  1. Replies
    13
    Views
    1,316

    definately a possibility... good call. would...

    definately a possibility... good call.

    would you say in the condensor on the cold liquid line unit, and in the liquid line or at the orifice with the high head unit?
  2. Replies
    13
    Views
    1,316

    i have never seen anything like it. as far as the...

    i have never seen anything like it. as far as the superheat goes, the wetbulb in the house was 68 deg, and the psi at the suction relating to a 30 deg coil, and the suction 45 deg temp at condensor....
  3. Replies
    13
    Views
    1,316

    internal bypass

    here in chicago, it's 102 degrees. all of a sudden we get flooded with internal bypass problems on a bunch of resi units. mostly 10 seer. some just need the coils cleaned or acid washed, but some...
  4. Replies
    11
    Views
    4,271

    amp out condenser fan motor. acid wash cond....

    amp out condenser fan motor. acid wash cond. coil. then check and adjust charge to proper superheat using a superheat charge sliding chart or the ruud recommendations (if available). 15 to 20sh...
  5. Replies
    17
    Views
    1,784

    check for bad valves by pumping sytem down to...

    check for bad valves by pumping sytem down to check suction valves.
    then if it pumps down, open high side back up and block the cond coil with cardboard.(high side should rise in pressure if high...
  6. Thread: help....

    by aceinstaller
    Replies
    50
    Views
    3,091

    my email should be in my profile. construction...

    my email should be in my profile.

    construction knowledge is a plus because we also remodel homes in slow periods.

    email me a resume, and leave contact info. I'll give you a link to our...
  7. Thread: help....

    by aceinstaller
    Replies
    50
    Views
    3,091

    ccarney, I may be able to take on an...

    ccarney,

    I may be able to take on an apprentice.:cool:

    what do you think about dupage county?

    hands on training is the best training.

    comm/resid hvacr
  8. Replies
    18
    Views
    1,443

    check the power to the coils and make sure it's...

    check the power to the coils and make sure it's within tolerances. also ensure good unit and secondary grounds.
    I've had this problem before with other rtus.
  9. Replies
    8
    Views
    776

    thanx for the replies:) i'll ask about...

    thanx for the replies:)

    i'll ask about commercial motors.

    ace
  10. Replies
    11
    Views
    1,073

    when the refrigerant is recovered and the lines...

    when the refrigerant is recovered and the lines are open to replace filter drier, cut the suction line in a spot where it would be easy to braze a coupling. purge nitrogen into the suction while...
  11. Replies
    8
    Views
    776

    replacement cond. fan motors

    Why must everything be built like junk nowadays?

    anyone else have problems with all of the new cond. fan motors in the larger older styled equipment?

    I have some custies with older equiptment...
  12. Replies
    11
    Views
    1,073

    why not replace the drier, clean the orifice, and...

    why not replace the drier, clean the orifice, and flush lines with nitrogen? if in fact it is a restriction after you thaw the ice.

    I have more problems with txv valves than orifice systems. ...
  13. Replies
    66
    Views
    6,012

    after rereading your post green ears, in your...

    after rereading your post green ears,

    in your case, you had a restriction in a total different spot.

    your restriction was in the filter drier, and that is before your metering device.

    you...
  14. Replies
    66
    Views
    6,012

    hey greenears, when we say "condense" we are...

    hey greenears,

    when we say "condense" we are referring to taking a GAS and compressing it into a LIQUID. this action does a few things: builds pressure, and the byproduct is heat. removing the...
  15. let's just skip the email and list the goods!:D ...

    let's just skip the email and list the goods!:D

    if we like em we'll drop by to take a look.

    looking for common replacement parts. it's too hard to store uncommon compressors or boxes.
  16. Replies
    5
    Views
    639

    belt drives require seasonal maint.

    see title
  17. clean coil, and clean ducts

    I run into this all of the time. coils in homes will get plugged up from time to time due to lack of filter maint., or dirt bypassing filters. the mold can form on the buildup of dirt, due to the...
  18. Replies
    33
    Views
    17,012

    I asked the guy at the supply house the other...

    I asked the guy at the supply house the other day, why doesn't the manufacturer post the running load amps on the compressors anymore?

    he stated that too many dorks were going around charging...
  19. Replies
    9
    Views
    823

    whenever inside a customers home with undersized...

    whenever inside a customers home with undersized ductwork, you will always see a recommendation for for repairs on our invoices. as well as recommendation for less restrictive filters.

    But,...
  20. Replies
    17
    Views
    1,217

    Nice concept addfreon, of course this extra...

    Nice concept addfreon,

    of course this extra charge will be billable to the customer by the hour for the conversation, correct?

    Ace
  21. Replies
    38
    Views
    1,994

    thanks for the input guys, it's nice to see some...

    thanks for the input guys, it's nice to see some other opinions to reflect.

    I totally agree with you, although I did in fact give him a discount on the service call......

    he had the balls to...
  22. Replies
    38
    Views
    1,994

    What is with these customers that tell you what...

    What is with these customers that tell you what would be fair for repairing their equiptment?

    so lets say that you talk to the customer on the phone and explain the price for diagnosing the unit...
  23. good compnies can be found by referral If you...

    good compnies can be found by referral

    If you think that you are going to make the rates, the a good company will not even come to your home.

    in the service industry we "typically" work on a...
  24. Replies
    7
    Views
    1,404

    what is a jci control?

    what is a jci control?
  25. Replies
    130
    Views
    10,646

    I agree with the fact that spying on techs is...

    I agree with the fact that spying on techs is rude when a boss shows up to be a nusance, but this is the service industry, and it is impossible for the boss to know the troubleshooting skills of...
Results 1 to 25 of 90