Search:
Type: Posts; User: IceVicious
Search: Search took 0.01 seconds.
-
02-05-2013, 04:10 PM
- Replies
- 3
- Views
- 1,739
they are built like a battleship , I love Vogts...
they are built like a battleship , I love Vogts by far my fav, unit to work on , what are you adjusting ice thickness ??
-
02-05-2013, 04:03 PM
Thread: Hot Side Equipment Tool List
by IceVicious- Replies
- 7
- Views
- 915
Thanks ECtoFIX , only thing i have thats i little...
Thanks ECtoFIX , only thing i have thats i little diff is in stead of floor jack i use a "auto body frame straightener" , lift griddles , entire units ,
little more versatile.
Thanks again -
02-05-2013, 03:59 PM
Thread: Soft Serve Machine Comparison
by IceVicious- Replies
- 8
- Views
- 2,114
Check your T-stat , if thats ok , call EF tech....
Check your T-stat , if thats ok , call EF tech. what ever you do UNPLUG THE UNIT BEFORE TOUCHING IT.
GOOD LUCK
Peace out.
Ice V -
02-05-2013, 03:55 PM
Thread: Round up Steamer issues
by IceVicious- Replies
- 6
- Views
- 489
thanks for correcting me Sir
thanks for correcting me Sir
-
02-05-2013, 03:53 PM
Thread: need some help
by IceVicious- Replies
- 3
- Views
- 449
I would try installing a computer exhaust fan (it...
I would try installing a computer exhaust fan (it wont last in grease) or wrapping motors or fryer well in heat shield insulation.
-
02-05-2013, 03:48 PM
Thread: Electro Freeze factory service advice.
by IceVicious- Replies
- 24
- Views
- 3,661
What happened to this guy , he just leave us...
What happened to this guy , he just leave us hangin ??? kinda scary
Ice V -
02-04-2013, 09:43 PM
Thread: super heat
by IceVicious- Replies
- 8
- Views
- 458
my signature says it all lol.
my signature says it all lol.
-
02-04-2013, 10:24 AM
Thread: Round up Steamer issues
by IceVicious- Replies
- 6
- Views
- 489
Check to see your water pressure is no more than...
Check to see your water pressure is no more than 25 psi , if so they sell reg/filter kits that go with steamers
-
01-28-2013, 12:23 PM
Thread: Electro Freeze factory service advice.
by IceVicious- Replies
- 24
- Views
- 3,661
hi im working on a cmt 30 , the cabinet temp is...
hi im working on a cmt 30 , the cabinet temp is about 25 degrees even when the switch is off ,
compressor kicks on every 5 min for about 30 sec , no matter what
any ideas -
01-25-2013, 01:55 PM
- Replies
- 13
- Views
- 976
you gotta wonder with all the China crap coming...
you gotta wonder with all the China crap coming out
-
01-25-2013, 01:46 PM
Thread: Discharge pressure on ice machine?
by IceVicious- Replies
- 30
- Views
- 1,407
water cooled or air cooled , Man i remember a...
water cooled or air cooled , Man i remember a couple years ago Scotsman had issues with the dist. tubes coming off TXV , causing uneven ice forms and high head , if its a remote ,
check your gas ... -
01-25-2013, 01:39 PM
Thread: Rack Systems in Low Ambient Conditions
by IceVicious- Replies
- 65
- Views
- 2,122
I think the best way is splitting the cond. some ...
I think the best way is splitting the cond. some Walmart's use this along with fan cycling , im not a big fan of head masters .
Ice V -
01-25-2013, 01:34 PM
Thread: Next refrigerant to replace 404a
by IceVicious- Replies
- 30
- Views
- 2,275
Yes it was a new compressor and yes i drained...
Yes it was a new compressor and yes i drained min. and replaced with POE ,
I WAS TOLD SOON ALL COMPRESSORS FROM COPELAND WILL HAVE POE , could BS not sure
IceV -
01-24-2013, 10:11 AM
Thread: Next refrigerant to replace 404a
by IceVicious- Replies
- 30
- Views
- 2,275
R407C
, POE only gas (R407C) , I just retrofitted a Walk in cooler with it , So far so good
seems somewhat stable. we shall see. -
01-23-2013, 03:03 PM
Thread: Next refrigerant to replace 404a
by IceVicious- Replies
- 30
- Views
- 2,275
Profits must be down at the almighty...
Profits must be down at the almighty Dupont:deadhorse::deadhorse:
-
01-23-2013, 01:59 PM
Thread: electro Freeze soft serve
by IceVicious- Replies
- 22
- Views
- 4,147
Other than checking your mix and for air leaks...
Other than checking your mix and for air leaks you need to get a hold of a Refrigeration Tech. Im sorry unless your in Colorado i cant really help any further
IceV -
01-23-2013, 11:16 AM
Thread: electro Freeze soft serve
by IceVicious- Replies
- 22
- Views
- 4,147
Electro Freeze
Well if its a CMT 30 with dual Compressors , Remember that Left side cools the Cabinet also , Check your Refrigerant level , check the Mxv , Sol. valve , , etc. etc. if its more than 10 years old ,...
-
08-10-2010, 07:04 PM
Thread: cap tube replacement
by IceVicious- Replies
- 22
- Views
- 1,717
ka-ching
What a great selling point to push P/M CONTRACTS , Clean condensers is what i mean !
KA-CHING!
Ice V -
08-09-2010, 06:51 AM
Thread: Hoshizaki KM
by IceVicious- Replies
- 7
- Views
- 495
Well you either have a Thermistor issue or a head...
Well you either have a Thermistor issue or a head pressure issue , the unit is not generating enough heat for the thermistor to terminate, defrost or its bad. Its the once a month thing that has me...
-
08-08-2010, 02:16 AM
Thread: Deli Case - not behaving
by IceVicious- Replies
- 16
- Views
- 808
BALLEST ????
BALLEST ????
-
08-08-2010, 02:13 AM
Thread: scroll internal check valve
by IceVicious- Replies
- 8
- Views
- 1,241
" you want how much for that compressor" (cough cough)
Craig you speak the truth , fortunately the margin on new cond units is the same lol. cause selling hot water in hell aint easy lol
-
08-08-2010, 02:05 AM
Thread: Scotsman CME 806 Controller Error?
by IceVicious- Replies
- 2
- Views
- 897
Blue or black
Make sure all your plugs are in correct spot , if its a Blue universal , make sure the setting on the side is for a 806,If its Black replace it 4-sure regardless i would replace the controller. Good...
-
08-08-2010, 01:58 AM
- Replies
- 21
- Views
- 1,114
With the new Grasslin clocks the box is vapor...
With the new Grasslin clocks the box is vapor tight so for mid temp its ok to mount inside, low temp im with poodle, not only does freezing suck , but 10 below plays havoc with every mechanical...
-
08-08-2010, 12:02 AM
Thread: freezer floor
by IceVicious- Replies
- 10
- Views
- 976
Stuff works awesome for PISTOL GRIPS ALSO HE HE.
Stuff works awesome for PISTOL GRIPS ALSO HE HE.
-
08-07-2010, 11:33 PM
Thread: True Doors
by IceVicious- Replies
- 7
- Views
- 525
People tend to overload the living s**t out of...
People tend to overload the living s**t out of them , causing the problem " Icemeister" refering too. also Cooks find those doors a nice object to take frustrations out on lol good luck.
IceV
Results 1 to 25 of 109