  1. Replies
    11
    Views
    516

    med temp rack off cycle defrost. when talking...

    med temp rack off cycle defrost. when talking about bypass I use a superhose from discharge to outlet side of the valve
  2. Replies
    11
    Views
    516

    gas logging in reciever

    having a problem with Hill phoenix rack, when it 90 degress and above the gas logs in the receiver. the liquid line psi is higher than the receiver psi. being that this is a receiver with one way in...
  3. Replies
    11
    Views
    537

    yes hot water reclaim 5 ft away

    yes hot water reclaim 5 ft away
  4. Replies
    11
    Views
    537

    Not asking what to do, have done already, Was...

    Not asking what to do, have done already, Was asking why opening the hold back valve with such low head allow me to get discharge back. I did forget to mention added more gas, but started to get...
  5. Replies
    11
    Views
    537

    rack head psi at 59 lbs

    arrived on site all fixtures warm no liquid in receiver one of 5 compressors running because if another one came on it would almost immeadiately reach suction target, anyway after fumbleling around...
  6. Replies
    1
    Views
    246

    direct connect to e2

    Hi everyone, Can anyone tell me how to step by step how to set my laptop up to direct connect to e2 ? on my old laptop it was set up for me y this controls guy and I used it once and never did it...
  7. Replies
    2
    Views
    386

    yes ,but that's what they want

    yes ,but that's what they want
  8. Replies
    2
    Views
    386

    b acurach hgm 400

    hi guys,
    they just install this in a bj's . Bj's set points are 5 ppm for a leak alarm with a 1 second delay. having a very hard time pinpointing this leak in the zone it is said to 'be in. I will...
  9. Replies
    6
    Views
    436

    so this is done without a router? and how do you...

    so this is done without a router? and how do you use team viewer only to control the computer that monitors the refrigeration.
  10. Replies
    6
    Views
    436

    I am not an energy management guy but enjoy...

    I am not an energy management guy but enjoy knowing all aspects of the game , basically I want to learn how this is done . oh I do have teamviewer install on my computer, so can you explain how I...
  11. Replies
    6
    Views
    436

    energy management

    I have not came across anyone doing this yet ,but would like to know how its done. A tech told me that he saw a guy doing start up work and he had his lab top hook up to the controller in the machine...
  12. Replies
    6
    Views
    382

    how do u determine if a condensor for the rack or...

    how do u determine if a condensor for the rack or reclaim is the proper size
  13. Replies
    6
    Views
    382

    heat reclaim fills up reciever

    hi all I was talking with a tech, and a very exspirenced one at that says he could not figure out this issue he had that in the summertime when the heat rec shut down the receiver fills up. don't...
  14. Replies
    4
    Views
    345

    not sure, looking for some lit to explain how...

    not sure, looking for some lit to explain how they suppose to work can u explain or guide me to where I could find some lit
  15. Replies
    4
    Views
    345

    yes but why would they pump out the condensor...

    yes but why would they pump out the condensor whenever the fans cycle off,not just when its in split
  16. Replies
    4
    Views
    345

    microchannel condencesor

    hi all , Just got a store that has these condensers on a zero zone rack. the racks are a,b,c all combined with 3 micro channel condersers,I was told that sections of the coils has valves that...
  17. Replies
    0
    Views
    161

    p445 oil control to sentronic 3

    just in case i had to change out the johnson oil control p445 to sentronic 3 will i put the 240 to240 on sentronics then use m1 and m2 as l and m and use the noa as the alarm circuit and cap the cma...
  18. Thread: comtrol 6k

    by jaybee
    Replies
    5
    Views
    378

    Do u have a contact number ???? Check your...

    Do u have a contact number ???? Check your private messages
  19. Thread: comtrol 6k

    by jaybee
    Replies
    5
    Views
    378

    do u have a contact number. Check your private...

    do u have a contact number. Check your private messages
  20. Thread: comtrol 6k

    by jaybee
    Replies
    5
    Views
    378

    . Yeah I know fred . He is just very busy with...

    . Yeah I know fred . He is just very busy with other projects , just don't like to bother him to much.
  21. Thread: comtrol 6k

    by jaybee
    Replies
    5
    Views
    378

    comtrol 6k

    where are u guys getting support now to work on 6ks. ie screen calibrations and dos commands needed to to work on theses units.Danfoss knowelge is very limited.Do anyone know anybody. Any replies are...
  22. Replies
    30
    Views
    3,160

    THANKS

    THANKS
  23. Replies
    11
    Views
    1,836

    So i guess if u have a pressure activated...

    So i guess if u have a pressure activated unloader there is no real way of knowing unless you remove the heads huh. Sorry
  24. Replies
    11
    Views
    1,836

    32 PLEASE NOTE THE LAST PARAGRAPH 2.4 — Service...

    32 PLEASE NOTE THE LAST PARAGRAPH
    2.4 — Service Procedures
    The service section covers replacement of valve plates
    and gaskets, service to the bearing head assembly
    containing the oil pump, and a...
  25. Replies
    11
    Views
    1,836

    CARLYLE O6E or any compressor with a pressure...

    CARLYLE O6E or any compressor with a pressure activated unloader