  1. Replies
    1
    Views
    94

    AutoMatrix Emailing Alarms

    I just took over a site with 8 SageMax controllers and an AutoPilot/WebPilot front end. The customer would like to receive alarms via email. Can this be done? I haven't worked on AutoMatrix since the...
  2. Replies
    1
    Views
    178

    Station Tunnelling

    I have a customer that has 6 Jaces and a supervisor. The supervisor IP isn't exposed to the outside world, but the first Jace ( pre supervisor ) is. Can I use the exposed Jace to tunnel to another...
  3. Replies
    1
    Views
    139

    I found out that I need a USB to SD convertor to...

    I found out that I need a USB to SD convertor to properly back these up. Does anybody know the proper size SD card? I remember that older operating systems such as these will not recognize anything...
  4. Thread: AAM GC1

    by The Reaper
    Replies
    1
    Views
    134

    Here is the GC manual. You are going to need a...

    Here is the GC manual. You are going to need a copy of SoloPro and a 232/485 converter to do anything with this controller. If there is a Sage onsite, you can do everything through that. If you can...
  5. Replies
    9
    Views
    266

    Thanks for the replies. The customer wants this...

    Thanks for the replies. The customer wants this live on his graphics continually displaying usage in his central plant. This is Workbench 3.8.38.
  6. Johnson Controls does have a BACnet TEC that does...

    Johnson Controls does have a BACnet TEC that does this. The part number is TEC2613-4.
  7. Replies
    9
    Views
    266

    AX History Pie Chart

    I had a customer ask me if I could display several central plant Kw's in a pie chart on a px. Any idea if this is possible? Thanks in advance.
  8. Replies
    1
    Views
    139

    AAM Sage Backup

    I just took over a large AutoMatrix system with 7 Sages. I went to back them up with a box of floppy disks and 2 of the Sages had USB ports only. I figured out that it was seen as B drive, but...
  9. Replies
    10
    Views
    1,989

    Acronis has a universal restore feature that I...

    Acronis has a universal restore feature that I have used before with different hardware . It saved me a lot of headaches.
  10. Replies
    10
    Views
    1,989

    Check out a program called Acronis. It makes a...

    Check out a program called Acronis. It makes a mirror image of any machine and restores it to any other machine. Very easy to use.
  11. Replies
    6
    Views
    418

    The pass through is a component that allows you...

    The pass through is a component that allows you to use the NAE as a router to upload/download controllers. It needs to be installed separately on any machine that you will be using for this purpose.
  12. Check out Flexim. They are pricey but good. I...

    Check out Flexim. They are pricey but good. I just put a dual channel ultrasonic BTU meter on a chilled water loop and it is awesome! You can get all data via Modbus out of the meter.
  13. Replies
    2
    Views
    376

    That was it. Thanks!

    That was it. Thanks!
  14. Replies
    2
    Views
    376

    RTD Question

    I have an RTD that I need to reuse on an AHU. This reads the discharge temp on a gas burner. There is no part number in it. There is some info on the sensor that says RTD CO 1000 ohms @ 0 C 79457-1....
  15. Replies
    22
    Views
    1,576

    That wouldn't be in a public school in northern...

    That wouldn't be in a public school in northern Connecticut would it?
  16. Replies
    2
    Views
    288

    Sorry for the delayed response. That was it....

    Sorry for the delayed response. That was it. Thanks for the help!
  17. Replies
    2
    Views
    288

    Ax BACnet Export Write Fail

    I have a customer that is putting some demand based energy software into his facility and he wants to use it to command points in the Jace via BACnet IP. He can see all of my points and I have all...
  18. Replies
    0
    Views
    112

    Flexim AMD-7407 Modbus Integration

    Trying to figure out the registers on a Flexim AMD-7407 BTU meter. The factory was no help at all. Has anybody integrated to these before? Thanks in advance.
  19. Thanks

    Thanks
  20. You are correct. This is a Contemporary Controls...

    You are correct. This is a Contemporary Controls router. The problem is, I can't get it to scan into my device manager. I made sure I can get into the config through a browser, so I know the IP side...
  21. Alerton BACtalk Programming with IP to mstp Router

    Does anybody know if you can set up an IP to mstp router to be able to upload/download BACtalk controllers through Envision for BACtalk? I'm running a copy on my laptop with a valid key and I can't...
  22. Replies
    8
    Views
    409

    Sent you an email.

    Sent you an email.
  23. Replies
    8
    Views
    409

    I found the 1.8 disks. Is it on the auxiliary...

    I found the 1.8 disks. Is it on the auxiliary disk? What is the name of the program? Never throw anything away!!
  24. Replies
    8
    Views
    710

    You've got mail.

    You've got mail.
  25. Replies
    7
    Views
    433

    Got it! Thank You!

