  1. Replies
    20
    Views
    2,191

    It's a 3 ton heat pump. The basement is 30x15, 8...

    It's a 3 ton heat pump. The basement is 30x15, 8 feet high.
  2. Replies
    32
    Views
    4,507

    See if the unit has split coils, some even are 3...

    See if the unit has split coils, some even are 3 rows deep. Can't recall any intellipacks having 3 rows but make sure.
  3. Replies
    20
    Views
    2,191

    Cool whip your from s.e. mich? Who doyou work fo...

    Cool whip your from s.e. mich? Who doyou work fo r?
  4. Replies
    20
    Views
    2,191

    What do you guys think?

    The salesman wants me to install a condenser in the basement of a commercial building. No air flow, no windows, no make up air???? I think he's nuts. Oh and it's a heat pump. I'm just venting...
  5. Replies
    3
    Views
    1,273

    It could be any of those problems you mentioned....

    It could be any of those problems you mentioned. It might be time to call in a pro before you end up being the power head for the valve... all winter long
  6. Replies
    12
    Views
    2,240

    Must have been lowest bidder.

    Must have been lowest bidder.
  7. Replies
    26
    Views
    1,788

    A fan cycler should be used when the compressor...

    A fan cycler should be used when the compressor will run in low ambient conditions to keep the saturation temperature in the condenser up.
  8. Thread: On call pay

    by toptwo
    Replies
    82
    Views
    19,609

    We get 1 hour a day for everyday were on call....

    We get 1 hour a day for everyday were on call. Thats at regular pay, then if we get called out we get 1.5 time for after hours and double time on Sunday. thats the unions rule.
  9. Replies
    4
    Views
    441

    I agree with milk-man you should call in a pro...

    I agree with milk-man you should call in a pro now, before you have to call one on the weekend.
  10. Thread: Steamer issue

    by toptwo
    Replies
    6
    Views
    560

    Steamer issue

    Which stat would you guys recommened for steam boiler. I would like one that i can set up the anticipator. The pressure switch seams like its working fine when the pipes are cold but when pipes are...
  11. Replies
    17
    Views
    1,187

    Same.

    Same.
  12. Replies
    17
    Views
    1,187

    Duplicate and No *.

    Duplicate and No *.
  13. Thread: membership

    by toptwo
    Replies
    1
    Views
    388

    membership

    Where do I go to become a pro member?
  14. Thread: heat pump help

    by toptwo
    Replies
    6
    Views
    509

    Ok I'm going pro

    Ok I'm going pro
  15. Thread: heat pump help

    by toptwo
    Replies
    6
    Views
    509

    I'm not a diy, never really looked into becoming...

    I'm not a diy, never really looked into becoming a pro member. Fyi I have been service tech for 10 years, and dont do much residential and have only worked on a heat pump 1 or 2 times.
  16. Replies
    39
    Views
    4,754

    Hartford, YES

    Hartford, YES
  17. Thread: heat pump help

    by toptwo
    Replies
    6
    Views
    509

    heat pump help

    Heat pump help, I'm trying to walk my buddy thru wiring a heat pump over the phone. It's a 2 stage Ruud furnace with a heat pump outdoors air/air.
    I'm not a heat pump gut but I told him that the...
  18. Replies
    17
    Views
    1,242

    It was under warranty, and it's a buddies house...

    It was under warranty, and it's a buddies house so for some good food and laughs it was worth it
  19. Replies
    17
    Views
    1,242

    It was under warrenty, and it's a buddies house...

    It was under warrenty, and it's a buddies house so for some good food and laughs it was worth it.
  20. Replies
    17
    Views
    1,242

    It is an Arcoaire model: NUG, 100,000 btu 90% ...

    It is an Arcoaire model: NUG, 100,000 btu 90%
    It took me almost 6 hrs with stopping every 10-15 minutes and talking with the homeowner. Now I remember why I dont care for residential work that...
  21. Replies
    17
    Views
    1,242

    Heat Exch.. change out time

    How long should it take to change out a primary and secondary heat exchanger in a residential unit?
  22. Replies
    30
    Views
    9,422

    You may as well get a bid to zone the basement...

    You may as well get a bid to zone the basement and main floor while your at it. Also dont let the size of equipment choose you/ each manufacture has different sizes you choose the one thats right for...
  23. Replies
    17
    Views
    1,873

    I dont think its a resriction with that back...

    I dont think its a resriction with that back pressure, check your coil for dirt????
  24. Replies
    12
    Views
    8,209

    How about an AUX switch.

    How about an AUX switch.
  25. Replies
    13
    Views
    1,051

    REALLY????

    REALLY????
  26. Replies
    7
    Views
    1,665

    The oil pressure safety is reading crank pressure...

    The oil pressure safety is reading crank pressure not net oil pressure. Thats why its tripping the oil safety (I think), Also you should see if this has a pump down system in place if it does not try...
  27. Replies
    7
    Views
    1,665

    Pull the head and look at the top of the piston,...

