    Niagara Alarm Instructions

    Within an alarm extension in Niagara you can add instructions to display in the alarm message. The editor for this field requires that you enter each line of instructions individually.

    First, is...
  2. My understanding is that everything that gets...

    My understanding is that everything that gets sucked into smartstruxure becomes a struxureware point. The field level devices are visible to you because you are bypassing the AS and talking directly...
  3. Replies
    1
    Views
    204

    Security Jace for BMS?

    I am trying to determine the pitfalls/general feasibility of using a security Jace to integrate to BMS systems and serve dual purposes. The jace would get a Trane Comm4 driver, a Redlink driver, and...
  4. Don't quote me on this, but I've been told that...

    Don't quote me on this, but I've been told that the Niagara Infinity driver will only work with a Netcontroller I. The Net II can't be interfaced using terminal mode.
  5. Help Displaying override status of Niagara point

    Hello all,

    I have a px view where I am displaying a bound label that the user can right click and select active, inactive, or auto to override the point. I would like the label to display the...
  6. Honeywell L2 universal Start/Stop Relay

    We do a fair amount of Honeywell retrofits where we come across these relays in their old panels. This is what they look like:

    14500580 relay

    The honeywell schematics show them being wired in...
  7. Replies
    22
    Views
    3,191

    I did consider that before posting, but after...

    I did consider that before posting, but after googling it and finding a previous AC256 thread on here with some of that info I went for it anyway. Any mods who feel that is sensitive info, feel free...
  8. Replies
    22
    Views
    3,191

    Ok, this is what I dug up from a page in the...

    Ok, this is what I dug up from a page in the notes I was given:

    "Beginning with a blank terminal screen...type in the correct device password. All AC256 passwords are six characters long and begin...
  9. Replies
    22
    Views
    3,191

    I don't have a lot of experience with the AC256...

    I don't have a lot of experience with the AC256 stuff, but I had a class on it a few weeks ago. One thing they mentioned is that the higher your baud rate is set for the reload, it is more likely...
  10. Replies
    35
    Views
    4,948

    Sounds like a trap issue to me. My guess would...

    Sounds like a trap issue to me. My guess would be possibly a damaged or stuck riser trap somewhere, but we would need more information about your system layout to diagnose it.
  11. I'm not sure I understand your question, but is...

    I'm not sure I understand your question, but is it as simple as writing a program in plain english?

    For example:
    If(discharge air temp)>(setpoint) then (Damper)=On(or-On depending on polarity).
    ...