Search:

Type: Posts; User: sycontrol

Page 1 of 7 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    32
    Views
    1,444

    Matrix. Not disagreeing with what you said. ...

    Matrix. Not disagreeing with what you said. Just trying to understand.

    So if I put one controller and connect it to two JACE all would be OK?
  2. That's the same symptoms I had. I was like half...

    That's the same symptoms I had. I was like half the program was running but other parts were not. A brief power glitch will sometimes cause the controller not to reboot at all or not properly. I...
  3. What capacity are you at with the program size? ...

    What capacity are you at with the program size? I have had this happen with controllers that were at or pushing max recommended capacity. If you are much over 85% capacity then that is most likely...
  4. I'm not much on the mechanical side but most...

    I'm not much on the mechanical side but most Trane units have a set of contacts where you can cycle it thru test mode. All the compressors will fire, fans on and heat if it's set up. You have to...
  5. Depends on the type of unit and how Trane has it...

    Depends on the type of unit and how Trane has it setup. Looks as though Type A is space temp control. Make sure your occ and unocc setpoints are in the correct order. Looks like Type B is doing...
  6. Replies
    32
    Views
    1,444

    Hooking the FX 60 to the device probably wasn't...

    Hooking the FX 60 to the device probably wasn't the best of ideas. LON can only have one managing device. In this case it was the NAE. If you did a replace on the controllers on the FX 70 now it is...
  7. Replies
    32
    Views
    1,444

    Authentication key is under lon netmgmt. Right...

    Authentication key is under lon netmgmt. Right click the lon network and select properties. Expand Lon Netmgmt. Authenticate should be set to false. Authentication key on mine is all FF FF FF FF...
  8. Replies
    14
    Views
    546

    What's the busy time in your JACE? What type of...

    What's the busy time in your JACE? What type of bindings did you setup Normal, Reliable, Critical (that's from memory may have left some out). Reliable and Critical will have a lot more traffic. Is...
  9. Replies
    3
    Views
    297

    I had a similar issue. I ended up using open...

    I had a similar issue. I ended up using open relay. It uses the IP address of the JACE to authenticate on the mail server so you don't need a user name or password. Works great and no password...
  10. Replies
    5
    Views
    361

    You also have to taggle the out of service points...

    You also have to taggle the out of service points for the particular points you want to control via the BAS.

    From the Trane Document:

    You can define the amount of control that the BAS system...
  11. Replies
    11
    Views
    765

    If you have a JAR file loaded on a JACE that is...

    If you have a JAR file loaded on a JACE that is not in the modules folder of that installation then the software manager will tell you that it is not available locally. If you are 100% certain that...
  12. Replies
    14
    Views
    546

    If there are any LON bindings that would be a...

    If there are any LON bindings that would be a good thing to know. Not sure how to find that out in an NAE but you would look at the LON network wire sheet of a JACE. Do not recommission any of the...
  13. Replies
    3
    Views
    309

    there is an example on the JCI whatspossible...

    there is an example on the JCI whatspossible website of using these. I think Greg Wilmer posted it.
  14. Replies
    10
    Views
    672

    Awesome. Thanks!

    Awesome. Thanks!
  15. Replies
    10
    Views
    672

    AWESOME! I will say after talking to 3...

    AWESOME!

    I will say after talking to 3 different schneider electric folks in different states and two 888 numbers later.....I still have no one that can or will help me. Software would be GREAT!...
  16. Replies
    10
    Views
    672

    While our service tech was there I had him look...

    While our service tech was there I had him look at the lights. The yellow (rx) light was blinking rapidly like it was getting data. The green Tx light was blinking like once a second or maybe...
  17. Replies
    10
    Views
    672

    PEM 1 Controller

    I am supposed to look at a PEM 1 controller tomorrow. I know it has an ASD bus but is this proprietary to Invensys? Is there any software that I can use to look at the controller?

    It seems this...
  18. Replies
    7
    Views
    325

    You see the entire network using Rover? Go to the...

    You see the entire network using Rover? Go to the Lon Utilities Manager in the JACE. Set the command to Identify and set the SubCommand to Service Pin and press Execute. Go to any lon controller...
  19. Replies
    11
    Views
    938

    Yellow means the device is down. Orange meas the...

    Yellow means the device is down. Orange meas the device or point is in a fault condition. Either way you are not communicating with the units/points that are in this color. If they "blink" in and...
  20. Replies
    11
    Views
    938

    I would have a look at the bacnet device manager....

    I would have a look at the bacnet device manager. See if the problem units are in yellow which could indicate a communication issue. Also, sometimes a JACE reboot will clear up some things,...
  21. Replies
    11
    Views
    371

    While I agree 100% that it is TAB's function to...

    While I agree 100% that it is TAB's function to enter this data into the boxes, I am stuck doing this most of the time for TAB. Last job I sat for two days and opened boxes to max/min flow and input...
  22. Replies
    11
    Views
    371

    I see that point scrool. So if the balancer...

    I see that point scrool. So if the balancer tells me the box is flowing 300 cfm and the box is reporting 210 cfm how do I know what value to make the gain?
  23. Replies
    11
    Views
    371

    They do show up. The has to be a point somewhere...

    They do show up. The has to be a point somewhere to enter the actual flow readings from a flow hood so the box can calibrate itself and adjust the K factor. So if the box is reporting 340 cfm and...
  24. Replies
    11
    Views
    371

    I looked for it on trane website but didn't see...

