Search:

Type: Posts; User: pringlel

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Altitude Manager v 3.1.14 with Circon Controllers

    I have been asked to over see a building that has a Web based Altitude manager and a building full of Circon controllers. 4 floors of VAV-332-XMV controllers 5 AHU controllers And misc for the...
  2. Thread: Sman3

    by pringlel
    Replies
    61
    Views
    7,186

    Customer service

    Customer service is outstanding, possibly second to none. I was unable to use it on 123 refrigerant, they paid to ship it back, updated the refrigerant charts Recieved a call from Travis informing me...
  3. Replies
    13
    Views
    1,603

    Very Educational

    Thanks for sharing , very well written and educational.
  4. Replies
    51
    Views
    5,624

    Very impressive Mod, I wonder if it will lead to...

    Very impressive Mod, I wonder if it will lead to a design change, or an option upgrade? Itsiceman I would think the sensor leads would get tangled less?
  5. Replies
    14
    Views
    1,918

    Blu Vac

    I recently purchased the blu vac , and I dont have a lot of face time with it yet, but so far I am very pleased. Checked the accuracy against a friends Merc manometer, results where spot on.
    The...
  6. Replies
    2
    Views
    631

    Blackhawk/Proto

    I used to think Blackhawk/proto was decent stuff. Very light tapping from a hammer did a number on these punches. Anyone else have similar issue with there punches?
  7. Replies
    13
    Views
    2,825

    Take Saturated Suter advice he is on the money

    Take Saturated Suter advice he is on the money
  8. Replies
    42
    Views
    3,967

    Is there a way to determine which generation I...

    Is there a way to determine which generation I have ?
    Mine came in the cardboard box maybe it is the latest gen?
  9. Replies
    42
    Views
    3,967

    Do you have a YJ 41 manifold to compare it to , I...

    Do you have a YJ 41 manifold to compare it to , I took the hoses off and checked each port one and a time by opening the valve and blowing through it .
    It is a radical difference between the two I...
  10. Replies
    42
    Views
    3,967

    All 3 ports have a fine mesh screen, it has to...

    All 3 ports have a fine mesh screen, it has to add to a decent amount of flow restriction. I wonder if the SMAN2 has it , or just the SMAN3 for the protection of the micron gauge?
  11. Replies
    42
    Views
    3,967

    It shocked me the amount of resistance to flow...

    It shocked me the amount of resistance to flow with port wide open and hose taken off. I wouldn't want to pull a vacuum through the manifold. I looked inside each port and noticed mesh screens. I am...
  12. Replies
    7
    Views
    1,119

    No need to be sorry, I would rather hear your...

    No need to be sorry, I would rather hear your experiences and opinions.
  13. Replies
    7
    Views
    1,119

    ???????

    ???????
  14. Replies
    7
    Views
    1,119

    That is depressing, does anyone have a list of...

    That is depressing, does anyone have a list of refrigerants that is advertised but not supported?
  15. Replies
    7
    Views
    1,119

    Fieldpiece SMAN3 Sat refrig reading

    Has anyone used it on R-11 system? low side connected reading -13.7 inhg and vsat OL.
  16. Replies
    21
    Views
    2,878

    HVAC Supply house

    Dont over look your local HVAC supply houses as as huge potential to network.
    The guys behind the counter know all the heavy players in your area.
  17. Replies
    21
    Views
    2,878

    Walk in

    Without a doubt walk in, show up with clean work clothes and well oiled work shoes. A firm hand shake and direct eye contact is a pretty good way to introduce yourself.
  18. Thread: sman3 problem

    by pringlel
    Replies
    49
    Views
    4,368

    I was typing and missed your response sounds good...

    I was typing and missed your response sounds good to me thank you.
    Not sure what i was thinking i close my analog set to get my saturated temp readings, sorry guys i had a deer in the headlight...
  19. Thread: sman3 problem

    by pringlel
    Replies
    49
    Views
    4,368

    Maybe its to prevent false superheat readings,...

    Maybe its to prevent false superheat readings, any amount of opening the low side port that allows flow will change its calculated saturated temp. Preventing me from getting an accurate reading....
  20. Thread: sman3 problem

    by pringlel
    Replies
    49
    Views
    4,368

    OL superheat when opening low side port

    I have just tried mine out and one thing that does surprise me is i cant meter in refrigerant on the low side and monitor suction superheat at the same time.
    The display reads OL. Adding refrigerant...
  21. Thread: sman3 problem

    by pringlel
    Replies
    49
    Views
    4,368

    I ordered mine 4-6-11 and was told by the supply...

    I ordered mine 4-6-11 and was told by the supply house it would be in first part of June. Requested order number and call FieldPiece, who informed me my sman3 has shipped and it may arrive tomorrow....
  22. Thread: sman3 problem

    by pringlel
    Replies
    49
    Views
    4,368

    Anyone else having this problem?

    Anyone else having this problem?
  23. Replies
    10
    Views
    1,288

    +1

    +1
  24. Replies
    29
    Views
    4,297

    [QUOTE=jjrr007;10064932]Thanks for letting me...

    [QUOTE=jjrr007;10064932]Thanks for letting me know. I really need to speed up my evacuation time and do a better job with evacuation.

    I like that it has two male (output) ports. I can use one...
  25. Replies
    20
    Views
    1,927

    I would go through withdraws if mine was taken...

    I would go through withdraws if mine was taken away. Cant say enough good things about it, Very well designed, rugged and accurate.
  26. Replies
    2
    Views
    945

    If your at 100 firing rate and your 02 is 0 then...

