  1. Replies
    20
    Views
    3,031

    You guys have too much time on your hands.

    You guys have too much time on your hands.
  2. Replies
    17
    Views
    1,306

    Had 1 site where advisories were already disables...

    Had 1 site where advisories were already disables and it crashes.
  3. Replies
    17
    Views
    1,004

    The "Engineered Specs" were not from the factory...

    The "Engineered Specs" were not from the factory they were from the Engineering Co. that is designing the job.

    It all pretty much comes down to people not reading what they bid on, even when the...
  4. Replies
    17
    Views
    1,004

    Factory rep = Unit Manufactures Rep.

    Factory rep = Unit Manufactures Rep.
  5. Replies
    17
    Views
    1,004

    There is an ERU on the job. Part of the...

    There is an ERU on the job. Part of the Engineered Spec states that "Factory control package "must" be used and under no circumstance is the ATC contractor to install field device to control said...
  6. Replies
    17
    Views
    1,004

    Submittals VS Specs.

    On job now where my Submittal specs. do not match my Engineered specs.. I am being told the Engineering Co. approved our Submittals so where all set. Wondering what trumps what? Hate being...
  7. Replies
    12
    Views
    825

    Curious why you say that Max master can't be...

    Curious why you say that Max master can't be adjusted on Spyders? Just set a bunch, do they not respond to setting even when set?

    I did see that that when trying to set Max Master on an Off-line...
  8. Replies
    10
    Views
    609

    The writable AV 165 Supply Fan Speed is writable...

    The writable AV 165 Supply Fan Speed is writable but unit only responds to it when in test mode.

    Already have 2 static pick ups tee'd together but even the slight difference between readings cause...
  9. Replies
    10
    Views
    609

    Carrier A-series RTU question

    Have 2 A-series VAV RTUs that share common duct, both run a same time, no isolation dampers. Trying to find a way to write the speed from one to the other so they track together. Found a writable but...
  10. Replies
    7
    Views
    484

    Are you hooking up to a Security Jace?

    Are you hooking up to a Security Jace?
  11. Replies
    12
    Views
    977

    Unsure if you tried sending, but did not receive.

    Unsure if you tried sending, but did not receive.
  12. Replies
    12
    Views
    977

    Email in profile. Thanks :cheers::cheers:

    Email in profile. Thanks :cheers::cheers:
  13. Replies
    0
    Views
    324

    N4.1 Demo Station

    Station won't start due to.


    SEVERE [18:05:27 24-Mar-16 EDT][sys] Cannot load station
    javax.baja.xml.XException: Invalid module attribute 'dd=demoData' [5783:84]



    Have module installed....
  14. Replies
    2
    Views
    316

    Found out it won't download using Firefox. OK...

    Found out it won't download using Firefox. OK with IE.
  15. Replies
    2
    Views
    316

    Open LDV 5 network driver for Windows

    Anyone have this driver software. Tried to download it from Echelon site but wouldn't work.
  16. I always mount NO2 couple feet from deck, fans at...

    I always mount NO2 couple feet from deck, fans at .7ppm, alarm at 2ppm. CO at 5' fans at 25 ppm, alarm at 100 ppm
  17. Replies
    17
    Views
    1,568

    I live in Spyderland. Use them all the time....

    I live in Spyderland. Use them all the time. Don't know if I like them or not, I just work with them.
  18. Thread: Parker VVT

    by mechmike2
    Replies
    4
    Views
    808

    might have some, have to check shop. Should add...

    might have some, have to check shop. Should add your email to your profile.
  19. Replies
    6
    Views
    557

    malicious site warning

    I keep getting this warning. Is something wrong with the site? Get it in both Firefox and IE
  20. Replies
    24
    Views
    1,768

    Took an advanced class that James Johnson from...

    Took an advanced class that James Johnson from Tridium (Vykon) put on, think it was 5 day. Lots of info, My head hurt. Good docs I still use. Would recommend.
  21. I had 4 RTUs all configured the same in both AX...

    I had 4 RTUs all configured the same in both AX and Field Assistant. 1 of the units would always read 100 degree return temp. I can't recall exactly how I got it to stop and read properly. I know it...
  22. I had the same problem, except it was 100. Had to...

    I had the same problem, except it was 100. Had to use Carrier Field Assistant and go into the UPC Open controller and in the property sheet view of the RA Temp tell it to not allow writing to the...
  23. Replies
    1
    Views
    269

    Solidyne to Ax

    Anyone integrated Solidyne controllers into a Jace using their M2 driver? How did it go?
  24. Replies
    3
    Views
    374

    Take a look at the Honeywell T775P2003. 4 relay...

    Take a look at the Honeywell T775P2003. 4 relay outputs, can be config'd various ways 1st on 1st off, equal runtime...etc
  25. Replies
    10
    Views
    543

    Do you have the scale of the canvas pane set to...

    Do you have the scale of the canvas pane set to "fit ratio" ?
  26. Replies
    41
    Views
    2,302

    N4- Ready for prime time?

