  1. You assume right!!!

    You assume right!!!
  2. Replies
    7
    Views
    209

    Sounds like your units are in the basement and...

    Sounds like your units are in the basement and the return air is taking the path of least resistance and being sucked into basement I s that right
    With Radon concerns, the last thing you want is a...
  3. Shophound nailed the "usual suspects" but I...

    Shophound nailed the "usual suspects" but I think you have a new BOX with a deficient duct system. You are just not delivery what you need to where you need it
  4. Replies
    8
    Views
    221

    Our neighbors to the North have a reputation for...

    Our neighbors to the North have a reputation for building tight homes! Do you have an ERV? Did they do a blower door? If you have the required Insulation ( are you sure there isn't rigid...
  5. Replies
    23
    Views
    672

    In general, You have replaced the existing "BOX"...

    In general, You have replaced the existing "BOX" with a (potentially) more efficient BOX but that is only a third of the SYSTEM! the other elements are the duct system and as Energy Rater will tell...
  6. Where did you get this clearance information?...

    Where did you get this clearance information? Source ? recomended or required?

    You posted
  7. About the ALLAH prayer comment I would like to...

    About the ALLAH prayer comment I would like to suggest that one of the more famous people who was born, lived and dies as a JEW was CHRIST! Show me where he said he was changing religions. It was...
  8. Like a lot of you have said, I don't care what...

    Like a lot of you have said, I don't care what consenting adults do or what their hobbies are. If it's tolorance the Gay community is looking for, you got it BUT it seems that it's an endorsement...
  9. Replies
    2
    Views
    531

    Highlight my name and use contact info. ...

    Highlight my name and use contact info. Explanation too long for back and forth posts
  10. Let me understand this You have chilled water...

    Let me understand this You have chilled water and the designer didn't select a coil, deep enough to remove the latent ( RH) load and you have to either pre heat or re heat the air? HMMMM...
  11. Regardless of the units that we use, the main...

    Regardless of the units that we use, the main advantage of ductboard is the low leakage compared with standard sheet metal duct, You are sizing your duct based on your fan, so you'll need to get...
  12. Replies
    10
    Views
    2,001

    The answer to your question is: The air needs a...

    The answer to your question is: The air needs a low resistance path to get back to the unit, and undercut 3/4" clear space under the door is good for about 80 CFMs so use Darrells "jump duct" advice...
  13. Replies
    4
    Views
    1,422

    Hey Mr Bill, long time no hear, I sometimes go...

    Hey Mr Bill, long time no hear, I sometimes go into "remission" with posts but to answer your question How about if the unit was horizontal, you know those typical "economy" jobs with just a...
  14. You may first want to ask yourself, Why is this...

    You may first want to ask yourself, Why is this unit removing thrheat but not the humidity? Is the charge right? probably or you wouldn't cool Is the airhandler set at 350 CFMs per ton for that...
  15. Replies
    4
    Views
    1,422

    Darrell, there are a couple of "old BEST...

    Darrell, there are a couple of "old BEST PRACTICES" that are not really based in fact or engineering, like within 6 or 12 inches of the end of a duct OR as you mentioned: the endcap OR the top of...
  16. Replies
    3
    Views
    1,496

    If the customer did a similar thing to you as an...

    If the customer did a similar thing to you as an auto mechanic, how would you feel about the situation?
  17. Replies
    13
    Views
    803

    If the duct ( other than you concerns about too...

    If the duct ( other than you concerns about too big) is sound and will carry the air THEN BIGGER IS BETTER!!!!

    Bigger duct means lower velocity, which means less fan horse power.

    Same...
  18. Replies
    6
    Views
    728

    Seems like your main concern is winter (you...

    Seems like your main concern is winter (you probably don't see much summer load) and therefore you may want to check indoor pressure WRT (with reference to) the outside, keeping inside slightly...
  19. You do understand, that unless the intake of...

    You do understand, that unless the intake of that exhaust is very close to the source of the soldering fumes, that it is going to have very little effect on the air quality!

    Industrial exhaust...
  20. Great answer! every time you "start-up" the unit...

    Great answer! every time you "start-up" the unit and reduce the indoor temp and RH , there is the possibility and in Miami, the probability of sweating duct!
    Thing is, bare duct is going to be...
  21. I agree with beenthere, it's all about...

    I agree with beenthere, it's all about usuage,recovery rate/ storage with the complication of a better rate for off-peak. Although I don't see where on peak usuage would trip, or get close to 80%...
  22. The added 8" duct will reduce the overall...

    The added 8" duct will reduce the overall resistance of t6he duct system and therefore you should get more CFMs with the lower Available Static Pressure
    Which enc you put the exhaust fan will...
  23. Replies
    2
    Views
    587

    How about just an outside air louver, low and...

    How about just an outside air louver, low and through the wall to equalize the pressure diff? if there isn't a concern about freezing ( you said seasonal) then you don't even need a damper to seal...
  24. Replies
    8
    Views
    445

    You're right George, too many contractors go...

    You're right George, too many contractors go broke because they didn't know their cost.
    But you'll agree (I believe) that one of those cost is the Sales cost of the SG&A and just as important HOW...
  25. Replies
    12
    Views
    794

    Clearly you are "fiber-phobic" and therefore...

    Clearly you are "fiber-phobic" and therefore Dan's reference below"



    Is really timely! All concerns about "fibers in the airstream has been put aside when the Govt accepted ( 9 years later) ...
  26. Replies
    26
    Views
    1,443

    Point is, So I would harbor any bad felings for...