    I looked for it on trane website but didn't see it.
  25. Replies
    11
    Views
    371

    UC 400 VAV Balancing in Niagara

    I've got some new Trane VAV boxes with the UC 400 controller in them. I've got the Tracer TU Balancing guide but I don't have Tracer TU. I've found most of the points that TU talks about but I...
  26. Replies
    13
    Views
    1,100

    Very nice. I've tried sketch up, GIMP and...

    Very nice. I've tried sketch up, GIMP and Blender. I struggle, bad just to make a straight line lol.
  27. Replies
    3
    Views
    361

    I do not think slot 8 is a writable slot in a...

    I do not think slot 8 is a writable slot in a JACE. If you look at any writable point in the FX 60 you will notice that slot 8 does not have the 2 arrows pointing down at the end of the slot.
  28. Replies
    13
    Views
    470

    Rover 7.1 did allow me to change the discovery...

    Rover 7.1 did allow me to change the discovery domain and I found all the devices. I was able to set the change the limits on the cooling min/max value to allow the cooling setpoint to change.
    ...
  29. Replies
    5
    Views
    267

    That's the part that's got me confused. The flow...

    That's the part that's got me confused. The flow setpoint is 400 cfm. The flow sensor is reading 0 cfm. The damper is closed and the damper output from the controller is calling for 0% damper. ...
  30. Replies
    5
    Views
    267

    I found this on this site as well. Maybe my...

    I found this on this site as well. Maybe my issues is similar, but there are about 60 other VV550's working fine.
    ...
  31. Look at the Facility Explorer group...

    Look at the Facility Explorer group
  32. Replies
    5
    Views
    267

    Trane VV550 Damper issue

    I'm working with some Trane VV550's and I've got 2 that have me scratching me head. It seems the damper will not open. The have an flow setpoint, duct in temp across the network seems fine. There...
  33. if you look at the whatspossible jci website...

    if you look at the whatspossible jci website there is a lot discussion about this topic. Seem if you have custom modules in a pre PCT 10 caf file they won't be in the caf file when you open it with...
  34. Replies
    11
    Views
    485

    In serial shell mode you should have an option to...

    In serial shell mode you should have an option to reset the passwords back to default. You could also use FTP and something like filezilla to transfer the license to the JACE. Just enable FTP from...
  35. Replies
    4
    Views
    346

    I've only done it one time. I've worked with...

    I've only done it one time. I've worked with others though. If there is no supervisor on the network you should be ok to put a JACE on it and do a quick learn. This will learn the bindings if there...
  36. Replies
    4
    Views
    346

    Is the network currently managed? As long as you...

    Is the network currently managed? As long as you don't recommission the controller the bindings should stay. If you are only wanting data make sure to get only nvo or hardware points. It's...
  37. Replies
    13
    Views
    470

    Thanks Will!

    Thanks Will!
  38. Replies
    13
    Views
    470

    I'm using Rover version 6. I pushed the service...

    I'm using Rover version 6. I pushed the service pin and with rover in passive mode it did show in the discover window. It never prompted me to change to that network and I do not see where to...
  39. Replies
    13
    Views
    470

    Doing this won't affect my devices working with...

    Doing this won't affect my devices working with my JACE right? Just making sure that the changes occurs in Rover and Rover is not changing my devices.
  40. Replies
    13
    Views
    470

    thank you very much for the info.

    thank you very much for the info.
  41. Replies
    13
    Views
    470

    When you say setpoint limits I'm not sure I...

    When you say setpoint limits I'm not sure I follow you. I hooked Rover back up today but for some reason none of the controllers would discover. I don't know why. It worked before I put the JACE up...
  42. Replies
    13
    Views
    470

    Trane VV550 Effective Setpoint

    I'm almost done with an integration of pulling some Trane controls into a JACE. I've worked with the VV550 before and I've came across something that has kinda stumped me. In the VV550 installation...
  43. Thanks. I did bind the new links. Are there any...

    Thanks. I did bind the new links. Are there any times when you would not bind a new link in the lon link manager.
  44. LON bindings vs Wiresheet of Lon Network

    I'm having a hard time in my archives to recall something. If I got to the Lon network wiresheet of a JACE and make a connection from an nvo to an nvi do I also have to go to the lon link manager...
  45. Replies
    15
    Views
    873

    Thanks for the reply. There are no termination...

    Thanks for the reply. There are no termination resistors in the link that I can find. I have found the first device in the loop and there is no termination resistor there. This makes me think if...
  46. Replies
    15
    Views
    873

    Thanks for the reply Scroolose! So if there is...

    Thanks for the reply Scroolose! So if there is and where the repeater may be is anyone's guess without some as built drawings. Oh boy, this could be fun. The wire is Echelon Level 4 22/2...
  47. Replies
    15
    Views
    873

    Trane Lon to AX

    I'm pulling about 100 devices (LCI-I, MP503,VV550, ZN517) into a JACE. It is currently running on a BMTX BCU at revision D. Trace summit is rev 17. I do not see any repeaters in the BCU which...
  48. Replies
    5
    Views
    262

    Your welcome! Glad I could help!

    Your welcome! Glad I could help!
  49. Replies
    5
    Views
    262

    I just fixed this in one of my stations today...

    I just fixed this in one of my stations today 3.7.106

    In workbench (I'm using JCI) go to tools options then alarm console. Look about half way down and change Time Zone Display to Source. That...
  50. Replies
    1
    Views
    139

    I fixed it. I was using px in my file name at the...

    I fixed it. I was using px in my file name at the end like ChillerIncludesPx.px. I guess it didn't like using px in the file name. I removed that and it worked.
Results 1 to 50 of 314
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event