    Got it! Thank You!
  26. Replies
    8
    Views
    409

    I have a set of 1.8 utility disks somewhere in my...

    I have a set of 1.8 utility disks somewhere in my many piles of crapola. I'll look around and if I find it, I'll post it.
  27. Replies
    7
    Views
    433

    Thanks for the response. I like the way you...

    Thanks for the response. I like the way you think! Always striving to do things better. I'd like to see an example of the program object if possible. If not, I totally understand. I've been trying to...
  28. Replies
    7
    Views
    433

    BQL Information

    Does anybody have some good information on setting up BQL summaries? Thanks in advance.
  29. Replies
    8
    Views
    710

    Do you have access to the JCI FX site? One of the...

    Do you have access to the JCI FX site? One of the JCI FX guys posted a PWM module.
  30. Replies
    1
    Views
    215

    Never mind. Figured it out.

    Never mind. Figured it out.
  31. Replies
    1
    Views
    215

    Metasys GGT Question

    I have a customer that would like me to change all of the room names on the graphics and in the tree structure of the NAE's. How do I re bind the points in the GGT? I think they are using aliases....
  32. Replies
    1
    Views
    181

    Carrier Aquasnap BACnet Communications

    Does anybody have a list of BACnet points available for a 180 ton Aquasnap? I need to know what is writeable. Thanks in advance.
  33. Dave has a good point. I would go as far as to...

    Dave has a good point. I would go as far as to use a max version of 7 update 17. Personally, I would go with a new 30 and then you will have some support from your local supplier. What part of the...
  34. Replies
    6
    Views
    436

    Thanks for the replies! Very helpful information.

    Thanks for the replies! Very helpful information.
  35. Replies
    2
    Views
    258

    I just put a pop up binding on the bound label...

    I just put a pop up binding on the bound label and link it to that point's trend. FYI, I found a workaround in the Ax Community by using a drop down menu as the point label, then I can have multiple...
  36. The license is permanent and resides within the...

    The license is permanent and resides within the FX20, so it won't be locked. The Workbench tool is mostly complete, and you should be able to set it up in a browser. The reason that the 20 isn't...
  37. Replies
    2
    Views
    258

    AX Bound Label Pop Up Windows

    I have some bound labels that have pop up windows that show individual histories. My customer wants to have multiple pop up windows which he wants selectable from a drop down menu. I'm at a loss on...
  38. Replies
    6
    Views
    436

    Thanks for the reply. I don't know the version of...

    Thanks for the reply. I don't know the version of software or the exact model of the Tier 1 device. I just took over this facility and am trying to learn this system. I do know that there are KMD...
  39. Replies
    6
    Views
    436

    Figured it out. I needed to add a DALARM...

    Figured it out. I needed to add a DALARM statement to the program
  40. Replies
    6
    Views
    436

    KMC Total Control Alarms

    I'm trying to make a binary alarm email out to the in house guys. I have the input changing state properly and the class is set up just like all the other alarms that are working. The change of state...
  41. Is the network sensor set up for warmer/cooler...

    Is the network sensor set up for warmer/cooler adjust or setpoint? If it's set up for setpoint, that may be your issue. If you set it up for W/C, the program will spit out a writable point that you...
  42. Good point about the RAM issue.

    Good point about the RAM issue.
  43. Instead of writing to Present Value, try writing...

    Instead of writing to Present Value, try writing to 3113.
  44. Replies
    10
    Views
    1,819

    Wondering the same thing myself. I'm going to be...

    Wondering the same thing myself. I'm going to be doing an identical project in a few weeks.
  45. Replies
    29
    Views
    1,248

    I'm going to go out on a limb and say they sent...

    I'm going to go out on a limb and say they sent you 2 bad ones in a row. Wouldn't be the first time. This is a weird one. Please post the outcome. Good luck.
  46. Replies
    148
    Views
    4,852

    1) I Can Only Imagine 2) How Great Thou Art

    1) I Can Only Imagine
    2) How Great Thou Art
  47. Replies
    2
    Views
    231

    I believe that you need to configure the Site...

    I believe that you need to configure the Site Link for BACnet communications via hyper terminal with a 9 pin cable. There should be instructions in the manual on how to do this.
  48. Replies
    2
    Views
    383

    You've got mail.

    You've got mail.
  49. Replies
    14
    Views
    593

    Just go ahead and set up your station. When you...

    Just go ahead and set up your station. When you go live, if there is anything that doesn't jive, you can just do a discover on the LON network and match the right controller in the field to the right...
  50. Replies
    14
    Views
    593

    What type of field controllers do you have? You...

    What type of field controllers do you have? You will need to get the XIF files for them. I have built LON stations offline before. I have a LON PCMCIA card on my machine and I just discovered the...