  1. Thread: Trainer

    by Matt Agee
    Replies
    3
    Views
    324

    Trainer

    These are some refrigeration trainers we are building at school. BCTC in Lexington, Kentucky. They have a high pressure switch, a low pressure switch, a TXV, a filter dryer, an sight glass, and a...
  2. Replies
    22
    Views
    1,035

    Put the Emerson and the Sporlan in series...

    Put the Emerson and the Sporlan in series together and then you'll catch the solids and the moisture too.:grin2:
  3. Replies
    19
    Views
    1,610

    I have a new project now ! Get some silicone...

    I have a new project now ! Get some silicone insulated wire and make some of those custom leads ! :)
  4. Replies
    62
    Views
    12,583

    Flexibility.

    Flexibility.
  5. Replies
    1
    Views
    361

    Service Manual Download ?

    I was on the section on here where you can download and print service manuals for ice machines the other day and I can't seem to find it now. Can anyone point me in the right direction ? Thanks.
  6. Replies
    62
    Views
    12,583

    Appion has great customer support as well. The...

    Appion has great customer support as well. The plunger on my core removal tool wasn't gripping the shraeder as it should. I called them and they immediately sent me a new one that worked great. No...
  7. Thread: Molex tool

    by Matt Agee
    Replies
    13
    Views
    1,305

    Radio Shack has those tools for a round $8.

    Radio Shack has those tools for a round $8.
  8. Replies
    6
    Views
    940

    Thanks, I'll check into the 375. I already have...

    Thanks, I'll check into the 375. I already have the 54II thermometer. I was hoping I could just have one tool that does it all so I didn't have to take up as much space in a small "go to" bag like...
  9. Replies
    6
    Views
    940

    Fluke Clamp Meter

    Does anyone know if fluke makes a clamp meter that measures both in-rush current as well as temperature ?
  10. Replies
    16
    Views
    2,728

    5 PSI acetylene and 7 PSI oxygen Is this with...

    5 PSI acetylene and 7 PSI oxygen
    Is this with the knob open or closed ?
  11. Replies
    26
    Views
    2,355

    Thanks guys !

    Thanks guys !
  12. Replies
    26
    Views
    2,355

    Nitrogen tank pressure ?

    How many PSI should a newly filled 40 cubic foot nitrogen tank have on it ? I just exchanged one and it has 2000psi. is that about right ? Thanks in advance.
  13. Replies
    33
    Views
    1,510

    I should be out that way this weekend. I'll try...

    I should be out that way this weekend. I'll try to get some pressures, SH SC then.
  14. Replies
    20
    Views
    1,594

    5 = CAN = COMMON 2 = SHE = START 1 = RUN = RUN...

    5 = CAN = COMMON
    2 = SHE = START
    1 = RUN = RUN
    A GOOD WAY TO REMEMBER :grin2:
  15. Replies
    33
    Views
    1,510

    It's not short cycling. It runs about the normal...

    It's not short cycling. It runs about the normal amount of time to satisfy the thermostat. The only complaint is the electric bill. At this point I'm not sure if the problem is the unit or not. ...
  16. Replies
    33
    Views
    1,510

    Haven't checked any pressures or SH/SC but it is...

    Haven't checked any pressures or SH/SC but it is cooling/heating ok. Just the electricity usage issue on the bill is the only complaint.
  17. Replies
    33
    Views
    1,510

    Both

    Both
  18. Replies
    59
    Views
    7,096

    http://http://youtu.be/5JLveeyYPEE Hilmor makes...

    http://http://youtu.be/5JLveeyYPEE
    Hilmor makes this one.
  19. Replies
    33
    Views
    1,510

    Their complaint is that the electric bill is...

    Their complaint is that the electric bill is getting out of hand and I am trying to identify the cause.
  20. Replies
    33
    Views
    1,510

    What meter would be good to capture in-rush...

    What meter would be good to capture in-rush current ? I know the Fieldpiece SC56 and the Amprobe ACD-51 NAV both have in-rush measuring capability. I just wondered if anyone has used any and which...
  21. Replies
    33
    Views
    1,510

    Thanks guys ! I guess I'm within tolerance then...

    Thanks guys ! I guess I'm within tolerance then at 30.
  22. Replies
    33
    Views
    1,510

    Condensing unit In-rush AMP. draw

    I have a Lennox M/N 10HPB18-14P SERIAL# 5805F24778. R22

    COMPRESSOR RLA 8.6
    LRA 49
    FAN MOTOR FLA 1.1
    FAN MOTOR 1/6 HP

    This unit is drawing around 30 amps. on startup and around 5 after it...
  23. Replies
    5
    Views
    587

    Thanks for the reply. :)

    Thanks for the reply. :)
  24. Thread: Resistors

    by Matt Agee
    Replies
    10
    Views
    860

    Ebay has these - 2W 1W 1/2W Resistor Assortment...

