  1. Replies
    39
    Views
    800

    Lost my pro status to. Thanks

    Lost my pro status to.

    Thanks
  2. Thread: R404a Air Handler

    by stat
    Replies
    6
    Views
    585

    I'm guessing it's being tied to a rack.

    I'm guessing it's being tied to a rack.
  3. Replies
    48
    Views
    4,042

    In warm weather I clear the sight glass, no extra...

    In warm weather I clear the sight glass, no extra needed.
  4. At least the gas meter was conveniently located...

    At least the gas meter was conveniently located...
  5. Thread: Trace A Gas.

    by stat
    Replies
    9
    Views
    1,457

    How do you detect the leak if soap wont show it?

    How do you detect the leak if soap wont show it?
  6. 1 Galvanized is used for all other HVAC...

    1 Galvanized is used for all other HVAC applications I am aware of
    2 The thickness prevents failure in case of fire
    3 Raw black steel
    4 Yes to both. Anywhere an opening is being closed.

    I...
  7. Replies
    22
    Views
    2,131

    My last one went away two years ago when the...

    My last one went away two years ago when the place closed up.
  8. Thread: Drill collection

    by stat
    Replies
    27
    Views
    3,354

    yes

    yes
  9. Replies
    30
    Views
    4,392

    Yes we have worked for iim. We don't any more...

    Yes we have worked for iim.

    We don't any more though.

    They pay when and if they have time to get around to it.

    They never disputed a charge or that they owed the money, they just don't send...
  10. Replies
    20
    Views
    2,976

    Ran across a bad one last fall. Here is the note...

    Ran across a bad one last fall. Here is the note I made to myself to get it going until the replacement arrived:

    "Off on code C06 open start circuit. Removed "P" wire from controller and...
  11. Thread: Who's on call

    by stat
    Replies
    34
    Views
    2,406

    I'm on call this weekend. We have three service...

    I'm on call this weekend. We have three service guys so we make sure everyone only works one of the summer holidays.

    Hopefully we will have another guy by the end of the month so the rotation...
  12. Replies
    21
    Views
    6,233

    To the op, Did you get the hot side going?

    To the op,

    Did you get the hot side going?
  13. Replies
    37
    Views
    7,335

    +1

    +1
  14. Replies
    7
    Views
    1,063

    Trip charge. We are T&M. For flat rate I see...

    Trip charge. We are T&M. For flat rate I see how it could already be figured in and not listed separately.
  15. Replies
    7
    Views
    1,788

    To many times to remember...

    To many times to remember...
  16. Thread: Evap. goes where?

    by stat
    Replies
    16
    Views
    5,437

    Good dehumidification/reheat set up!

    Good dehumidification/reheat set up!
  17. Replies
    20
    Views
    3,393

    They may be running the condenser fan to cool...

    They may be running the condenser fan to cool things down even if the HP switch kills the contactor.
  18. Replies
    33
    Views
    5,845

    I set all me outdoor R22 units CI 10lbs and CO...

    I set all me outdoor R22 units CI 10lbs and CO 2lbs.
  19. SOG in my front pocket

    SOG in my front pocket
  20. Replies
    35
    Views
    4,458

    Fixed many condensers. Like others have said...

    Fixed many condensers. Like others have said Silphosing over the leak is first choice. I have spliced in a piece by sliding a piece of 1/2" over the tube sliding it back and pinching the ends down....
  21. Replies
    28
    Views
    3,553

    Nine years? Really? May be better to start a new...

    Nine years? Really? May be better to start a new thread...
  22. Replies
    29
    Views
    7,908

    I changed one similar to that a while back. The...

    I changed one similar to that a while back. The tenant says you just changed that two years ago, you should have done a better job. I say this what happens if you don't replace the filter. Tenant...
  23. Replies
    26
    Views
    4,600

    +1 on the Windows app.

    +1 on the Windows app.
  24. Replies
    18
    Views
    2,519

    Plenty of small stores and restaurants out there...

    Plenty of small stores and restaurants out there with refrigeration condensing units in the basement.
  25. Replies
    53
    Views
    5,382

    Is the condensing unit indoors or outdoors? If...

    Is the condensing unit indoors or outdoors? If indoors, follow icemeister's advice.
  26. Replies
    18
    Views
    2,519

    Are the evap and condenser in the same space? If...

    Are the evap and condenser in the same space? If not, and the bedroom is 3000sq ft it should work just fine.
  27. Thread: subcooling

    by stat
    Replies
    74
    Views
    9,315

    In other words, excessive subcooling makes the...

