Search:

Type: Posts; User: teamkudzu

Search: Search took 0.00 seconds.

  1. Replies
    10
    Views
    1,820

    noskilltech, do you have the CAF file for this?...

    noskilltech, do you have the CAF file for this? If so could I get a copy? I am looking at doing the same on a couple of units.

    Thanks,
  2. Replies
    27
    Views
    4,206

    I saw this on youtube and was wondering what is...

    I saw this on youtube and was wondering what is up with this Yellow Jacket digital manifold as it is duplicate of the Digicool it seems.I know they have a new version out but was wondering about this...
  3. Replies
    70
    Views
    10,362

    Comments below... [QUOTE=klove;9631642]That...

    Comments below...

    That Blue Koolaid is pretty darn good when I will be retired and sitting on a lake fishing.
  4. Replies
    70
    Views
    10,362

    Pretty much sums it up,and if York was doing so...

    Pretty much sums it up,and if York was doing so great why was it up for sale?Why didn't York buy JCI and set JCI straight on how to run a business?:whistle:

    Some of you guys who post on here are a...
  5. Replies
    7
    Views
    1,902

    Can't get the forum to upload the format. Here...

    Can't get the forum to upload the format.

    Here is the attribute info you asked for on a PID loop:
    Z (n*) Working Setpoint (WSP)

    A (1) Process Variable (PV)
    A (2) Output...
  6. Replies
    7
    Views
    1,902

    X=Analog inputs Y=Outputs D=Digital inputs XT...

    X=Analog inputs
    Y=Outputs
    D=Digital inputs
    XT will get you into the Extension modules
    Z=Pid modules
    A=Attributes
    If I can find an old "cheat sheet" I will post it up
  7. Replies
    2
    Views
    544

    You just have to update to major revisions one at...

    You just have to update to major revisions one at a time to be safe is all(2 to 3 to 4 to 5)No need to send off to India...

    If they don't have a copy of Rev 2 loaded they are not wanting to the...
  8. Replies
    100
    Views
    13,737

    Well at least you anchored them down so they...

    Well at least you anchored them down so they don't get blowed away by the wind...
  9. Replies
    8
    Views
    2,107

    NCE

    NCE will do it through the WEB but for that cost you can replace the device itself.
    ...
  10. Replies
    4
    Views
    1,412

    I haven't done much residential work in...

    I haven't done much residential work in years,wish I would have had a camera back them to document some of the things I saw.

    Now as far as some of the things you guys have posted pics of on(like...
  11. Thread: Micron what?

    by teamkudzu
    Replies
    26
    Views
    4,444

    Go back and ask him how he knows if the seals are...

    Go back and ask him how he knows if the seals are still good in his vacuum pump,then look at him when he gives you that weird look and say "they do go bad,you know"
  12. Thread: Lennox help

    by teamkudzu
    Replies
    6
    Views
    3,419

    Thanks guys:)

    Thanks guys:)
  13. Thread: Lennox help

    by teamkudzu
    Replies
    6
    Views
    3,419

    ascj, One more question if you can help, 3...

    ascj,

    One more question if you can help, 3 phase or single phase?

    Saleman brought only a model # back from the job site.
  14. Thread: Lennox help

    by teamkudzu
    Replies
    6
    Views
    3,419

    Thank you!

    Thank you!
  15. Thread: Lennox help

    by teamkudzu
    Replies
    6
    Views
    3,419

    Lennox help

    Looking for specs on a GCS16-953-200-6Y

    Tonnage and btu input.
  16. Thread: NCM help

    by teamkudzu
    Replies
    7
    Views
    604

    You need a network with actual field devices.

    You need a network with actual field devices.
  17. Replies
    10
    Views
    1,545

    You are to funny,seriously. The reason the freeze...

    You are to funny,seriously. The reason the freeze on PC's is because they will be replaced with a new HP laptops that work inplace of the NEXGYN handhelds device and support MSEA for techs.Why would...
  18. Replies
    7
    Views
    755

    Pull the power until all lights are extinguished....

