Search:

Type: Posts; User: codewriter

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. http://www.mouser.com/ProductDetail/Chicago-Miniat...

    http://www.mouser.com/ProductDetail/Chicago-Miniature/7333/?qs=sGAEpiMZZMt82OzCyDsLFN8GhyN%252b0i6eWk%252biWWSw%2ftY%3d
  2. Replies
    9
    Views
    576

    shot us an email with the details sales AT hvacc...

    shot us an email with the details
    sales AT hvacc DOT net
  3. Its a RC flight sim program, the last bit where...

    Its a RC flight sim program, the last bit where the kid is running to it is doctored. The guy getting out of the plan is actually part of the flight sim program.
  4. Replies
    18
    Views
    1,736

    Gotcha! Now I understand where your going with...

    Gotcha! Now I understand where your going with that. Sometimes I am a little slow to catch on! haha :)
  5. Replies
    18
    Views
    1,736

    I'm taking it that your using some ASC controller...

    I'm taking it that your using some ASC controller that determines terminal load in that fashion? Why would you say less traffic? Terminal load, no matter what way your calculating it, is only one...
  6. Replies
    18
    Views
    1,736

    terminal load matches the damper position? Guess...

    terminal load matches the damper position? Guess that must be a VVT thing.

    I did totally miss that you were referring to VVT... doop...
  7. Replies
    18
    Views
    1,736

    crab, adjust static based on damper position, not...

    crab, adjust static based on damper position, not terminal load. If only one damper is 50% open and the rest of the dampers are less than 50%, start SLOWLY dropping your static until you are just...
  8. Replies
    33
    Views
    3,487

    thats no where near enough for what I expose in...

    thats no where near enough for what I expose in most cases. The Spyder can have somewhere in the neighborhood of 120 fields...
    Field = a single nv
    If your have a structured nv, and it contains 5...
  9. Replies
    33
    Views
    3,487

    Im talking about: being able to create...

    Im talking about:
    being able to create structured nv's (UCPT's, UNVT's)
    being able to create nv's that are part of a certain application, so when you drag your... say... dual pump lead lag app,...
  10. Replies
    33
    Views
    3,487

    the gfxProgram is certainly nice, wish it had...

    the gfxProgram is certainly nice, wish it had *some* of the features the spyder has, like the way you create network points, or I have just not figured it out well enough yet, only played around with...
  11. Replies
    18
    Views
    1,736

    Not always

    Not always
  12. Replies
    14
    Views
    1,511

    gotcha, I'm easily confused... :) Friday?...

    gotcha, I'm easily confused... :)

    Friday? Would that matter? Isn't working 7 days a week the norm? :)
  13. Replies
    14
    Views
    1,511

    :) Not sure what your quote is supposed to...

    :)

    Not sure what your quote is supposed to mean?

    Here is a cool tidbit, the spyder only really burns to EEPROM on power loss, so technically you could write to a nci all day long, then upon a...
  14. Replies
    14
    Views
    1,511

    https://www.lonmark.org/technical_resources/resour...

    https://www.lonmark.org/technical_resources/resource_files/LonMarkResourceFiles1302.exe

    A MUST have resource for anyone working with LON.
  15. I could do that with a spyder in about 30...

    I could do that with a spyder in about 30 minutes... :) Then expose SNVT's so the iLon can read/write from/to it. ALL tuning adjustments would be exposed as well, nothing would be left as "black...
  16. Replies
    14
    Views
    1,511

    an NCI could be a SNVT if its a SCPT and not a...

    an NCI could be a SNVT if its a SCPT and not a UCPT... correct? :D
  17. Replies
    18
    Views
    1,410

    We are part of the early access program, as well...

    We are part of the early access program, as well as the beta program, so we see things on niagara central that most do not. Its not a big secret, neither is things in 3.4, just look around NC and you...
  18. Replies
    18
    Views
    1,410

    do share

    do share
  19. Replies
    18
    Views
    1,410

    Its not beta yet, still just Early Access....

    Its not beta yet, still just Early Access. Actually, its been in Early Acess since 2/1/08, once it makes it to beta, then expect to wait a few more weeks until its released publicly.
  20. Replies
    18
    Views
    1,410

    That's ok Sys, not everyone can handle the...

    That's ok Sys, not everyone can handle the power... ;)
  21. Replies
    18
    Views
    1,410

    Its in 3.4, been playing around with it a little...

    Its in 3.4, been playing around with it a little bit in my spare time, certainly can already see the future potential.
  22. Replies
    7
    Views
    920

    Nobody?

    Nobody?
  23. Replies
    7
    Views
    920

    Distech EC12-A NV Timeout In Code

    Anyone know how to get a nv to timeout to be used in the code?
    Trying to init logic in the code if an nv times out.
    Thanks!
  24. Shoot me an email admin AT axframework DOT com

    Shoot me an email

    admin AT axframework DOT com
  25. No, I do not know whom your speaking of. If...

    No, I do not know whom your speaking of.