    Ebay has these - 2W 1W 1/2W Resistor Assortment Kit 2 Watts 1 Watt - $18.33 including shipping.
  25. Replies
    5
    Views
    587

    Replacing lost compressor oil ?

    I'm a first year HVAC student and I was wondering something. When refrigerant is recovered from a system, a small amount
    oil is taken out each time a recovery is done, right ? So, that being...
  26. Replies
    59
    Views
    5,028

    I liked this (the Bosch 12volt impact). Compact...

    I liked this (the Bosch 12volt impact). Compact but powerful. Just bought a new one. :)
  27. I get mine at O'Reilly's. $8.99 per quart for...

    I get mine at O'Reilly's. $8.99 per quart for Robinair brand.
  28. Replies
    6
    Views
    992

    They are for oxy-acetylene.

    They are for oxy-acetylene.
  29. Replies
    7
    Views
    698

    414471

    414471
  30. Replies
    6
    Views
    992

    Thanks for all the replies. I think I'll try...

    Thanks for all the replies. I think I'll try them. They look like they would work good on reversing valves, TXVs, and that sort of thing.
  31. Replies
    6
    Views
    992

    Smith little torch. Anyone tried it ?

    I was thinking about purchasing one of these and I was wondering if anyone has tried them and if they liked them.

    Smith Quickbraze Outfit Little Torch 23 5005A | eBay
  32. Replies
    29
    Views
    2,481

    I called Appion when mine didn't work just right...

    I called Appion when mine didn't work just right and they sent new ones right away. No questions asked. Great customer support. Oh yea, they did ask one question...my address so they could send...
  33. "NOTE: There is a mesh screen in the YJ brand of...

    "NOTE: There is a mesh screen in the YJ brand of pumps to prevent debris entering the rotaries. Make good practice to remove and clean screen annually. It is fine mesh and clogs fairly often."
    ...
  34. Replies
    10
    Views
    1,158

    I have a new 8 cfm super evac. YJ and it will...

    I have a new 8 cfm super evac. YJ and it will only pull down to 160 microns on a recovery tank. Maybe the guage on it is faulty as well.
  35. YELLOW JACKET 8CFM SUPER EVAC. SCREEN/FILTER LOCATION ?

    I Have a Yellow Jacket 8 cfm super evac. Does anyone know where the mesh filter is located ? Thanks.
  36. Replies
    13
    Views
    2,705

    The more connections and joints you have the more...

    The more connections and joints you have the more chances for leaks.
  37. Replies
    16
    Views
    2,728

    Thanks for the insight folks ! All input is...

    Thanks for the insight folks ! All input is appreciated.
  38. Replies
    16
    Views
    2,728

    The torch model number is WH270FC-V.

    The torch model number is WH270FC-V.
  39. Replies
    16
    Views
    2,728

    Oxy-acetylene brazing tip

    I have a small Victor oxy-acetylene set (MC) and I have been told rosebud style tip is the best. can anyone give me a specific model number or opinions on the best tip to use for 3/8-3/4" line sets ?...
  40. I sure will. I've noticed many of them show the...

    I sure will. I've noticed many of them show the same operation but use totally different procedures. Thanks for the welcome !
  41. Replies
    21
    Views
    2,156

    Thanks for all of the replies. I really like the...

    Thanks for all of the replies. I really like the idea of putting a filter in line to the tank. I really love this forum. I've already learned a lot from it by just reading different threads.
  42. Thread: Nylog

    by Matt Agee
    Replies
    6
    Views
    935

    I hate to reveal my ignorance but what is...

    I hate to reveal my ignorance but what is "residual MO or AB" ?
  43. Replies
    21
    Views
    2,156

    Thanks much for the reply ! That's what I'll do...

    Thanks much for the reply ! That's what I'll do then.
  44. Replies
    21
    Views
    2,156

    Storage of a recovery tank ?

    Would it hurt anything to store an empty recovery cylinder under a vacuum ? Say 250-500 microns. Or should it be stored only at atmospheric pressure ? Any input is appreciated. I thought if I...
  45. Thread: vacuum hose

    by Matt Agee
    Replies
    66
    Views
    7,380

    I recently purchased two NRP 1/2" heavy duty...

    I recently purchased two NRP 1/2" heavy duty hoses. They have a 1/4 on one end and 3/8 on the other. They don't come with shraeder valve depressors. I put a brass tee with two 3/8 male flare...
  46. Eager to learn and about to start HVACR school

    My name is Matt Agee. I live in Richmond, Kentucky. I have recently purchased about $6,000 worth of the best new HVAC tools money can buy. I guess you could say I'm addicted to tools. I am...
Results 1 to 46 of 57