    Point is, So I would harbor any bad felings for what you didn't know and therefore didn't tell them and then they didn't know either!
  27. Replies
    12
    Views
    428

    I share Dan's concerns PLUS I would like to...

    I share Dan's concerns PLUS I would like to mention the much higher First Cost and the Much higher Repair cost and limited number of people who can service the more complicated unit
    The owning cost...
  28. NO you are not nitpicking, but you are showing...

    NO you are not nitpicking, but you are showing off! Clearly you know the proper procedures, so I wonder why you even posted this?

    You asked the question, I thought I would say out loud what I...
  29. Replies
    8
    Views
    445

    Let's see: You came recommended by your mutual...

    Let's see: You came recommended by your mutual friend/ acquaintance, the contractor got the lead with no sales marketing cost, you were described as a reasonable / low maintenance,/ business owner...
  30. Replies
    9
    Views
    1,832

    Teddy bear, it's my understanding that you need...

    Teddy bear, it's my understanding that you need organic material (dirt) AND LIQUID WATER to row "bugs"
    After all the place where the highest RH found is at the discharge of the AC unit

    Does that...
  31. Replies
    9
    Views
    556

    Do you insulate then cut and mount take offs? ...

    Do you insulate then cut and mount take offs? Sounds better than next Mount take offs then insulate?

    Do you double insulate attic ducts? Bad idea to have a double vapor barrier that would...
  32. You Guys clearly got the skinney on this poster, ...

    You Guys clearly got the skinney on this poster, I give up and will go quietly

    Thing is the answer to his question is of no value to a DIY except to make clear that the "civilian" is not going to...
  33. Yes, increasing the motor speed will require more...

    Yes, increasing the motor speed will require more energy, but a small amount compared with running the unit longer to get the troubled area to temp while over-cooling the other spaces
    Increase...
  34. Replies
    7
    Views
    404

    I think you answered your own question

    I think you answered your own question
  35. Point taken, Of course if this tech is the...

    Point taken,
    Of course if this tech is the kind of person who takes pride and possession of the work he does, than that could explain the "my" part

    Don't you agree that we didn't and couldn't...
  36. Clearly you are not from US Ductboard is tested...

    Clearly you are not from US
    Ductboard is tested to 2.5 times listed velocity and no erosion, so at 2500 FPM which is 3X what you would normally see in typical residential designs, velocity is not...
  37. Replies
    26
    Views
    1,443

    beshvac is right! you don't have a sealed crawl...

    beshvac is right! you don't have a sealed crawl space, you have an indoor swimming pool!!!!!

    If cost is a factor, you may want to insist that the w3ell meaning HVAC Contractor who didn't...
  38. I think you all are misunderstanding this guy, ...

    I think you all are misunderstanding this guy, who is most likely in the biz, not one of the approved or a DIY who has a non US piece of equipment and was looking for an answer that has nothing to...
  39. Replies
    3
    Views
    400

    I thought the big problem was not having enough...

    I thought the big problem was not having enough capacity for the connected load? Wonder why you couldn't just use a smaller nozel if you think the "overfire" was too high?
  40. I think the Non Chemical / JM reference was made...

    I think the Non Chemical / JM reference was made to do exactly what has happened....You asked the question Chemical what?
    I think JM is calling your attention to the potentially bad fire...
  41. Replies
    25
    Views
    2,114

    The connector vs duct issue is a matter of the...

    The connector vs duct issue is a matter of the flex passing 1 or 2 additional tests like flame penetration (I think) almost all the manufacturers have gone to the DUCT classification but consider the...
  42. George has it right! The return has top be large...

    George has it right! The return has top be large enough to provide a low resistance path back to the unit And a brilliantly placed return grill (location( will not make up for not enough or properly...
  43. If Nat Gas is aviliable and the Utility doesn't...

    If Nat Gas is aviliable and the Utility doesn't discount Heat Pump use any longer than 90% Gas Furnace best bet. You can hedge your bet somewat by installing a heat pump split instead of just a...
  44. If your unit is charged and running properly then...

    If your unit is charged and running properly then Seems like you may have a problem with the quality of the home itself...... Get a blower door test top see how much infiltratration you have Then...
  45. Replies
    5
    Views
    334

    Your Gravity duct system worked with gravity...

    Your Gravity duct system worked with gravity because it was low resistance / oversized!! That means it had next to no real pressure and a lot of surface area that makes Energy rater's advice about...
  46. Me thinks that you may not be as comfortable as...

    Me thinks that you may not be as comfortable as you would like AND you may have concluded that the location of the diffuser is the reason for the situation. You first need to figure out if you are...
  47. Replies
    14
    Views
    1,318

    The idea is to get the right amount of air to the...

    The idea is to get the right amount of air to the space that does the job.
    If you don't have airflow problems and just don't like the "look " of the standard registers than that is just a...
  48. Replies
    39
    Views
    2,832

    Redundant and oversized? There are enough...

    Redundant and oversized? There are enough safeguards in the design calcs to handle this. Oversizing will not only increase cost but also may not remove humidity as well as a right sized or even a...
  49. Thread: Hrv yes or no

    by genduct
    Replies
    3
    Views
    566

    Without a blower door test to MEASURE...

    Without a blower door test to MEASURE Infiltration, and how effective your insulation job is, you can only Guess
    My engineer Son has a 9x11 poster that says " Without the DATA you are just someone...
  50. Replies
    7
    Views
    707

    Hey Energy! I am suprised you didn't suggest...

    Hey Energy! I am suprised you didn't suggest they just fill the whole space up with closed foam and call it a day
    Mike