    Just wondering if anyone has successfully set up and implemented a N4 site yet. Either migrated AX or new.
  27. Replies
    4
    Views
    500

    What version?

    What version?
  28. Replies
    2
    Views
    369

    Yes. Sensor is wired to input 2 and input 2 is...

    Yes. Sensor is wired to input 2 and input 2 is configured as IAQ Sensor. Sensor is reading properly in IO Point tab. Ended up linking System Space IAQ from input 2 and point now reads properly as...
  29. Replies
    2
    Views
    369

    RTU_Open IAQ problem

    Have an issue where my Input 2 sensor which is configured for IAQ Sensor is not coming across on the BacNet point "iaq". Also not showing up on graphic.

    30 new RTU's using ZS sensors with CO2,...
  30. I replaced the CP controllers with lon Spyders....

    I replaced the CP controllers with lon Spyders. Replaced the CP jaces also.
  31. Rip them out or have owner call Corporate...

    Rip them out or have owner call Corporate Honeywell for service. Had to do same in a building recently.
  32. Replies
    18
    Views
    753

    most VFDs now have the ability to control of a...

    most VFDs now have the ability to control of a sensor. Call manufacturer tech support and you'll be done.
  33. They are really simple when you "get it". At...

    They are really simple when you "get it". At appx. 7-8 psi heat should be off and damper at minimum. On RA as space temp rises-pressure drops and damper should open to add cooling, as space temp...
  34. Wouldn't it be the opposite (RA). Temp...

    Wouldn't it be the opposite (RA). Temp drop=pressure increase. Also only 1 wire on your PE in last pic, not going to do anything
  35. Thread: Trane BCI-I

    by mechmike2
    Replies
    12
    Views
    1,666

    Thanks. I have done a lot of LCI-I's but first...

    Thanks. I have done a lot of LCI-I's but first BCI-I, is it OK to write programmatically to the set points? Also any preferred tuning policys?

    I'm also wondering if any of those other...
  36. Thread: Spyder Help

    by mechmike2
    Replies
    10
    Views
    880

    If you are on the config page of PID just hit...

    If you are on the config page of PID just hit help. You have to close config page to view.
  37. Thread: Trane BCI-I

    by mechmike2
    Replies
    12
    Views
    1,666

    How do you change the Out of Service property...

    How do you change the Out of Service property from false to true?

    Do I have to bring the point out twice? 1 for Present Value and 1 for Out of Service.

    Even after doing that cannot command...
  38. Replies
    1
    Views
    397

    Integrated about 30 meters using it around 2...

    Integrated about 30 meters using it around 2 years ago. Had issues and got them resolved through their tech support, can't recall what issue was but they were helpful.
  39. Replies
    10
    Views
    1,060

    As always check software manager to be sure...

    As always check software manager to be sure modules match up and upgrade if needed
  40. Replies
    10
    Views
    1,060

    You will have no problem commissioning, or...

    You will have no problem commissioning, or working in general, on a Vykon jace with Webs workbench.
  41. Replies
    3
    Views
    446

    Google Phoenix SRV-100. Thats what we used or a...

    Google Phoenix SRV-100. Thats what we used or a fairly large Bacnet integration. Phoenix Rep.had to set up the server and expose the points, was a pain in the ass getting them to show points I...
  42. Replies
    5
    Views
    1,023

    Strange thing happened recently when I used...

    Strange thing happened recently when I used station copier to change name of a site. After changing the name and rebooting when I opened the App. Director there were 2 stations on the Jace Old name...
  43. Replies
    6
    Views
    570

    add your email to profile and I'll send you some...

    add your email to profile and I'll send you some docs
  44. Replies
    44
    Views
    3,615

    The drive creates it own 24 VDC for the DI's

    The drive creates it own 24 VDC for the DI's
  45. Replies
    1
    Views
    492

    There are some decent graphics in the...

    There are some decent graphics in the kitPxGraphics module. You can put together a decent ERV, animated wheel included.
  46. Replies
    71
    Views
    11,281

    I am also wondering what device you are talking...

    I am also wondering what device you are talking about. It would be great to get what a Jace offers without having to pay licensing fees, upgrade fees, memory upgrade fees,...

    Shenanigans ??
  47. Replies
    71
    Views
    11,281

    What I love about Niagara is that I can bring in...

    What I love about Niagara is that I can bring in multiple devices talking different protocols and bring them in to one place and give the end user what they want. Nothing in life is cheap.
  48. Replies
    7
    Views
    1,371

    Part 1 Ductwork Part 2 Piping Part 3 Service...

    Part 1 Ductwork
    Part 2 Piping
    Part 3 Service
    Part 4 Realize I'm 40 and hate doing above.
  49. Replies
    1
    Views
    581

    Start/Stop loops in the 15c is how scheduling is...

    Start/Stop loops in the 15c is how scheduling is done. You would link schedule from the "A" to the Start/Stop loop, then use a Logic Loop to control a DO (FanEnable) off the Start/Stop.
  50. Thread: Btu

    by mechmike2
    Replies
    9
    Views
    1,145

    Love it.

    Love it.
Results 1 to 50 of 308