    In other words, excessive subcooling makes the TXV oversized.
  28. Replies
    53
    Views
    5,382

    Add a second receiver in series with the first. ...

    Add a second receiver in series with the first. Receivers are cheap. Cost about the same as the suction stop and you don't have to change how the system operates.
  29. Replies
    7
    Views
    1,113

    My reply to a similar query "The day I can...

    My reply to a similar query

    "The day I can see the future is the day I stop carrying tools for a living."
  30. Replies
    25
    Views
    2,623

    x2 The AC compressor in the store I service has...

    x2
    The AC compressor in the store I service has been out for two years..
  31. Kwik Trip?

    Kwik Trip?
  32. Replies
    41
    Views
    5,790

    There are three roof heights and two wheel bases....

    There are three roof heights and two wheel bases. The picture is of the standard height. I am interested in the medium height long wheel base which I believe is approximately 5'10" inside. Three...
  33. Replies
    41
    Views
    5,790

    Yes. I think it is what I want next. I want to...

    Yes. I think it is what I want next. I want to see one in person.
  34. Replies
    6
    Views
    720

    5%, 45% and staybrite

    5%, 45% and staybrite
  35. Replies
    71
    Views
    5,035

    So now you have a cap tube system with a receiver...

    So now you have a cap tube system with a receiver ?
  36. Replies
    71
    Views
    5,035

    Isn't that second condenser completely full of...

    Isn't that second condenser completely full of liquid?
  37. I just bought MB2 bag to use for trouble...

    I just bought MB2 bag to use for trouble shooting. I was wishing it was a little bigger.
  38. Replies
    29
    Views
    3,913

    In my jurisdiction the fire inspector will shut...

    In my jurisdiction the fire inspector will shut down a kitchen if the exhaust fans are found not to be working. The exhaust fans need to be running in case of fire. He will also require any cooking...
  39. Replies
    71
    Views
    5,035

    Condensing unit R404 TXV/receiver ETC ...

    Condensing unit
    R404
    TXV/receiver
    ETC

    Everybody wins
  40. Replies
    11
    Views
    2,761

    Suction line icing back on a freezer means...

    Suction line icing back on a freezer means nothing. On most of my systems ice on the suction line means everything is working properly. Make sure the evap is ice free, the box is close to temp and...
  41. Thread: Age old debate

    by stat
    Replies
    22
    Views
    2,611

    Been using Stay Brite for 25 years, including R22...

    Been using Stay Brite for 25 years, including R22 medium temp discharge lines. Never had an issue.
  42. Replies
    77
    Views
    10,277

    Around here the service dept of the restaurant...

    Around here the service dept of the restaurant supply company tells the customer it can't be fixed and the unit needs to be replaced.

    Actually, they do that to all equipment they look at. Keeps...
  43. Replies
    32
    Views
    4,297

    Just like the CPR, the pressure limiting TXV...

    Just like the CPR, the pressure limiting TXV prevents the compressor from excessive suction pressure, not flooding. Using the pressure limiting TXV saves you the cost of buying a CPR valve. This...
  44. Replies
    32
    Views
    4,297

    Never installed a condensing unit with an...

    Never installed a condensing unit with an accumulator in 25yrs, including the two low temps I put in last week. I have however seen systems with accumulators still flood compressors.

    Use a...
  45. Replies
    77
    Views
    10,277

    Anything made by Cold-Tech

    Anything made by Cold-Tech
  46. I trap the cooler at the coil, trap the freezer...

    I trap the cooler at the coil, trap the freezer line inside the cooler then tee into the common line
  47. Replies
    8
    Views
    26,085

    Make sure the cut in pressure saturated suction...

    Make sure the cut in pressure saturated suction temperature is below the coldest ambient temperature. Around here on R22 I use 8lbs CI and 2lbs CO. This will keep it running when it is -20F.
  48. Replies
    22
    Views
    3,738

    Screen roller tool

    Screen roller tool
  49. Replies
    23
    Views
    4,052

    I have worked out of a pick up for nearly 25...

    I have worked out of a pick up for nearly 25 years. Most of my trucks have had high side boxes and a gang box behind the cab. I did have a Reading cap once similar to the A.R.E and I liked that...
  50. Thread: Veto tool bags

    by stat
    Replies
    75
    Views
    17,336

    I Have been using a Tech LC for about a year and...

    I Have been using a Tech LC for about a year and it is hands down the best bag I have used. I now also have a Pro Pac. It is a lot easier to haul up a ladder than a shoulder bag, but I don't like...