Search:

Type: Posts; User: acdude32

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    13
    Views
    961

    yes test under a load, it is the best way to...

    yes test under a load, it is the best way to determine what that run cap is doing. Even if it is good at least you will know exactly what that cap is doing when it is doing what it does :)...
  2. wait 1/4" per foot.... what??? ok wait lets do...

    wait 1/4" per foot.... what??? ok wait lets do the math 4ft is a 1" drop wow, so 10ft is a 2.5" drop and 20 feet is a 5" drop roughly??? would that be like a 1/12 pitch on a roof? I was always...
  3. OK well ummmm wow where do I start....... whew ...

    OK well ummmm wow where do I start....... whew no to much effort and just too easy. what state do you live in I need to go there I will stay busy year around. and if you did that and are nate...
  4. Replies
    63
    Views
    2,552

    Wow ok well I got slammed pretty hard at first ...

    Wow ok well I got slammed pretty hard at first but I do see what you all are saying. Now I will say I am a man of proof I go by facts based on what manufacturers report. If they say I need to...
  5. Replies
    63
    Views
    2,552

    22/410a multipoupose gaues lol

    So my co worker today was showing me his only set of gauges, he uses them for 22 and 410a, so I said do you do anything after you use them one 22 and go to 410 he said no why its just refrigerant....
  6. Replies
    10
    Views
    622

    testing run caps HOT

    So several years ago I was taught how to test run caps hot, I thought it was the coolest thing ever. so as many years went on and I started asking people if they knew how more and more have said no...
  7. Replies
    14
    Views
    957

    Wow thank you all for your replies they are well...

    Wow thank you all for your replies they are well received and it seems like maybe the better choice here would be to go with the FP I will try them for a year and see how I like them, and maybe by...
  8. Replies
    34
    Views
    2,074

    wow well thank all of you for your input. I...

    wow well thank all of you for your input. I printed this post he got mad that I put it out there for everyone to see, I said hey I never said where you worked or what your name was, but I sat him...
  9. Replies
    14
    Views
    957

    which to buy testo or fieldpiece hmmmm

    Ok before all of you slam me this is what I am asking, I want to get the testo 570 , now that having been said I also like the warrenty of the FP and the fact that I don't have to send it off to...
  10. Replies
    34
    Views
    2,074

    oh you know I will. I want to see his reaction,...

    oh you know I will. I want to see his reaction, I don't know everything in this industry although I have done it for 30 yrs, I would put my RESIDENTIAL knowledge against anyone, and if I am wrong...
  11. Replies
    34
    Views
    2,074

    how do you charge a txv system . hmmmm

    OK so at work me and another tech got to talking I have been in this field for 30 yrs he for 15 yrs ok well so here we go. he stated that he checks his txv system charge via super heat, I said...
  12. Replies
    4
    Views
    408

    Are you replacing defrost sensors as well or just...

    Are you replacing defrost sensors as well or just the board ,have you tested the defrost sensor? Have you put a board in then tested the board to insure it is working properly, or are you just...
  13. Thread: flame sensors

    by acdude32
    Replies
    12
    Views
    697

    I think I will look up and see if I can find out...

    I think I will look up and see if I can find out what the old flame rod sensors where made of and what they are made of now may be just that material composition is different
  14. Replies
    50
    Views
    6,565

    Ok look I haven't read all these but I will say ...

    Ok look I haven't read all these but I will say this when I had my shop I payed like this, 1-3yrs $12 pre hr,3-5 yrs $15 per hr, and 5-7 yrs $18 per hr ,7-10 yrs was $20 per hr, now the gap ...
  15. Replies
    1
    Views
    527

    looking for work

    Ok well I have been in Abilene Tx. now for 5 yrs I have 30 yrs of hvac knowledge and experience. I did 6 yrs in the army doing hvac,then got out and worked as an installer for a year, moved to...
  16. Replies
    5
    Views
    551

    yep good call and ty all for the help wow this...

    yep good call and ty all for the help wow this is what I love about this job most you never stop learning, and it is never boreing ty again guys :)
  17. Replies
    5
    Views
    551

    hey monkey tyvm didn't even think about that, I...

    hey monkey tyvm didn't even think about that, I will look for the metering device on Monday that makes a lot of sence why both lines are sweating and why all these units of this brand are running...
  18. Replies
    5
    Views
    551

    haier mini slpit line set size

    ok so at work we have several haier 18k btu mini splits. and I was called on one that is wasn't cooling so I go look and find this low suction pressure and crazy low head pressure. this is a 410a ...
  19. Replies
    2
    Views
    596

    ty

    ty for the info that was perfect tyvm:)
  20. Replies
    2
    Views
    596

    looking for schematic

    i need to see is anyone has or knows where to find a schematic for a commercial payne gaspack it says modle number is 585EP060100 as far as i can tell. any help would be appreciated ty.
  21. Replies
    21
    Views
    6,142

    ok look lets understand and agree on certain...

    ok look lets understand and agree on certain points. first all the work is done in canada so forget about building codes they are different than here annd the laws are different, second it is an hr...
  22. Replies
    26
    Views
    1,322

    no problem i thought i hinted at that through out...

    no problem i thought i hinted at that through out this post but maybe i didnt
  23. Replies
    26
    Views
    1,322

    Thanks born i didnt mean to make it sound as if i...

    Thanks born i didnt mean to make it sound as if i would crawl up in a corner and wait for the grim reaper to get me at 65, of course i will be teaching much as i do now. i was more refering to me,...
  24. Replies
    26
    Views
    1,322

    well to answer the question "why have i gone to 3...

    well to answer the question "why have i gone to 3 trade schools?"
    answer the first one was back in 83 the next was in 86 and the last was in 99 why you ask. well the army was in 83 and after i...
  25. Replies
    26
    Views
    1,322

    OK so far i like the input, i have taken a couple...

    OK so far i like the input, i have taken a couple shots here and that is fine, i love to be critiqued thank you, makes me think.
    Now I am not trying to say i am a super tech, not by any stretch...