    If your at 100 firing rate and your 02 is 0 then your problem isnt to much fuel. are you checking gas pressure at inlet to gas regulator or manifold pressure. Manifold pressure usually is allot...
  27. Replies
    14
    Views
    1,809

    If the tax rebate thing is still going on, I am...

    If the tax rebate thing is still going on, I am not sure you can get a heat pump or A/c unit with a high enough seer rating in an unit with a Non Ecm motor. Heat pump i believe is 15 and a/c !6. ...
  28. Replies
    29
    Views
    4,297

    I have 2 and use them often, Quality of build and...

    I have 2 and use them often, Quality of build and function is second to none.
    I let my coworker try them and he as well had to have 2 which are hard to get around here we have to special order them...
  29. Replies
    17
    Views
    1,636

    This is what i use , and have had it for a few...

    This is what i use , and have had it for a few years with no problems
  30. Replies
    9
    Views
    1,199

    You may want to shoot the heads with an Ir gun I...

    You may want to shoot the heads with an Ir gun I usually mark the spot with a black sharpie. As mentioned previously pulling the heads and doing a top end inspection may confirm your abnormal head...
  31. Replies
    7
    Views
    864

    I have the testo 605-h2 which i like alot, not...

    I have the testo 605-h2 which i like alot, not sure what you mean by limited.
    It does wet bulb, dry bulb and RH, plus it comes with a rubber stopper for mounting in ductwork. Huge plus is its small ...
  32. Replies
    2
    Views
    748

    Fieldpiece ST4

    Anyone using the fieldpiece ST4, If so I was wondering what your opinion is?
    Thank you for your time.
  33. Replies
    8
    Views
    1,721

    If you negative fan pressure exceeds your trap...

    If you negative fan pressure exceeds your trap height this can cause the pan not fill and draining properly. Dirty coils if on the suction side of the fan can lower the negative pressure exceeding...
  34. Replies
    17
    Views
    13,120

    I am not sure of a formula, but if memory serves...

    I am not sure of a formula, but if memory serves me if velocities reach or exceed 550 to 600 fpm it will cause condensate to be carried off of the coil.
  35. Replies
    32
    Views
    4,136

    Your apprenticeship class should be starting this...

    Your apprenticeship class should be starting this September, Any confirmation on when school starts? I personally would go visit the girls in the office who supports the training director, and...
  36. Replies
    41
    Views
    4,233

    I would use the company Testo, Does your company...

    I would use the company Testo, Does your company charge an additional fee for a combustion analysis ? Big blue was 125.00 years ago, which was inline with other companies at the time. If they are...
  37. Replies
    41
    Views
    4,233

    Testo 330 just plains owns, it really is rock...

    Testo 330 just plains owns, it really is rock solid. I have had the fireeye Firetron
    Bacharach Commercial model and a UEI model
    Hands down my absolute favorite for reliability and performance....
  38. Replies
    8
    Views
    1,213

    Small Wet/dry vac

    Looking for a small wet /dry vac to carry on the truck. Was wondering what everyone is using ,thank you for your time
  39. Replies
    17
    Views
    2,403

    Prescription safety glasses

    Can anyone recommend a quality brand of prescription safety glasses?
    We have a young first year apprentice , and am hoping we can get him a nice durable pair of safety glasses. Thank you for your...
  40. Replies
    10
    Views
    3,486

    I am sure they are a quality pump , I personally...

    I am sure they are a quality pump , I personally have never had one. So my opinion is extremely shallow and is based off of looks and perception.
    Now i would take the Welsh Duo-seal :) Truth be...
  41. Replies
    10
    Views
    3,486

    Isnt dealing with the little oil sight glass...

    Isnt dealing with the little oil sight glass painful?
    For the sight glass alone you couldnt give me that pump
  42. Replies
    10
    Views
    1,368

    Definitely should be more efficient because your...

    Definitely should be more efficient because your reusing the heat from the condenser.
  43. Replies
    6
    Views
    1,171

    I believe its sized for the min load so if its a...

    I believe its sized for the min load so if its a 2 stage 20 ton and there 2 10 tons then it should be sized for 10 ton , with min condensing temps as a factor
    sporlan Bulletin 90-40 will explain it...
  44. Replies
    10
    Views
    1,368

    If you are going to attempt to dehumidify with no...

    If you are going to attempt to dehumidify with no reheat. Very good capacity control is key Hot gas bypass would help you reduce your capacity and still stay on line. If you dont have the load to...
  45. Replies
    141
    Views
    18,366

    I grew up about 80 miles southwest of Buffalo,...

    I grew up about 80 miles southwest of Buffalo, Randolph and Salamanca NY
  46. Thread: Job Dilemma

    by pringlel
    Replies
    8
    Views
    808

    Tech helper so much more fun, All I have to do is...

    Tech helper so much more fun, All I have to do is look at sheetmetal and i get cut
  47. That is excellent news !:CU:

    That is excellent news !:CU:
  48. Replies
    141
    Views
    18,366

    How is the work situation, did you get placed ?

    How is the work situation, did you get placed ?
  49. Replies
    3
    Views
    483

    I thought they shut that plant down, What does a...

    I thought they shut that plant down, What does a test operator do?
  50. Replies
    73
    Views
    5,688

    Not sure that i will agree with you, but thats...

    Not sure that i will agree with you, but thats the nice part of this forum we can agree that we disagree :LOL:
    They have companies in this area that specialize in combustion year round
    I have made...
Results 1 to 50 of 333
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event