    If your into controls, computers, programming, etc... and have a good mechanical background, perhaps you should apply for a job... :)
    We are looking for...
  26. Are you doing all the distech programming and...

    Are you doing all the distech programming and such?
    I thought only MonaBT did distech in the area, I guess I was wrong.
  27. Replies
    8
    Views
    1,548

    haha, I like how the heat exchanger doubles as a...

    haha, I like how the heat exchanger doubles as a cooling coil... too funny
  28. Replies
    7
    Views
    1,074

    Sys is coming over to the dark side... he has...

    Sys is coming over to the dark side... he has just not admitted it yet... :D
    And I do not mean JCI...
  29. Where are you buying the Distech stuff from?

    Where are you buying the Distech stuff from?
  30. Replies
    3
    Views
    1,189

    That would make perfect sense. Thanks Will!

    That would make perfect sense. Thanks Will!
  31. Replies
    3
    Views
    1,189

    Trane ZN510 in MCCB FCU's

    I have the latest .xif (Version 07)
    Trying to figure out (off line) :(
    what the difference is between nvoSetpoint and nvoEffectSetpt

    Also, if anyone has a "cheat sheet" for the points, I would...
  32. Replies
    2
    Views
    715

    In 3.3, there is a sample program in the program...

    In 3.3, there is a sample program in the program palette that will do this.
  33. Replies
    39
    Views
    5,938

    Trane to start using Tridium AX ?

    I know its actually old news by now, but I did not see a topic here on it yet.
  34. Replies
    16
    Views
    1,613

    Use to run R6's and R1's, gave it up a few years...

    Use to run R6's and R1's, gave it up a few years ago though. I may have a custom chopper built sooner or later, or a off the shelf crusier.
    Its sad though, I got rid of my race bikes because I did...
  35. Replies
    13
    Views
    1,611

    Exactly tuncos... Orange and Yellow typically...

    Exactly tuncos... Orange and Yellow typically throw up a flag to most saying... "Oh My, dont touch that!"

    Red? I did not even know that was legal, even though I have seen a local company use Red...
  36. Replies
    16
    Views
    1,613

    For the right price, Vern will come to you... :)

    For the right price, Vern will come to you... :)
  37. Replies
    13
    Views
    1,611

    On a side note, I would recommend going with...

    On a side note, I would recommend going with Orange, it is not often used by other trades, and can make your life easier down the road if you find the need to trace it out in a ceiling, etc...
  38. Replies
    17
    Views
    2,808

    Crab, Re-read this entire post, your getting it...

    Crab, Re-read this entire post, your getting it backwards.

    4-20ma to 2-10vdc using a 500ohm res.. YES
    2-10vdc to 4-20ma using a 500ohm res.. NO
  39. Replies
    6
    Views
    593

    awww.... that's easy... YOU know how to do it......

    awww.... that's easy... YOU know how to do it... :)
  40. Replies
    17
    Views
    1,288

    Don't forget the resolution... VERY important! ...

    Don't forget the resolution... VERY important!

    8-bit will give you 255 steps
    10-bit will give you 1023 steps
    12-bit will give you 4095 steps
    etc... etc...
  41. Replies
    22
    Views
    1,439

    Hmmm... The first question I would ask is how are...

    Hmmm... The first question I would ask is how are you controlling the boiler in the first place? Enable/Disable? Stages? How Many? etc...
  42. Replies
    18
    Views
    3,164

    Whoops, sorry, you did say R2 and I assumed AX.

    Whoops, sorry, you did say R2 and I assumed AX.
  43. Replies
    18
    Views
    3,164

    Read the install manual, it shows you how.

    Read the install manual, it shows you how.
  44. Replies
    18
    Views
    3,164

    Sorry, but that is simply not true.

    Sorry, but that is simply not true.
  45. Replies
    95
    Views
    9,862

    Agreed, Lon is the flattest most flexible peer to...

    Agreed, Lon is the flattest most flexible peer to peer architecture there is in my oppinion. I think what Chris is trying to say is that with AX, you get one very powerful front end, much more...
  46. Replies
    17
    Views
    2,990

    Factory installed? Then it should be setup...

    Factory installed? Then it should be setup already, you may have to go into the chillers local HMI and enable it. Also double check the connections on the chillers local comm, I have seen them get...
  47. 1. You can't afford me... :) 2. It's too cold up...

    1. You can't afford me... :)
    2. It's too cold up there for me! :)

    Seriously though, good luck to finding someone to fit your needs. We are looking for GOOD installers... GOOD people are so hard...
  48. ouch... could'nt have picked a worse place to...

    ouch... could'nt have picked a worse place to mis-type that word!
    The irony... POR Grammer... :)
  49. Replies
    82
    Views
    25,599

    hahaha, you said "follow the directions"......

    hahaha, you said "follow the directions"... Imagine that!
  50. Replies
    10
    Views
    1,390

    IF you pay more for a JACE than a iLon, cut your...

    IF you pay more for a JACE than a iLon, cut your profit by the difference. Give the client a better product, they will be happier if you use it properly, and therefore you will end up with a win/win...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event