    Pull the power until all lights are extinguished. Re power and wait until Run light is on steady and no activity on the PEER light.
  19. Replies
    10
    Views
    1,545

    Wow Freddy-B getting a little slow with your info...

    Wow Freddy-B getting a little slow with your info uhnn? Been on the horizon for almost a year for the field guys and has been put into place in several branches already.Might need to buy a few more...
  20. Replies
    46
    Views
    4,613

    Is it physically mounted to the unit? Did you not...

    Is it physically mounted to the unit? Did you not "tear into it" just to see what it was, I know I would have.Guess I am just nosey...

    Anyway it doesn't look to be over the condenser anyway.Looks...
  21. Replies
    44
    Views
    6,759

    That is pretty much any JCI thread and...

    That is pretty much any JCI thread and Freedy_B...:D
  22. $2399.99 here. :D

    $2399.99 here.
    :D
  23. Replies
    59
    Views
    5,055

    Freddy B,Please link me to where you are selling...

    Freddy B,Please link me to where you are selling all of these terrible devices you hate so much.I know several who will be willing to buy these "pieces of junk" that you are constantly ripping...
  24. Yes,only option not released yet I believe is the...

    Yes,only option not released yet I believe is the heatpump contoller. See page 8
    ...
  25. Even though some on here only visit here to flame...

    Even though some on here only visit here to flame JCI,here is something else from JCI instead of the Tec zone control that no one has yet mentioned and it takes all of 30 minutes to setup once...
  26. You will have to send it in to JCI and have the...

    You will have to send it in to JCI and have the password reset to download or make any changes if you do not have a working password.
  27. Replies
    3
    Views
    429

    Resetting an alarm or the N30 itself? If the N30...

    Resetting an alarm or the N30 itself? If the N30 why do you think you need to reset it,is it locked up/no live data?

    To clear alarms is the F1 button after logging in.
    To reset N30,cycle power.
  28. Thread: Pneumatic

    by teamkudzu
    Replies
    21
    Views
    1,511

    Install a pilot positioner on one valve to set...

    Install a pilot positioner on one valve to set the stroke offset if both work at the spring range currently.If they are both "odd" spring ranges but a positioner on both.
  29. Thread: FEC's

    by teamkudzu
    Replies
    48
    Views
    2,553

    4.1 is already out, The Java problem came about...

    4.1 is already out,
    The Java problem came about at 4.0 with the difference in SCT and CCT and stepping back to prior releases.The ANY_JAVA patch was to fix that.
  30. Thread: FEC's

    by teamkudzu
    Replies
    48
    Views
    2,553

    You need the correct JAVA for the version of CCT...

    You need the correct JAVA for the version of CCT you are running.Might not be the same as the NAE is needing to run.
  31. Slave a relay off of the signal to the gas valve...

    Slave a relay off of the signal to the gas valve and either power or monitor the contacts.:confused:
  32. Replies
    6
    Views
    593

    Download the one you got off of the network and...

    Download the one you got off of the network and see if it performs the same...............:DJUST KIDDING!


    Open up the DX20.dxs that you got off the network and compare it point by point to the...
  33. Replies
    16
    Views
    11,508

    If you can show an invoice where you actually...

    If you can show an invoice where you actually paid for your original copy of software you can get another one at small cost.
  34. Thread: BacNet TEC's

    by teamkudzu
    Replies
    9
    Views
    986

    Berg, is it just the TEC's or are other devices...

    Berg, is it just the TEC's or are other devices also bouncing?
  35. Replies
    15
    Views
    2,247

    Sort of along the same lines with Trane and their...

    Sort of along the same lines with Trane and their Eagle software... :rolleyes:
  36. Replies
    18
    Views
    1,259

    The older York heat pumps did have a balance...

    The older York heat pumps did have a balance point to lock out the heat pump below balance point,which there was documentation depending on the part of the country as to where to set it(been a long...
  37. Replies
    62
    Views
    5,405

    What is the difference with working in a right to...

    What is the difference with working in a right to work state for a company who has some unionized techs yet you are not union?
Results 1 to 37 of 43
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event