  1. Replies
    19
    Views
    3,668

    Does that valve have a screen you can check? If...

    Does that valve have a screen you can check? If not then I would go with the power head or just the valve all together.
  2. Replies
    18
    Views
    1,333

    Ok to start let me say that I mean no disrespect...

    Ok to start let me say that I mean no disrespect to you guys and agree with alot of what you are saying but just becawse this unit was 19 or even 20 yrs old does not mean it was junk. There alot of...
  3. Replies
    11
    Views
    1,892

    OK so this machine makes three batches of ice the...

    OK so this machine makes three batches of ice the locks out. when this curtain switch makes it should go right back to the freeze cycle. Are you sure the machine is level? you should see lights from...
  4. Replies
    12
    Views
    3,585

    I think either non condensibles or very dirty...

    I think either non condensibles or very dirty condensor coils. Your head is out of the ball park on this one.
  5. Replies
    21
    Views
    1,783

    I would say you could have a restricted dryer but...

    I would say you could have a restricted dryer but also sounds like the t stat needs replacing as well. I know first hand these can be a pain but I would be willing to bet that your dryer is...
  6. Replies
    22
    Views
    3,749

    I remember a copeland class about valve plates...

    I remember a copeland class about valve plates that they mentioned 2 to 5 seconds of liquid in the suction line can do terminal damage to the compressor. I also have seen this copper partical you...
  7. Unless you are having issues farther down the...

    Unless you are having issues farther down the trunk line like lack of air flow it shouldnt make a major difference.
  8. Replies
    41
    Views
    3,541

    My suggestion as from my own exp. is to have an...

    My suggestion as from my own exp. is to have an air balance as well as pressure. Here in ohio in most new construction we install a 4 to 6 inch round duct streight to the outside and to the return...
  9. Replies
    6
    Views
    3,462

    My personal opinion would be either to go with...

    My personal opinion would be either to go with the up flow furnace or relocate to the attic either way your furnace is over 20 years old and if you dont please have it inspected very well for cracks...
  10. Replies
    7
    Views
    929

    If your talking about the wall panels I would...

    If your talking about the wall panels I would suggest a good utility knife and go along the edges just dont cut the seals. This plastic peals right off. Hope this helps but its gonna be cold....
  11. Replies
    15
    Views
    1,374

    I spent alot of money for school and found out...

    I spent alot of money for school and found out after 3 yrs that I only scratched the surface and those big checks they tell you about well dont expect those for quite some time and alot of sweat. My...
  12. Replies
    6
    Views
    2,336

    My main exp. in the field is refrigeration and we...

    My main exp. in the field is refrigeration and we always trap any suction line with a rise of 8 ft or more. Also as stated by the others I would use a secondary trap and an inverted trap above to...
  13. Thread: New to site

    by mcljkl
    Replies
    5
    Views
    557

    Welcome. I would say if you look really hard you...

    Welcome. I would say if you look really hard you can find a good company to get in the door with but exp. pays so dont expect the big bucks they promise you in school. Its a hole different world once...
  14. Thread: Introduction

    by mcljkl
    Replies
    2
    Views
    480

    welcome I am sure your going to like it. I have...

    welcome I am sure your going to like it. I have found so much useful info and look forward to talking to you. Again welcome
  15. Thread: New Here

    by mcljkl
    Replies
    72
    Views
    7,506

    Welocme and I will say that there just arent...

    Welocme and I will say that there just arent enogh women in the field and I respect you for your hard work. Hope we can share some trade info some time.
  16. Thread: TRANE ES SYSTEM

    by mcljkl
    Replies
    0
    Views
    667

    TRANE ES SYSTEM

    So can anybody give me an area online to find information on TRANE ES monitoring systems. I just had training on this its a new account and the trainer said it was impossible to get info on this...
  17. Replies
    7
    Views
    546

    sorry for not replying sooner

    Sorry guys for the late reply.... Yes it means Energy Management Systems. I had some medical issues a while back and now I am a desk jockey but still get to talk to and help techs figure problems out...
  18. Replies
    3
    Views
    430

    Just sayin hello

    Guys just thought I would say hello. 15 yr tech now in energy managment :couchhide:
  19. Replies
    7
    Views
    546

    Just introducing myself

    Hello to all I have been in the field for 15yrs and now monitor EMS for locations around the USA.