  1. Replies
    6
    Views
    369

    Internal server request used to appear back in...

    Internal server request used to appear back in the web ops/web server days. Is there another BACnet workstation on the network that is writing to it? You can telnet to the BCU and scan for all...
  2. Replies
    5
    Views
    454

    I would add 100 gpm like stated and see how well...

    I would add 100 gpm like stated and see how well the system handles it. I'm also a fan of evap DP over flow meters. I've never found a flow meter that wasn't a piece of garbage.
  3. Replies
    14
    Views
    992

    Thanks for the input and ideas. I was talking to...

    Thanks for the input and ideas. I was talking to our rep that we'll be buying the JACE through and he mentioned the Spyder ILC or whatever the designation was that meant it was available to anyone...
  4. Replies
    14
    Views
    992

    Field Controllers with Niagara AX and 4

    Hello,

    I was reading in this spyder programming thread and noticed a couple of people recommending to not use the spyder controllers.

    I've been AX certified since 2008 but have really never...
  5. Replies
    5
    Views
    633

    The TU for Controls gets you the ability to...

    The TU for Controls gets you the ability to configure and view the Tracer SC, and UC controllers (except for the UC800 which is a chiller controller). The RTUs (Trane) would just be a bacnet card,...
  6. Replies
    7
    Views
    608

    Gato, if you'll disable property filtering...

    Gato, if you'll disable property filtering (Tools/options>advanced tab>disable property filtering check box). Then you can point the setpoint control box to the property of relinquish default in the...
  7. Replies
    7
    Views
    608

    As discussed, there is not a way to write to or...

    As discussed, there is not a way to write to or control the PV of the AOP directly from the setpoint control box on the graphic. You can use a CPL behind the scene to make it work.

    If you want to...
  8. Replies
    8
    Views
    604

    That manual that you are referencing...

    That manual that you are referencing (RLC-SVU05A-E4) is for the RTWD/RTUD which are both water cooled models. You'll need to use techview to change the settings for the RTAC that you have. 159 is...
  9. Replies
    9
    Views
    519

    Do you have a continuous shield that is only...

    Do you have a continuous shield that is only grounded on one end? Not sure what else to check.
  10. Replies
    9
    Views
    519

    More than likely one of the TCI boards is bad. ...

    More than likely one of the TCI boards is bad. The only way that I know how to troubleshoot is to have someone on the roof, and someone watching the comm status on Summit. Go to each RTU one at a...
  11. Replies
    6
    Views
    937

    Klrogers, you are correct about the xif for the...

    Klrogers, you are correct about the xif for the loncard. I'm only familiar with using rover (flash download wizard) to send the appropriate config to the card. Perhaps you can use another Lon tool,...
  12. Replies
    6
    Views
    937

    No BCI-C on a CTV machine. The UC800 is the...

    No BCI-C on a CTV machine. The UC800 is the BACnet card. The BCI-C is only for RTA/CGA machines.
  13. Replies
    6
    Views
    937

    If you want an actual Comm interface, if it is...

    If you want an actual Comm interface, if it is not already installed, you'll have to have Trane install the card and 'bind' it to the controller with Kestrel View (I believe you might be able to do...
  14. I've seen this very same issue, its the BACnet...

    I've seen this very same issue, its the BACnet network number of the desert aire unit. Change it to anything other than 1 (which is what your BCU's should be by default). I had this happen with...
  15. Replies
    2
    Views
    506

    Yes, standard Trane is 10k type II.

    Yes, standard Trane is 10k type II.
  16. How are you sending the unit Occ/unocc commands...

    How are you sending the unit Occ/unocc commands if you're using a conventional Tsat?

    If you have an RTCI/LCI/BCI installed, the communicated value will take priority over anything wired locally. ...
  17. Replies
    8
    Views
    1,794

    I can't speak for the local office, but for me,...

    I can't speak for the local office, but for me, the next step would be to reach out to you and make you a verbal offer. Typically during the interview process they'll ask what your...
  18. Replies
    8
    Views
    1,794

    I can feel your pain. From my experience (I'm a...

