  1. Replies
    17
    Views
    1,329

    Helical and has ben working properly oil...

    Helical and has ben working properly oil teservoir never been lower than 1 st sight glass. Oil floats on all compressora at a half sight glass
  2. Replies
    17
    Views
    1,329

    ee

    Suction pressures bumped up 56# and 15# going though every coil superheat and all r sheets being revised traps on all coils .
  3. Replies
    17
    Views
    1,329

    It wouldseem floodback none visible nor are the...

    It wouldseem floodback none visible nor are the temp readings from suction trunks showing floodback temps at any point. Piping is all correct per r sheets stumped
  4. Replies
    17
    Views
    1,329

    Breakin rods, locking up all compressors have...

    Breakin rods, locking up all compressors have been replaced atleast 10 according to log books rack is four years old evaps are still original.graphs show no floodback records show people have...
  5. Replies
    17
    Views
    1,329

    rack breaking compressors

    We picked up new account today its a food processing plant 8 copeland compressors mt and lt rack common discharge seperate suctions accumalator on lt compressors. Mt suction running 42# lt at 8# ...
  6. Sticky: Yea the asap aspect of markets is very true....

    Yea the asap aspect of markets is very true. Thats another reason i like markets they understsnd the urgency of the repair so approvals are quick.
  7. Sticky: Today i got to change an oil seperator. It had a...

    Today i got to change an oil seperator. It had a turboshed and we determined it wasnt feeding all compressors off on oil failure no oil or pressure coming from the oil supply line. Couldnt be cleaned...
  8. Sticky: I began taking hvac classes at a community...

    I began taking hvac classes at a community college and found refrigeration a bit more interesting . I met a guy in class who worked in the field and i was lucky enough to get a job there. It was a...
  9. Replies
    25
    Views
    2,620

    Ive used acid away on every burn out job...

    Ive used acid away on every burn out job haventhad a call back since on any.
  10. Replies
    13
    Views
    1,027

    I would recommend valve plate check and if this...

    I would recommend valve plate check and if this is a discus its hard to see a bad valve plate load compressor up fully and bench check run into vacuum i like to see atleast10 in vac and hold
  11. Replies
    13
    Views
    1,139

    Ive seen it on a costco rack which was scroll to...

    Ive seen it on a costco rack which was scroll to carlyle and from watching it run it fills with liwuid andeven oil when it fills second sight glass it opens line to flow to discharge header. Im...