Search:

Type: Posts; User: Paymemore

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Thread: help im slow

    by Paymemore
    Replies
    3
    Views
    406

    wow you are awsome. thank you very much!!!

    wow you are awsome. thank you very much!!!
  2. Thread: help im slow

    by Paymemore
    Replies
    3
    Views
    406

    help im slow

    Ok, so I feel like a tool for not knowing this, but please help me! All my threads are backwards when I open them... when I open a thread to comment it starts from the newest message first. really...
  3. Replies
    8
    Views
    1,725

    If you are running 900 fpm then 12 is too small,...

    If you are running 900 fpm then 12 is too small, you should have a 14 in return atleast. General rule of thumb is over size return one size since it isnt going to hurt it, but if you undersize it can...
  4. Replies
    8
    Views
    529

    Have you thought about seeing if your system can...

    Have you thought about seeing if your system can be zoned? That would be your permanent solution to this. Any HVAC company should be able to install a wireless Tstat for you, but i would have them...
  5. Replies
    5
    Views
    652

    Go with the honeywell and with the HZ322 zone...

    Go with the honeywell and with the HZ322 zone board. Have installed many of these and havent had an issue yet, other then the tstat is battery operated obviously.
  6. Replies
    12
    Views
    475

    what kind of water heater is it? Gas or electric?...

    what kind of water heater is it? Gas or electric? On an electric you normally have 2 sets of elements, you might have one setup higher then the other. If you are getting that much of a difference all...
  7. Replies
    2
    Views
    484

    Works just like a normal furnace does, with your...

    Works just like a normal furnace does, with your furnace actually only coming on when design conditions are met. Like Emergency heat and below a certian temp outside.
  8. Replies
    12
    Views
    742

    I would have to go with big sky on this. Not much...

    I would have to go with big sky on this. Not much of what you are saying makes sense at all. Unit is oversized, but matched old unit? How do you know it oversized? Your saying that you installed a...
  9. Replies
    9
    Views
    489

    Sounds like next time you shouldnt take a lunch...

    Sounds like next time you shouldnt take a lunch break in the middle of it. Seriously though 4 hrs sounds about right to me, maybe he was thinking you didnt need to vacuum the lines or recover, some...
  10. Replies
    7
    Views
    1,318

    Sounds like negative pressure to me. Is it just...

    Sounds like negative pressure to me. Is it just when the A/c is running? It can also be caused by driers, and bathroom fans running, a house always has to have some leakage, and you want it to come...
  11. Replies
    13
    Views
    1,371

    Could have been the problem. But without enough...

    Could have been the problem. But without enough info no one can tell you what was going on with the system. It might have been a start to see if it worked, however, if there was a problem with lines...
  12. Replies
    44
    Views
    5,011

    Water is for drinking!?:cheers:

    Water is for drinking!?:cheers:
  13. Replies
    44
    Views
    5,011

    How you maintain units at a Residence vs a...

    How you maintain units at a Residence vs a commercial is the same? Commercial units are normally exposed to alot of things that residential units are not, me personally havent seen to many...
  14. Replies
    44
    Views
    5,011

    So what I said was baloney? As it goes for...

    So what I said was baloney? As it goes for common house hold cleaners alot of them leave a residue behind. And you think that someone without the sense to use sound judgment on when coil cleaner...
  15. Replies
    25
    Views
    5,027

    they are right. you will notice if you run the...

    they are right. you will notice if you run the exhaust fan in your bathroom and close the door, the bathroom will smell strongly of smoke, more than the rest of the house! get a box fan in the...
  16. Replies
    34
    Views
    3,303

    one of my good friends left residential to go...

    one of my good friends left residential to go back to the supermarkets and restaurant equipt walk in coolers and such. he just did not like residential. different strokes for different folks. he...
  17. Replies
    25
    Views
    6,223

    Is that really a clothing dryer venting into a...

    Is that really a clothing dryer venting into a crawl space? It's a wonder the place hasn't burned down .... lol
  18. Replies
    154
    Views
    29,419

    Around here you start as a helper at 10 bucks an...

    Around here you start as a helper at 10 bucks an hour, maybe 11 if you already have your EPA. Once you get your own van and start PMs or something like that you are 12-14 and installers a little...
  19. I lean towards Replace the system if you can...

    I lean towards Replace the system if you can afford it, just less problems down the road but this question could be complicated by other factors as you can see. The great thing is if you buy one of...
  20. Never forget your flash light / head lamp!!!

    Never forget your flash light / head lamp!!!
  21. Replies
    44
    Views
    5,011

    maybe you can state how this is "Baloney"? or...

    maybe you can state how this is "Baloney"? or maybe just posting it makes it so? Have you ever seen a unit with adsil after it has been "cleaned"? or do you think that black stuff that comes from...
  22. Replies
    21
    Views
    1,214

    It could be a blessing in disguise... Three of my...

    It could be a blessing in disguise... Three of my closest neighbors have knocked or came by and they always want free stuff....
  23. Replies
    21
    Views
    2,643

    There is work but the pay scale is def. lower...

    There is work but the pay scale is def. lower here than in some other places. Not many union shops either, that is true
  24. Replies
    16
    Views
    3,081

    More than likely the well isnt big enough to...

    More than likely the well isnt big enough to supply what is needed to the geo. You can really go two ways with it, bigger well pump, or closed loop.
  25. Replies
    44
    Views
    5,011

    Never use coil cleaner unless you have to. And...

    Never use coil cleaner unless you have to. And even then use the most basic one you can get away with. It is ok to use evap cleaner on an o/d coil if you need to. You have to remember those cleaners...
Results 1 to 25 of 37
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event