    I can feel your pain. From my experience (I'm a hiring manager for a Trane office), it takes time. I'm sure each office/region has their own adaptations to the process. I will tell you, that we...
  19. Replies
    3
    Views
    612

    What version of Rover are you using? Anything...

    What version of Rover are you using? Anything older than 7.1 sp8(or around there) is only going to look for the device on the ZL domain. You can use your LN tool to commission the 580, and then set...
  20. I believe that it's been out for 5 years or so. ...

    I believe that it's been out for 5 years or so. You could say that it's the BACnet equivalent of the 580/581, so anything that you would use a 580/581 for you could also do with the UC600.
  21. Replies
    8
    Views
    1,292

    12/13 to 27 is the default safety circuit. It's...

    12/13 to 27 is the default safety circuit. It's looking for a N/C contact. You can verify by looking at the digital input parameters through the display.
  22. Replies
    7
    Views
    1,675

    The older CGAF is referred to as the "Intellipak"...

    The older CGAF is referred to as the "Intellipak" chiller since it uses the same UI. You can get a Lon card but not BACnet for that model of chiller. The BCI-C BACnet interface is only for the...
  23. Replies
    10
    Views
    2,557

    Ensure baud rate is correct as stated above. ...

    Ensure baud rate is correct as stated above. Ensure that the polarity is correct, and that the Link switch is set for BACnet and not IMC. Use the BACnet setup tool to change baud rate if necessary,...
  24. Replies
    2
    Views
    716

    Point mapping, or actually what points exist in a...

    Point mapping, or actually what points exist in a particular device. Also used to bind info from device to device, for example if you have to vav's that serve the large conference room, you can bind...
  25. Newton systems is correct. You just have to...

    Newton systems is correct. You just have to create an account.
  26. Nlutil should be able to modify the DSN as...

    Nlutil should be able to modify the DSN as scrooloose says. Nodeutil might also work, however I haven't used it in a long time. Both can be found for free online.
  27. Replies
    2
    Views
    857

    Depends on the version of Tracker. Since you say...

    Depends on the version of Tracker. Since you say "slightly newer two line display units", I'm gonna suggest that you will need hyperterminal. You'll need an RJ12 connector to serial (Trane PCM/UPCM...
  28. If it's 2002, it's a Reliatel board and not a...

    If it's 2002, it's a Reliatel board and not a UCP. Simply disconnect the BAYSENS from terminals 1,2,3,4 etc., hook up your new stat on the conventional thermostat connections R,Y,G,W etc. If there...
  29. Replies
    1
    Views
    496

    You want to use the Comm4 tool. Observe proper...

    You want to use the Comm4 tool. Observe proper polarity, and switch if necessary. I don't remember anything about the PCMCIA card, I've always used a Black Box Comm4 adaptor. If the polarity isn't...
  30. I would personally hw and not do the comm unless...

    I would personally hw and not do the comm unless it is in the spec. Regardless of mfg or protocol.
  31. Replies
    10
    Views
    1,769

    RTAC software is Techview which is free to any...

    RTAC software is Techview which is free to any and all to download. TU is not required or necessary to configure anything. It'll be very hard for you to purchase a copy of TU yourself. Your best...
  32. Replies
    1
    Views
    490

    I'll take a shot in the dark here. The...

    I'll take a shot in the dark here.

    The sensor accuracy is +/- .25C. Which means if your factory calibrated test instrument is measuring 19C, the sensor would read anywhere between 18.75C and...
  33. Replies
    2
    Views
    447

    You'll need Rover. I'm about 99% sure. There will...

    You'll need Rover. I'm about 99% sure. There will be some configuration available through Summit, but I don't believe that you can change the unit type.
  34. Replies
    13
    Views
    1,903

    You tell me. Is your JACE using DSN B? I'm...

    You tell me. Is your JACE using DSN B? I'm guessing it's not, but I don't work with the JACE platform. Making a config change in Rover won't change anything on the Lon network. You have to tell...
  35. Replies
    9
    Views
    1,902

    The +1.5 is shown in the VAV, it's called the...

