  1. Replies
    13
    Views
    1,307

    They have to communicate with eachother. They...

    They have to communicate with eachother. They work together. Just did this. Couldn't finish the job on a Friday and tried to run it with one.
  2. Replies
    11
    Views
    778

    Aren't you slugging the compressors being that...

    Aren't you slugging the compressors being that far away? I turned a job down like that because the manufacturer said it was too far. They said the line set couldn't change temperature more than 3...
  3. Replies
    13
    Views
    780

    Draft. Or internally blocked by something you...

    Draft. Or internally blocked by something you can't see.
  4. Replies
    13
    Views
    780

    That sounds like too much air. What's you'r co2...

    That sounds like too much air. What's you'r co2 on it? I've run into this before and had transformers that would run fine for a bit but once they heat up they won't go. It sounds like your working...
  5. Replies
    13
    Views
    780

    Does it go off on safety? Maybe the ignitor is...

    Does it go off on safety? Maybe the ignitor is heating up and going off on safety? Is this an nx burner?
  6. Replies
    13
    Views
    780

    Fan*

    Fan*
  7. Replies
    13
    Views
    780

    Also is there an exhaust can or anything like...

    Also is there an exhaust can or anything like that running in the house?
  8. Replies
    13
    Views
    780

    Make up air in the room. Your adding air to light...

    Make up air in the room. Your adding air to light it when you open that door. Pump pressure too like someone mentioned.
  9. Thread: Concept 1200

    by BPToilman
    Replies
    2
    Views
    224

    Checked em, sprayed everything with the soap

    Checked em, sprayed everything with the soap
  10. Thread: Concept 1200

    by BPToilman
    Replies
    2
    Views
    224

    Concept 1200

    Had a no go on an concept 1200 the other day. No charge, 4 ton unit. I put the nitrogen in, 500psi no leaks. Held for an hour. Charge it, tell him to keep an eye on it. 2 days after he started...
  11. Replies
    29
    Views
    2,804

    It's oem. Ducane cu. just checked inside coil and...

    It's oem. Ducane cu. just checked inside coil and outside coil. Both clean as a whistle. I put the txv in a cup of ice water and saw a 5 psi change on the suction line. Put the door back on and it's...
  12. Replies
    29
    Views
    2,804

    75 in the house. Got the superheat from the pt...

    75 in the house. Got the superheat from the pt chart, 60 degree suction temp, 125-130 suction pressure. I know the coil is clean because it's a new unit (2 months or so) I guess I can't rule that out...
  13. Replies
    29
    Views
    2,804

    I didn't check sub cooling because I figured it...

    I didn't check sub cooling because I figured it would be way off due to the pressure on the high side. I'll try this stuff tomorrow. What about it being stuck though? My gauges wouldn't move off of...
  14. Replies
    29
    Views
    2,804

    Yes superheated was 17. I think I've read on here...

    Yes superheated was 17. I think I've read on here before that you can take the bulb off and wrap it in a hot towel to see if it clicks and opens.
  15. Replies
    29
    Views
    2,804

    I would think that with the pressure that high it...

    I would think that with the pressure that high it would be closed, or stuck half way open? I know the coil is clean. It is 410
  16. Replies
    29
    Views
    2,804

    Looks like the txv is sticking. I had a high side...

    Looks like the txv is sticking. I had a high side pressure of 390 and a suction line pressure of 125. 80 degrees out here today. I couldnt see the pressures fluctuate at all.
  17. Replies
    29
    Views
    2,804

    Not a do it yourself buddy. It was 9:30 at night....

    Not a do it yourself buddy. It was 9:30 at night. No pressure readings. Didn't know if it was possible for pressures to spike on the start like that after it had run fun and there wasn't a heavy load...
  18. Replies
    29
    Views
    2,804

    I reset the switch. I looked at it this...

    I reset the switch. I looked at it this afternoon. Funny thing is, it hasn't been hot here. Not humid and I know the unit hasn't run.
  19. Replies
    29
    Views
    2,804

    High pressure switch

    What could cause a high pressure switch to trip when the unit hasn't run in 6 days. Unit was running fine for the whole summer. Homeowner says he shut it off 6 days ago. Turns it on today and the...
  20. Hydro air?

    Hydro air?
  21. Replies
    24
    Views
    1,963

    Like someone said the hx is prob acting as...

    Like someone said the hx is prob acting as another coil. The hx is prob slowing the air down enough that it will start to condense on the warmer metal. How hot is it in the basement?
  22. Replies
    6
    Views
    995

    Just ran into this today. Unit Was buzzing When i...

    Just ran into this today. Unit Was buzzing When i got there. Compressor or motor? Fan spun easily. I threw a hard start on to see if I could get the motor to start. Wouldn't go but pulled the...
  23. Replies
    9
    Views
    867

    Not hot enough here today to get any readings....

    Not hot enough here today to get any readings. Only 62!!
  24. Replies
    9
    Views
    867

    Will get them in the morning. Thanks guys

    Will get them in the morning. Thanks guys
  25. Replies
    9
    Views
    867

    1100cfms is what the furnace (ducane) is register...

    1100cfms is what the furnace (ducane) is register on the board. Don't know if that's actual cfms or not.