with... -
01-29-2005, 01:11 AM
Thread: unt going offline intermittently
by floating point- Replies
- 8
- Views
- 1,265
Too bad there isn't a protocol analyzer for N2. ...
Too bad there isn't a protocol analyzer for N2. Sure would make it alot easier to see what is going on with the network.
If it has worked well before then I would also agree with it being a bad... -
01-26-2005, 09:23 PM
Thread: Delta Controls automation
by floating point- Replies
- 31
- Views
- 5,062
The program differences are Iterm (Dos terminal...
The program differences are Iterm (Dos terminal type), IgraphW (Windows terminal type), Commander (Windows GUI). The newest Commander I have used is 3.10 so I am not much help on the newer stuff. ...
-
01-25-2005, 09:55 PM
Thread: Delta Controls automation
by floating point- Replies
- 31
- Views
- 5,062
If you are using DCU050's make sure you change...
If you are using DCU050's make sure you change the batteries every so often (While powered on of course). Make sure you back up the databases. What software do you have to access Iterm, IgraphW,...
-
01-24-2005, 04:24 PM
Thread: Visual Test Shell for BACNET
by floating point- Replies
- 10
- Views
- 2,159
I understand that Lon is a more robust protocol...
I understand that Lon is a more robust protocol and devices don't need to be tested for functionality.
I think you missed my point that this is an open source test tool and kind of a protocol... -
01-24-2005, 02:07 AM
Thread: Visual Test Shell for BACNET
by floating point- Replies
- 10
- Views
- 2,159
sourceforge.net/projects/vts/ Check it out!!, ...
sourceforge.net/projects/vts/
Check it out!!, Hey Sysint, where's the Lon version? -
01-24-2005, 01:51 AM
Thread: did we forget about PNEUMATIC>>>
by floating point- Replies
- 68
- Views
- 5,623
Just my take on it but I think PNEU is dying. ...
Just my take on it but I think PNEU is dying. Why would anyone want to stay with it? How much does it cost to keep the compressor and drier running not to mention the service calls to figure out...
-
01-23-2005, 11:51 PM
Thread: 4-20ma-0-10vdc output box
by floating point- Replies
- 13
- Views
- 6,769
I have also used a JCI A350P for a long time (Way...
I have also used a JCI A350P for a long time (Way to think out of the box, bobbym).
The only drawback is having to drag around a cord but it didn't cost me anything as it was also a takeout from a... -
01-13-2005, 10:46 PM
Thread: Metasys Companion
by floating point- Replies
- 6
- Views
- 2,664
I kinda got a little carried away with this but...
I kinda got a little carried away with this but oh well.
I chucked the old 2400 baud external modem that was for remote access and ran a RS-232 cable over to a newer machine running XP. That... -
01-03-2005, 08:16 PM
Thread: Metasys Companion
by floating point- Replies
- 6
- Views
- 2,664
Thanks joey that's what I was looking for. I did...
Thanks joey that's what I was looking for. I did search I just missed it somehow.
I know this is an old product and not really supported anymore, I was just wondering if JCI had any PC based... -
12-29-2004, 09:18 PM
Thread: Metasys Companion
by floating point- Replies
- 6
- Views
- 2,664
Does anybody know if the companion tech manual is...
Does anybody know if the companion tech manual is available in pdf? I used to have a hard copy but I cannot find it.
I have a site that has an old dos PC based companion (R2.0). They have been... -
12-21-2004, 10:48 PM
- Replies
- 22
- Views
- 3,382
There are different areas in controls just like...
There are different areas in controls just like any other trade. Your HVAC experience is not going to help if you are getting a job with a company that does mainly lighting and access control,...
-
12-17-2004, 11:29 PM
Thread: xl10 VAV's
by floating point- Replies
- 7
- Views
- 794
I thought I was missing som ting. Hold time...
I thought I was missing som ting.
Hold time for Occ state =900 sec. ( Or 15min )
for leviton brand
nci01HoldTime = Range 5...6553.4 sec
Format: SNVT_time_sec -
12-17-2004, 09:57 PM
Thread: Trane BCU and ethernet
by floating point- Replies
- 9
- Views
- 1,310
I have two Trane arcnet cards NIB. Not sure if...
I have two Trane arcnet cards NIB. Not sure if they are the ones you are needing but they are real cheap!!
-
12-16-2004, 12:45 AM
Thread: MUST be a CONTROL PROBLEM
by floating point- Replies
- 13
- Views
- 1,348
A couple weeks ago it was the coldest it's been...
A couple weeks ago it was the coldest it's been this year (-8 F).
Customer called to see if I could manually turn off the compressors. It was blowing 40 F air into the offices. (The office with... -
12-15-2004, 11:47 PM
Thread: Air filter pressure monitoring
by floating point- Replies
- 10
- Views
- 1,263
I have always used a dwyer incline gauge with a...
I have always used a dwyer incline gauge with a differential pressure switch as a dirty filter indicator.
If you are at the site often enough there is no reason for a true differential pressure... -
12-02-2004, 04:35 PM
Thread: Robertshaw 2616 EMS
by floating point- Replies
- 6
- Views
- 752
Thank you for taking the time to scan the manual....
Thank you for taking the time to scan the manual. It was a big help.
-
11-28-2004, 12:25 AM
Thread: Setback of domestic
by floating point- Replies
- 3
- Views
- 645
I know it's kinda off topic, but... I just...
I know it's kinda off topic, but...
I just rebuilt a Minimax 400k btuh copperfin for a pool. (New HX, baffles, flow valve & switch, limits, P&T, wiring harness) The pool was down to 65 on... -
11-27-2004, 11:38 PM
Thread: xl 15
by floating point- Replies
- 28
- Views
- 2,668
Webtool or xBuilder.
Webtool or xBuilder.
-
11-27-2004, 11:27 PM
Thread: Robertshaw 2616 EMS
by floating point- Replies
- 6
- Views
- 752
If you would be willing to scan it that would be...
If you would be willing to scan it that would be great!!
Is there a way of bypassing it until I can program the schedules? The AHU's I need to start-up had no power to them and I'm hoping they... -
11-27-2004, 04:20 PM
Thread: xl 15
by floating point- Replies
- 28
- Views
- 2,668
The xl 15b seems like a good product and it is...
The xl 15b seems like a good product and it is easier to use (if you are using strictly HW LCBS) but it is still too limited for my use and way overpriced IMHO. (4 times the cost of the ilon100)
...
Results 1 to 25 of 76