    The +1.5 is shown in the VAV, it's called the "occupied offset". This makes the UC vav setpoint logic similar to the vv550, or Lon in general, where the "setpoint" is the median and the offset is...
  36. Replies
    13
    Views
    1,903

    If you don't know your domain, connect Rover,...

    If you don't know your domain, connect Rover, service pin a device. You'll see a message in Rover stating something like "a service pin press was received on a different domain than the discovery...
  37. Replies
    14
    Views
    2,259

    You should only need to command the Multi-State...

    You should only need to command the Multi-State Output - 7 for occupancy (1=occupied, 2=unoccupied). The other Binary Outputs that you mentioned are to enable/disable heating or cooling etc. not an...
  38. Replies
    8
    Views
    1,275

    I'm old fashioned, I still use the 0-10vdc/4-20ma...

    I'm old fashioned, I still use the 0-10vdc/4-20ma and dry contacts to VFD's so I don't connect comm to them unless specified in the job requirements. However, Trane TR200 drive= Danfoss VLT6000 if...
  39. I've never done this, however I believe that I...

    I've never done this, however I believe that I can provide some insight...

    Yes, you will need to create BACnet points inside the BCU. This is done by going to setup>inputs/outputs>"point type...
  40. Replies
    14
    Views
    2,259

    You don't need Trane to do anything. What is the...

    You don't need Trane to do anything. What is the unit reporting back for active status, occupancy, etc.? Do they match what you're sending? Are there any field installed safties (duct detector,...
  41. Replies
    2
    Views
    832

    You are correct, MWU is only available through...

    You are correct, MWU is only available through the local HI. The Day Time Warmup points should be available through the LCI-I, but I'm not certain of the exact point names.
  42. Replies
    2
    Views
    1,056

    It doesn't appear that serialspy is available for...

    It doesn't appear that serialspy is available for download. The download center link was hidden, however serialspy isn't listed.
  43. Thread: Trane Rover

    by roadgear16
    Replies
    3
    Views
    1,041

    Summit and Rover are two different programs. ...

    Summit and Rover are two different programs. Rover is a configuration tool for unit controllers (AHU's, vav's, programmable controllers, etc.), and can be password protected separately from Tracer...
  44. Hopefully they're not using the data to actually...

    Hopefully they're not using the data to actually bill the tenant. I know I'm not paying an electric bill from the utility company unless they can prove to me that it's accurate (unless they under...
  45. Replies
    8
    Views
    1,258

    You can not do bindings manually between the IPAK...

    You can not do bindings manually between the IPAK and the BCU.

    I typically leave the RTU econ decision in auto unless I'm trying to coordinate multiple RTU's. Depending on the configuration from...
  46. Replies
    7
    Views
    607

    It appears that there is a TOD calendar patch. ...

    It appears that there is a TOD calendar patch. Do you have access to mytranecontrols or comfortsite? I vaguely remember this issue but never experienced it for my self. Here is a description of...
  47. Replies
    7
    Views
    607

    Man, maybe I should have looked at a calendar...

    Man, maybe I should have looked at a calendar before I posted that.

    The date is correct, but the day is off one. I've never encountered that problem. What version of Summit are you running? ...
  48. Replies
    7
    Views
    607

    I'm not exactly sure what you're asking. The...

    I'm not exactly sure what you're asking. The picture shows the schedule for "1st and 2nd floor conf/lobby" for the weekdays M-F. It appears that you have optimal events starting at 7:00am and...
  49. Replies
    4
    Views
    604

    Are you referring to a software BO/AO withing...

    Are you referring to a software BO/AO withing Tracer Summit, or a physical BO/AO on the MP581?
    Overriding a Summit point, BO/AO, will only change it's value being sent to the MP581. You'll have...
  50. If it's a reliatel just remove the RTCI board and...

    If it's a reliatel just remove the RTCI board and connect conventional T-stat connections to the RTRM. You can use your controller to control the unit. No need to completely gut the unit. If it's...