    Pull the head and look at the top of the piston, it might be twisted.
  28. Replies
    105
    Views
    8,249

    See if the tech can check the compressor, to see...

    See if the tech can check the compressor, to see if it is pumping to capacity.
  29. Thread: Micron gauge

    by toptwo
    Replies
    19
    Views
    3,080

    You may want to poor some rubbing alcohol in the...

    You may want to poor some rubbing alcohol in the connection ports to clean the sensor off of the VG64 and let it dry before using again.
  30. If you are calling it "FREON" you need to call...

    If you are calling it "FREON" you need to call someone, and pay for their services before you get frost bite on your fingers.
  31. Replies
    27
    Views
    4,482

    unloaders 06E compressor

    When is the best time to set the unloaders? I'm working on a 06E compressor
    with 2 heads that unload (mechanical unloaders). I've heard it two ways with a lot of load and with little load. What do...
  32. Replies
    17
    Views
    1,562

    You need a TXV to throttle the refrigerant....

    You need a TXV to throttle the refrigerant. Unless you bought less than a new 13 seer condensor.?
  33. Thread: armstrong txv

    by toptwo
    Replies
    11
    Views
    1,951

    I think Lennox owns Armstrong they might be able...

    I think Lennox owns Armstrong they might be able to help.
  34. Replies
    11
    Views
    1,836

    I think so; I've had mine for a while and I have...

    I think so; I've had mine for a while and I have had no problems with it. knock on wood
  35. Replies
    9
    Views
    2,164

    I'm going to think out loud on this one, kink in...

    I'm going to think out loud on this one, kink in a line, TXV power head, compressor breaking up inside lodging debrie in metering device, liquid line valve, service valves not back seated or broke.
  36. Replies
    7
    Views
    982

    Robo, I take it you've seen this before. Also...

    Robo, I take it you've seen this before. Also that make sense since the 1st and 2nd stage were tied together. Why??? I have no idea (LOW BID) I guess.
    I'm going to check with Trane but do you think...
  37. Replies
    7
    Views
    982

    what do you think happened???

    Went on a call today and saw 2 compressors blown out at electrical pins, 2 contactors welded shut, all wires burnt, oil all over the door from the compressors, but the fuses did not open up.
    Trane ...
  38. Replies
    6
    Views
    1,358

    Are the condensor fans spinning the right way?...

    Are the condensor fans spinning the right way? Also if a fan is not running and is pinwheeling backwards, it will make the head pressure go up. Just food for thought.
  39. Thread: 410A

    by toptwo
    Replies
    9
    Views
    646

    410A

    I was told that no matter how good of a vacuum you have you cannot get moisture out of 410A (poe oil). Is this a true statement?... What ever happened to good old mineral oil.
  40. Replies
    9
    Views
    3,010

    Do you work in HVAC field.

    Do you work in HVAC field.
  41. Thread: trane rtu

    by toptwo
    Replies
    8
    Views
    1,106

    what do you mean nothing on hpc is it closed or...

    what do you mean nothing on hpc is it closed or open.
  42. Replies
    23
    Views
    2,466

    Take the bulb and hold it in your hands, the TXV...

    Take the bulb and hold it in your hands, the TXV should start rockin and rollin. If it doesnt start there.
  43. Replies
    11
    Views
    1,911

    Yes... water flow need to check there first.

    Yes... water flow need to check there first.
  44. Replies
    4
    Views
    1,638

    Thats right there are no "high eff" steamers out...

    Thats right there are no "high eff" steamers out there, the best thing to do is size the boiler for the radiators that you have. Also install a drop header in the main to get that little extra bit of...
  45. Replies
    20
    Views
    1,152

    No I'm not a homeowner. I checked subcooling...

    No I'm not a homeowner. I checked subcooling because I thought it had a txv, before I went inside.

    outdoor temp. 70
    return temp 80
    delta t on evap 19
    Also this residential equipment in an...
  46. Replies
    20
    Views
    1,152

    13 seer cond and 10 or less evap.

    What is the problem with this? Besides my findings today. Superheat 3 and Subcooling 19 and there is no TXV in the system. Head pressure around 175 and suction 70 psig.
  47. Try looking for panel coolers. They are designed...

    Try looking for panel coolers. They are designed to keep electrical panels cool.
  48. Replies
    8
    Views
    3,322

    Wow, thats good stuff

    Wow, thats good stuff
  49. Thread: txv adjustment

    by toptwo
    Replies
    6
    Views
    969

    it will take a few minutes to notice any...

    it will take a few minutes to notice any adjustments on a tev. the sensing bulb has to adjust to suction line temp. can take up to 15 min..
  50. Replies
    3
    Views
    766

    check the delta temp and squirrell cage because...

    check the delta temp and squirrell cage because they have been known to bust up and if thats ok i would say weak limit too.